SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "L773:0780375254 "

Search: L773:0780375254

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Akke, Magnus (author)
  • Fault classification for distance protection
  • 2002
  • In: IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. - 0780375254 ; 2, s. 835-839
  • Conference paper (peer-reviewed)abstract
    • This paper presents an overview of power system fault classification methods and challenges. It also contains some ideas about structured testing.
  •  
2.
  • Akke, Magnus, et al. (author)
  • Phasor measurement applications in Scandinavia
  • 2002
  • In: IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. - 0780375254 ; 1, s. 480-484
  • Conference paper (peer-reviewed)abstract
    • There is a great potential for phasor measurement applications in Scandinavia, mainly due to the long distance power transmission and limited transmission capacity expansion possibilities. Smart control, based on phasor measurements, can be used as an alternative to additional transmission lines, to increase power transmission capacity. Also the matter of damping is more and more becoming a key issue, since load is slowly increasing and the de-regulation has caused an increase in fast and unexpected changes of generation dispatch and load flow. In Sweden an extensive optic fiber communication network has been installed along the transmission lines (mainly inside and around the ground wire at the top of the tower). Two test recordings have been performed to show the capability of synchronized phasor measurements. In Iceland phasors could be suitable input signal to damping equipment designed to mitigate system wide oscillations. An other test was made to see the "natural oscillations" between Sweden and Denmark during a 2 week period of very weak connection between the two areas. The Swedish railway is to a large extent fed by a 130 kV 16 2/3 Hz transmission line (/spl sim/1000 km). Transformers and converters then feed the contact line and the trains. Static phasor information would be a good input signal candidate to optimize the parallel converter operation.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
conference paper (2)
Type of content
peer-reviewed (2)
Author/Editor
Akke, Magnus (2)
Karlsson, D (1)
University
Lund University (2)
Language
English (2)
Research subject (UKÄ/SCB)
Engineering and Technology (2)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view