Sökning: onr:"swepub:oai:research.chalmers.se:cb30f97e-d171-4072-9510-06d9c366eb18" >
Dynamic Range Expan...
Dynamic Range Expansion of the C-Reactive Protein Quantification with a Tandem Giant Magnetoresistance Biosensor
-
- Meng, Fanda, 1987 (författare)
- Shandong Qianfoshan Hospital,Chalmers tekniska högskola,Chalmers University of Technology
-
- Zhang, Lei (författare)
- Chinese Academy of Sciences,Dongguan Bosh Biotechnologies, Ltd.
-
- Huo, Weisong (författare)
- Dongguan Bosh Biotechnologies, Ltd.
-
visa fler...
-
- Lian, Jie (författare)
- People's Public Security University of China
-
- Jesorka, Aldo, 1967 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Shi, Xizeng (författare)
- Dongguan Bosh Biotechnologies, Ltd.
-
- Gao, Yunhua (författare)
- Chinese Academy of Sciences
-
visa färre...
-
(creator_code:org_t)
- 2021-05-07
- 2021
- Engelska.
-
Ingår i: ACS Omega. - : American Chemical Society (ACS). - 2470-1343. ; 6:19, s. 12923-12930
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
https://pubs.acs.org...
-
https://research.cha...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In this study, we report a convenient analytical method for a full-range quantification of the C-reactive protein (CRP), a blood biomarker of infection and cardiovascular events. We determine CRP over the entire diagnostically relevant concentration range in undiluted human blood serum in a single test, using a tandem giant magnetoresistance (GMR) sensor. The tandem principle combines a sandwich assay and a competitive assay, which allows for the discrimination of the concentration values resulting from the multivalued dose-response curve ("Hook"effect), which characterizes the one-step sandwich assay at high CRP concentrations. The sensor covers a linear detection range for CRP concentration from 3 ng/mL to 350 μg/mL, the detection limit (s/n = 3) is 1 ng/mL. The prominent features of the chip-based method are its expanded dynamic range and low sample volume (50 μL), and the need for a short measurement time of 15 min. These figures of merit, in addition to the low detection limit equal to the established assay instrumentation, make it a viable candidate for use in point-of-care diagnostics.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas