SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:d1748b55-9647-4f85-8570-0e88f0b07d70"
 

Sökning: onr:"swepub:oai:research.chalmers.se:d1748b55-9647-4f85-8570-0e88f0b07d70" > Circulating Current...

Circulating Current Suppression Strategies for D-STATCOM Based on Modular Multilevel Converters

Pereira, H. A. (författare)
Universidade Federal de Minas Gerais,Universidade Federal de Vicosa,Federal University of Viçosa
Haddioui, M. R. (författare)
Aalborg Universitet,Aalborg University
de Oliveira, L. O. M. (författare)
Universidade Federal de Vicosa,Federal University of Viçosa
visa fler...
Mathe, L. (författare)
Aalborg Universitet,Aalborg University
Bongiorno, Massimo, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Teodorescu, Remus, 1965 (författare)
Aalborg Universitet,Aalborg University
visa färre...
 (creator_code:org_t)
ISBN 9781479987795
2015
2015
Engelska.
Ingår i: 2015 Ieee 13th Brazilian Power Electronics Conference and 1st Southern Power Electronics Conference (Cobep/Spec). - 9781479987795 ; , s. 1-6
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • This work focuses on the circulating current measurement of a STAtic synchronous COMpensator (STATCOM) based on Modular Multilevel Converter (MMC). In a Delta (D) connected MMC-based STATCOM configuration the currents are divided in two parts: grid currents and circulating currents. The latest circulates between legs and has no direct impact on the output current, but it has a third harmonic component, which causes problems in the circulating current control. Thus, this work evaluates three circulating current measurement strategies, with focus on the converter characteristics improvement, such as losses reduction. A classical strategy is compared with other two strategies using a Second Order Generalized Integrator (SOGI) structure. The first proposed strategy eliminates the third harmonic from the circulating current and the second detects the fundamental component of the circulating current eliminating the other harmonic components. Simulated and experimental results show that this strategies achieve reduction in the circulating current, and consequently reduction in the STATCOM losses.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

STAtic synchronous COMpensator (STATCOM)
Voltage-Source Converters (VSCs)
performance
Circulating current
pwm statcom
design
Engineering
Modular Multilevel Converters (MMCs)
cascade converter
Energy & Fuels

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy