Survey of radiator temperatures in buildings supplied by district heating

Jangsten, Maria, 1989 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kensby, Johan, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Dalenbäck, Jan-Olof, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Trüschel, Anders, 1970 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2017
2017
Engelska.
Ingår i: Energy. - : Elsevier BV. - 0360-5442. ; 137, s. 292-301
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In order to maintain the competitiveness and improve the environmental performance of district heating in the future, it is essential to transition to lower operating temperatures than those of current third-generation district heating systems. Heat demands are expected to decrease as buildings become more energy efficient, and new types of heat sources are likely to be integrated. Therefore, future supply and return temperatures of 50–55 °C and 20–30 °C, have been suggested for the fourth-generation district heating systems. Previous studies on radiator temperatures are limited to the radiator's design conditions for modeling purposes, and there are no published studies that have established what the actual supply and return temperatures in radiator systems are. The purpose of this study is therefore to investigate what the temperatures are and to provide statistics on the radiator temperatures on the secondary side of district heating systems. The results, incorporating data from 109 radiator systems located in Gothenburg's district heating system, showed that the average supply and return temperatures for design outdoor temperature ?16 °C are 64 °C and 42 °C, respectively. For an outdoor temperature of 5 °C or more all radiator systems had supply temperatures of 55 °C or less. The results also showed that radiator systems with a large radiator heat transfer area had the largest potential for lower radiator operating temperatures, as indicated by the normalized radiator constant and the specific space heating demand.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Radiator constant
Radiator temperatures
4GDH
Low-temperature district heating

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy