SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "L773:2631 6439 "

Search: L773:2631 6439

  • Result 1-10 of 15
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Monje, Alberto, et al. (author)
  • Strategies for implant surface decontamination in peri-implantitis therapy
  • 2022
  • In: International journal of oral implantology. - : QUINTESSENCE PUBLISHING CO INC. - 2631-6420 .- 2631-6439. ; 15:3, s. 213-249
  • Research review (peer-reviewed)abstract
    • Peri-implantitis is an infectious disease that leads to progressive bone loss. Surgical therapy has been advocated as a way of halting its progression and re-establishing peri-implant health. One of the most challenging but crucial tasks in the management of peri-implantitis is biofilm removal to achieve reosseointegration and promote the reduction of peri-implant pockets. A wide var-iety of strategies have been used for implant surface decontamination. Mechanical means have been demonstrated to be effective in eliminating calculus deposits and residual debris; however, the presence of undercuts and the grooves and porosities along the roughened implant surface make it difficult to achieve an aseptic surface. In conjunction with mechanical measures, use of chemical adjuncts has been advocated to dilute bacterial concentrations, destroy the bacteria's organic components and eliminate endotoxins. Pharmacological adjuncts have also been recommended to diminish the bacterial load. Other strategies, such as use of lasers, implantoplasty and electrolysis, have been suggested for implant surface decontamination to promote predictable clinical and radiographic outcomes.
  •  
2.
  • Cannizzaro, Gioacchino, et al. (author)
  • Immediate loading of one (fixed-on-1) versus two (fixed-on-2) implants placed flapless supporting mandibular screw-retained cross-arch fixed prostheses: 10-month results from an explanatory randomised controlled trial.
  • 2019
  • In: International journal of oral implantology (New Malden, London, England). - 2631-6439. ; 12:1, s. 89-102
  • Journal article (peer-reviewed)abstract
    • To evaluate the outcome of one (fixed-on-1, Fo1) versus two (fixed-on-2, Fo2) implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Twenty patients with edentulous or to be rendered edentulous mandibles were randomised to the Fo1 group (10 patients who received three intraforaminal implants but only the mesial implant was actually loaded) and to the Fo2 group (10 patients who received two intraforaminal implants) according to a parallel-group design. To be immediately loaded implants had to be inserted with a minimum torque of 60 Ncm. Outcome measures were prosthesis and implant failures, complications and patient satisfaction for function and aesthetics evaluated up to 10 months post-loading.Flaps were raised in three patients of the Fo1 group and one of the Fo2 group. Two prostheses in each group were delayed loaded at 2 and 3 months, because implants could not be inserted with a torque superior to 60 Ncm. Patients of the Fo2 group received prostheses with 12 teeth whereas Fo1 patients with 8 or 10 teeth. Ten months after loading no drop-out or implant failure occurred, but one Fo2 prosthesis had to be remade because the patient complained it was too short (risk difference = 0.1; 95% CI: -0.19 to 0.40; Fisher's exact test P = 1.000). Three patients were affected by complications in each group (risk difference = 0.0; 95% CI: -0.359 to 0.359; Fisher's exact test; P = 1.000). There were no statistically significant differences for prosthetic failures and complications between groups. Four months after loading, patients of the Fo1 group were less satisfied for function than those of the Fo2 group (difference between the medians [Hodges-Lehmann estimation] = 1; 95% CI: 0 to 2; P = 0.043). No differences were observed for aesthetics (difference between the medians [Hodges-Lehmann estimation] = 0; 95% CI: -1 to 0; P = 0.481), and two Fo1 patients would not undergo the same procedure again (difference in proportions: 0.2; 95% CI: -0.11 to 0.51; P = 0.474).Preliminary results suggest that immediately loaded cross-arch screw-retained fixed prostheses with 8 to 10 teeth can be supported by only one dental implant at least up to 10 months post-loading; however, the clinical application and usefulness of such a procedure remains questionable.
  •  
3.
  •  
4.
  • Esposito, Marco, 1965, et al. (author)
  • Short implants versus longer implants in vertically augmented atrophic mandibles: A systematic review of randomised controlled trials with a 5-year post-loading follow-up.
  • 2019
  • In: International journal of oral implantology (New Malden, London, England). - 2631-6439. ; 12:3, s. 267-280
  • Journal article (peer-reviewed)abstract
    • To compare the clinical outcome of fixed prostheses supported by 4- to 8-mm-long implants with prostheses supported by longer implants placed in vertically augmented atrophic mandibles after a follow-up of 5 years in function.The Cochrane Central Register of Controlled Trials (CENTRAL) and MEDLINE were searched up to 1st September 2018 for randomised controlled trials (RCTs) with a follow-up of at least 5 years in function comparing fixed prostheses supported by 4- to 8-mm-long implants with prostheses supported by longer implants placed in vertically augmented atrophic mandibles. Outcome measures were prosthesis failure, implant failures, augmentation procedure failures, complications, and peri-implant marginal bone level changes. Screening of eligible studies, assessment of the risk of bias and data extraction were conducted in duplicate and independently by two review authors. The statistical unit of the analysis was the prosthesis. Results were expressed as random-effects models using mean differences for continuous outcomes and risk ratios (RR) for dichotomous outcomes with 95% confidence intervals (CIs).Four eligible RCTs that included originally 135 patients were included. Two RCTs had a parallel-group design and two a split-mouth design. Short implants were 5.0 to 6.6 mm long and were compared with longer implants placed in posterior mandibles augmented with interpositional blocks of bone substitutes. All trials were judged at unclear risk of bias. Twelve (14%) bone augmentation procedures failed to achieve the planned bone height to allow placement of implants with the planned length. Five years after loading, 28 patients (21%) had dropped out from the four RCTs. There were no differences for patients having prosthesis (RR = 1.46; 95% CI: 0.52 to 4.09; P = 0.47; I2 = 0%) or implant (RR = 1.00; 95% CI: 0.31 to 3.21; P = 1.00; I2 = 0%) failures between the two interventions, but there were more patients experiencing complications (RR = 4.72; 95% CI: 2.43 to 9.17; P < 0.00001; I2 = 0%) and peri-implant marginal bone loss (mean difference = 0.60 mm; 95% CI: 0.36 to 0.83; P < 0.00001; I2 = 45%) at longer implants in augmented bone.Five years after loading, prosthetic and implant failures were similar between the two interventions, but complications and peri-implant marginal bone loss were higher and more severe at longer implants placed in vertically augmented mandibles. Larger trials and longer follow-ups up to 10 years after loading are needed to confirm or reject the present preliminary findings. However in the meantime short implants could be the preferable option.
  •  
5.
  • Felice, Pietro, et al. (author)
  • Five-year results from a randomised controlled trial comparing prostheses supported by 5-mm long implants or by longer implants in augmented bone in posterior atrophic edentulous jaws.
  • 2019
  • In: International journal of oral implantology (New Malden, London, England). - 2631-6439. ; 12:1, s. 25-37
  • Journal article (peer-reviewed)abstract
    • To evaluate whether 5-mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10-mm long implants in posterior atrophic jaws.Fifteen patients with bilateral atrophic mandibles (5 to 7 mm bone height above the mandibular canal) and 15 patients with bilateral atrophic maxillae (4 to 6 mm bone height below the maxillary sinus), and bone thickness of at least 8 mm, were randomised according to a split-mouth design to receive one to three 5-mm short implants or at least 10-mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after another 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes.In five augmented mandibles the planned 10-mm long implants could not be placed and shorter implants (7.0 and 8.5 mm) had to be used instead. Five years after loading, six patients, five treated in the mandible and one in the maxilla, dropped out. Three prostheses (one mandibular and two maxillary) failed in the short-implant group versus none in the long-implant group. In mandibles one long implant failed versus two short implants in one patient. In maxillae one long implant failed versus three short implants in two patients. There were no statistically significant differences in implant (n = 26; P = 1.00, difference = 3.85%, 95% CI: -12.95% to 20.64%) and prosthetic (n = 26; P = 0.250, difference = 11.54%, 95% CI: -0.74% to 23.82%) failures. Eleven patients had 16 complications at short implants (one patient accounted for six complications) and 12 patients had 14 complications at long implants. There were no statistically significant differences in complications (n = 28; P = 1.00, difference = -3.57%, 95% CI: -30.65% to 23.51%). Five years after loading, patients with mandibular implants lost on average 1.72 mm at short implants and 2.10 mm at long implants of peri-implant marginal bone. This difference was statistically significant (difference = 0.37 ± 0.43 mm; 95% CI: 0.07 to 0.68 mm; P = 0.022). In maxillae, patients lost on average 1.31 mm at short implants and 1.79 mm at long implants. This difference was statistically significant (difference = 0.48 ± 0.43 mm; 95% CI: 0.22 to 0.74 mm; P = 0.002).Five years after loading, 5-mm short implants achieved similar results to longer implants in augmented bone. The choice of short implants might be preferable to vertical bone augmentation, especially in mandibles, since the treatment is faster and cheaper.
  •  
6.
  • Felice, Pietro, et al. (author)
  • Posterior atrophic jaws rehabilitated with prostheses supported by 6-mm-long 4-mm-wide implants or by longer implants in augmented bone. Five-year post-loading results from a within-person randomised controlled trial.
  • 2019
  • In: International journal of oral implantology (New Malden, London, England). - 2631-6439. ; 12:1, s. 57-72
  • Journal article (peer-reviewed)abstract
    • To evaluate whether 6-mm-long by 4-mm-wide dental implants could be an alternative to implants at least 10-mm long placed in bone augmented with bone substitutes in posterior atrophic jaws.A total of 20 patients with bilateral atrophic mandibles and 20 patients with bilateral atrophic maxillae, having 5 to 7 mm of bone height below the maxillary sinus or 6 to 8 mm above the mandibular canal, had their sides of the jaws randomly allocated according to a split-mouth design. They were allocated to receive one to three 6-mm-long and 4-mm-wide implants, or implants at least 10-mm long in augmented bone by two different surgeons in different centres. Mandibles were vertically augmented with interpositional equine bone blocks and resorbable barriers, and implants were placed 3 months later. Maxillary sinuses were augmented with particulated porcine bone via a lateral window and implants were placed simultaneously. All implants were submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive prostheses were delivered. Outcome measures were prosthesis and implant failures, any complication and radiographic peri-implant marginal bone level changes. The follow-up was 5 years after loading for all patients.Eight patients (five treated in mandibles and three in maxillae) dropped out before the 5-year post-loading follow-up. Four short implants (two maxillary and two mandibular) affected by peri-implantitis failed together with their prostheses versus three mandibular prostheses which could not be placed on implants at least 10-mm long due to graft failures; one was associated with the loss of three implants because of infection. There were no statistically significant differences in implant (P = 1.0) and prosthesis failures (P = 1.0). In total, 19 complications occurred in 14 patients at augmented sites versus five complications in four patients with 6-mm-long implants (P = 0.118). More complications occurred at grafted sites both in mandibles (P = 0.727), and maxillae (P = 0.063), although the differences were not statistically significant. In mandibles, patients with 6-mm-long implants lost an average of 1.34 ± 0.35 mm of peri-implant bone at 5 years versus 2.11 ± 0.59 mm in patients with implants at least 10-mm long. The difference was statistically significant (mean difference = 0.77 ± 0.70 mm; 95% CI: 0.32 to 1.21 mm; P = 0.003). In maxillae, patients with 6-mm-long implants lost an average of 1.52 ± 0.47 mm of peri-implant bone at 5 years versus 1.85 ± 0.51 mm in patients with implants at least 10-mm long. The difference was statistically significant (mean difference = 0.33 ± 0.36 mm; 95% CI: 0.14 to 0.53 mm; P = 0.002).Results at 5 years after loading indicate that 6-mm-long implants with a conventional diameter of 4 mm achieved similar results to longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation, especially in posterior mandibles since the treatment was faster, cheaper and associated with less morbidity. However, 10-year post-loading data are necessary before making reliable recommendations.
  •  
7.
  •  
8.
  • Giudice, Amerigo, et al. (author)
  • Dental extractions for patients on oral antiplatelet: a within-person randomised controlled trial comparing haemostatic plugs, advanced-platelet-rich fibrin (A-PRF+) plugs, leukocyte- and platelet-rich fibrin (L-PRF) plugs and suturing alone.
  • 2019
  • In: International journal of oral implantology (New Malden, London, England). - 2631-6439. ; 12:1, s. 77-87
  • Journal article (peer-reviewed)abstract
    • To compare the outcome of tooth extractions in patients taking oral antithrombotic without reducing their dose. Four different interventions were compared within the same patient: suturing alone (control group), suturing plus a haemostatic plug, suturing plus advanced-platelet-rich fibrin (A-PRF+) plug, and suturing plus leukocyte- and platelet-rich fibrin (L-PRF) plug into the socket.Forty patients, taking oral antiplatelet agents, requiring the extraction of at least four non-adjacent teeth were selected for the study. After extractions the sockets were randomly allocated to suturing alone (control group), suturing plus haemostatic plug (HAEM), suturing plus advanced-platelet-rich fibrin (A-PRF+) plug, and suturing plus leukocyte- and platelet-rich fibrin (L-PRF) plug into the socket without reducing the dose of oral antiplatelets according to a split-mouth design. Outcome measures were complications, time to complete each procedure, postoperative bleeding, costs of the materials, patient preference and a wound healing index recorded 1 and 2 weeks postextraction by blinded assessors.Two weeks after extraction no patient dropped out and no complication was reported. The average time to complete suturing after tooth extractions was: 1.0 ± 0.00 minutes at control sites, 1.5 ± 0.41 at HAEM sites, 2.8 ± 0.61 at A-PRF+ sites, and 2.8 ± 0.56 at L-PRF sites, the difference being statistically significant between each pairwise comparison except A-PRF+ vs L-PRF. Postoperative bleeding 30 minutes after extractions was present at 8, 5, 1 and 2 sites for control, HAEM, A-PRF+ and L-PRF sites, respectively. A-PRF showed statistically significantly less bleeding compared to the control group (odds ratio = 0.1 (95% CI [0.01;0.86]; P < 0.0361). In all cases bleeding was moderate in nature and not severe. One week after extractions the mean wound healing index was 1.05 ± 0.60 for control, 1.18 ± 0.59 for HAEM, 1.00 ± 0.68 for A-PRF+ and 0.95 ± 0.50 for L-PRF sites. No statistically significant difference was detected across groups (P = 0.633). Two weeks after extractions the mean wound healing index was 0.33 ± 0.53 for control, 0.43 ± 0.50 for HAEM, 0.25 ± 0.49 for A-PRF+ and 0.15 ± 0.36 for L-PRF sites. No statistically significant difference across groups was detected (P = 0.255). One week after extractions, nine patients preferred control sites, eight HAEM, ten A-PRF+, four L-PRF and nine had no preference. No statistically significant differences were detected for control sites (P = 0.6779), HAEM (P = 1.0000), A-PRF+ (P = 0.4055) and L-PRF (P = 0.1472). Two weeks after extractions five patients preferred control sites, three HAEM, eight A-PRF+, eight L-PRF and 16 had no preference. No statistically significant differences were detected for control sites (P = 0.8147), HAEM (P = 0.2363), A-PRF+ (P = 0.3488) and L-PRF (P = 0.3488). Costs without counting sutures and blood centrifuges were 0.00, 14.49, 2.44 and 2.44 Euro for control, HAEM, A-PRF+ and L-PRF sites, respectively.It may not be necessary to discontinue the use of oral antiplatelets in patients undergoing dental extractions and, when present, the minor statistically significant differences between procedures were not clinically relevant; therefore clinicians can use any of the tested interventions according to their preference, keeping in mind that simple suturing is sufficient and is faster and cheaper, and that A-PRF+ was associated with less postoperative bleeding when compared to suturing alone.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view