A Novel Approach for Estimation of Electrical Bioimpedance: Total Least Square

Seoane Martinez, Fernando, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,Högskolan i Borås
Lindecrantz, Kaj, 1951 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,Högskolan i Borås
 (creator_code:org_t)
2007
2007
Engelska.
Ingår i: International Federation for Medical and Biological Engineering Proceedings. - 1680-0737. ; 17, s. 190-193, s. 190-193
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • There are several methods used for AC-impedance estimation in Electrical Bioimpedance measurements. In this paper we propose a novel method for digital estimation of electrical impedance based in the Total Least Square (TLS) technique and we carry out a performance comparison between the proposed method and the typical Digital Sine Correlation (DSC) method. The TLS method has been implemented using the Singular Value Decomposition approach and the performance of both methods have been compared in terms of robustness against noise and size of the data set. The results indicate that the TLS method shows a better performance for impedance estimation than the DSC with reduced set of measurement samples and high SNR levels, while its performance worsen for increasing number of samples and decreasing SNR. The DSC method exhibits a better robustness against noise, especially for increasing the number of data samples. The main observed advantage of the TLS method is that it suffers from less mathematical constrains than the DSC method, and since the noise levels in bioimpedance applications are not expected to be very high we conclude that the TLS method is a good choice as impedance estimator.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
NATURVETENSKAP  -- Matematik -- Matematisk analys (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Mathematical Analysis (hsv//eng)

Nyckelord

Digital Impedance Estimation
Sine Correla-tion
Total Least Square.
Bioimpedance

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy