SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:f82eee47-6938-4d2b-b6aa-57af95374094"
 

Sökning: onr:"swepub:oai:research.chalmers.se:f82eee47-6938-4d2b-b6aa-57af95374094" > Validation of IMU a...

Validation of IMU against optical reference and development of an open source pipeline: Proof of concept case report in transfemoral amputation fitted with a Percutaneous Osseointegrated Implant

Ahmed, Kirstin, 1974 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Taheri, Mohammad Javad, 1994 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Weygers, Ive (författare)
Friedrich-Alexander-Universität Erlangen Nurnberg (FAU)
visa fler...
Ortiz Catalan, Max Jair, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Journal of NeuroEngineering and Rehabilitation. - 1743-0003.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Systems that capture motion under laboratory conditions limit validity in real-world environments. Mobile motion capture solutions such as Inertial Measurement Units (IMUs) can progress our understanding of "real" human movement. IMU data must be validated in each application to interpret with clinical applicability; this is particularly true for diverse populations. Our IMU analysis method builds on the OpenSim IMU Inverse Kinematics toolkit integrating the Versatile Quaternion-based Filter and incorporates realistic constraints to the underlying biomechanical model. We validate our processing method against the reference standard optical motion capture in participants with transfemoral amputation fitted with a Percutaneous Osseointegrated Implant (POI) and without amputation. Results Average RMSE between the two systems from the amputated participant (TFA) on the amputated and the intact sides were 2.35 ° (IQR = 1.45 °) and 3.59 ° (IQR = 2.00 °) respectively. Equivalent results without amputation (WA) were 2.26 ° (IQR = 1.08 °). Joint level average RMSE between the two systems from the TFA ranged from 1.66 ° to 3.82 ° and from 1.21 ° to 5.46 ° WA. In plane average RMSE between the two systems from the TFA ranged from 2.17 ° (coronal) to 3.91 ° (sagittal) and from 1.96 ° (transverse) to 2.32 ° (sagittal) WA. CMC results between the two systems in the TFA ranged from 0.74 to > 0.99 and from 0.72 to > 0.99 WA and resulted in ‘excellent’ similarity in each data set average, in every plane and at all joint levels. Normalized RMSE between the two systems from the TFA ranged from 3.40 % (knee level) to 54.54 % (pelvis level) and from 2.18 % to 36.01 % WA. Conclusions We offer a modular processing pipeline that enables the addition of extra layers, facilitates changes to the underlying biomechanical model, and can accept raw IMU data from any vendor. We successfully validate the pipeline using data, for the first time, from a TFA participant using a POI. We have proved our hypothesis that by using this novel pipeline we can validate IMU motion capture data, to a clinically acceptable degree.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ahmed, Kirstin, ...
Taheri, Mohammad ...
Weygers, Ive
Ortiz Catalan, M ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Journal of Neuro ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy