SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Alsholm Peter) "

Search: WFRF:(Alsholm Peter)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Nilsson, Annika M. K., et al. (author)
  • T-matrix computations of light scattering by red blood cells
  • 1998
  • Reports (other academic/artistic)abstract
    • The electromagnetic far field, as well as near field, originating from light interaction with a red blood cell (RBC) volume equivalent spheroid, were analyzed utilizing T-matrix theory. This method is a powerful tool which enables the influence of cell shape on the angular distribution of scattered light to be studied. General observations were that the three-dimensional shape, as well as optical thickness apparent to the incident field, affect the forward scattering. The back scattering was influenced by the shape of the surface facing the incident beam. Furthermore, sphering as well as elongation of an oblate shaped RBC into a volume equivalent sphere or prolate shaped spheroid, respectively, were theoretically modeled in order to imitate physiological phenomena caused, e.g., by sphering agents, heat or increased shear stress of flowing blood. Both sphering and elongation were shown to decrease the intensity of the forward directed scattering, thus yielding lower g-factors. The sphering made the scattering pattern independent of the azimuthal scattering angle φs, while the elongation induced more apparent φs-dependent patterns. The light scattering by an RBC volume equivalent spheroid, was thus found to be highly influenced by the shape of the scattering object. A near-field radius, rnf, was evaluated as the distance to which the maximum intensity of the total near field had decreased to 2.5 times that of the incident field. It was estimated to 2-24.5 times the maximum radius of the scattering spheroid, corresponding to 12-69 µm. When the absorption properties of a red blood cell were incorporated in the computations, the near-field radius was only slightly reduced by 0.2-0.6 times the maximum radius. As the near-field radius was shown to be larger than a simple estimation of the distance between the RBCs in whole blood, the assumption of independent scattering, frequently employed in optical measurements on whole blood, seems inappropriate. This also indicates that results obtained from diluted blood, cannot be extrapolated to whole blood, by multiplying with a simple concentration factor.
  •  
2.
  • Nilsson, Annika M. K., et al. (author)
  • T-matrix computations of light scattering by red blood cells
  • 1998
  • In: Applied Optics. - 1559-128X. ; 37:13, s. 2735-2748
  • Journal article (peer-reviewed)abstract
    • The electromagnetic far field, as well as the near field, originating from light interaction with a red blood cell ~RBC! volume-equivalent spheroid, was analyzed by utilizing the T-matrix theory. This method is a powerful tool that makes it possible to study the influence of cell shape on the angular distribution ofscattered light. General observations were that the three-dimensional shape, as well as the optical thickness apparent to the incident field, affects the forward scattering. The backscattering was influenced by the shape of the surface facing the incident beam. Furthermore sphering as well as elongation of an oblate RBC into a volume-equivalent sphere or a prolate spheroid, respectively, was theoretically modeled to imitate physiological phenomena caused, e.g., by heat or the increased shear stress of flowing blood. Both sphering and elongation were shown to decrease the intensity of the forward-directed scattering, thus yielding lower g factors. The sphering made the scattering pattern independent ofazimuthal scattering angle fs, whereas the elongation induced more apparent fs-dependent patterns. The light scattering by a RBC volume-equivalent spheroid was thus found to be highly influenced by the shape of the scattering object. A near-field radius rnf was evaluated as the distance to which the maximum intensity of the total near field had decreased to 2.5 times that of the incident field. It was estimated to 2–24.5 times the maximum radius of the scattering spheroid, corresponding to 12–69 mm. Because the near-field radius was shown to be larger than a simple estimation of the distance between the RBC’s in whole blood, the assumption of independent scattering, frequently employed in opticalmeasurements on whole blood, seems inappropriate. This also indicates that one cannot extrapolate the results obtained from diluted blood to whole blood by multiplying with a simple concentration factor.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
reports (1)
journal article (1)
Type of content
other academic/artistic (1)
peer-reviewed (1)
Author/Editor
Karlsson, Anders (2)
Andersson-Engels, St ... (2)
Nilsson, Annika M. K ... (2)
Alsholm, Peter (2)
University
Lund University (2)
Language
English (2)
Research subject (UKÄ/SCB)
Natural sciences (1)
Engineering and Technology (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view