SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:slubar.slu.se:64840"
 

Sökning: onr:"swepub:oai:slubar.slu.se:64840" > Ligation of the spe...

Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer : feasibility and long-term follow-up study

Höglund, Odd (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Ingman, Jessica (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,University Animal Hospital
Södersten, Fredrik (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Inst för biomedicin och veterinär folkhälsovetenskap,Department of Biomedical Science and Veterinary Public Health
visa fler...
Hansson, Kerstin (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Lagerstedt, Anne-Sofie (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
visa färre...
 (creator_code:org_t)
 
Springer Science and Business Media LLC, 2014
2014
Engelska.
Ingår i: BMC Research Notes. - : Springer Science and Business Media LLC. - 1756-0500. ; 7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigate the feasibility of ligating the spermatic cord with the device, its biocompatibility and long-term resorption in dogs.  Results: The device was made of a block co-polymer (glycolide and trimethylene carbonate), manufactured by injection moulding and consisted of a flexible band running through a case with a locking mechanism. Ten devices were tested for ligation of the spermatic cords in five dogs admitted for routine neutering. The dogs were monitored by physical examination and ultrasonography of the site of ligation, area of spermatic cord and medial iliac lymph nodes regularly until no hyperechoic remnants of the device or acoustic shadowing or local tissue reactions were observed. Haemostasis of the spermatic cords was achieved with the devices. On ultrasonography the devices were seen as hyperechoic structures for 2 months after neutering causing acoustic shadowing for 1 month. The dogs were monitored for 3 - 5 months after surgery. Gradual decrease in echogenicity and final disappearance of the hyperechoic structures suggested resorption. Macroscopic and histological post mortem examinations were performed in one dog at 3 months after surgery. Post mortem examination showed a tissue reaction of a suture granuloma that was restricted in extent at site of the device.  Conclusions: The results of this pilot study suggest biocompatibility and indicate that ligation of the spermatic cord is feasible with the device.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy