SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "L773:9781509014163 "

Search: L773:9781509014163

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Tas, E., et al. (author)
  • Proficiency testing for conducted immunity with a new round robin test device
  • 2016
  • In: 2016 International Symposium on Electromagnetic Compatibility - EMC EUROPE. - 9781509014163 ; , s. 274-279
  • Conference paper (peer-reviewed)abstract
    • Last year, a new round robin test device was proposed for inter-laboratory comparisons in conducted immunity testing according to IEC 61000-4-6[1]. The device has recently been successfully evaluated among all EMRP Project partners. The device is able to confirm or to deny the testing capability of a laboratory by recording a full set of parameters. The device is now ready for deployment as the first commercial proficiency testing device for conducted immunity.
  •  
2.
  • Ängskog, Per, et al. (author)
  • Shielding Effectiveness of Energy Saving Windows and HPM Effects on Coated Window Panes Measurements Conducted 2014-2016-Results and Lessons Learned
  • 2016
  • In: PROCEEDINGS OF THE 2016 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE. - : IEEE conference proceedings. - 9781509014163 ; , s. 461-466, s. 461-466
  • Conference paper (peer-reviewed)abstract
    • The past few decades have shown a veritable explosion of new versions of energy-saving windows and coated window panes. In the wake of this, problems with radio communications into and from within buildings has arisen. However, this unexpected attenuation of radio signals may also be used to shield a facility from incoming intentional electromagnetic interference (IEMI). With the intention to investigate the shielding effectiveness (SE) of modern windows and window panes a two-year measurement campaign was launched mid-2014. Another, little investigated area is what happens to coated glass when irradiated by a high-power microwave (HPM) source. Shielding effectiveness has been measured for different types of energy saving windows and coated window panes both in a semi-anechoic chamber and in a reverberation chamber over the frequency range 1-18 GHz. The effects of HPM irradiation were studied by comparing SE measured before and after the pulsed 28 kV/m L-band irradiation. The main conclusion is that with the right choice of window the shielding effectiveness of a building can reach up 40-50 dB. In this paper we summarize these measurements and lessons learned from the measurement campaign.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view