1.
  • Grubb, Anders, et al. (author)
  • First certified reference material for cystatin C in human serum ERM-DA471/IFCC.
  • 2010
  • In: Clinical Chemistry and Laboratory Medicine. - 1434-6621. ; 48:11, s. 1619-1621
  • Journal article (peer-reviewed)abstract
    • The IFCC Working Group for the Standardisation of Cystatin C (WG-SCC), in collaboration with the Institute for Reference Materials and Measurements (IRMM), announces the availability of the new certified reference material ERM-DA471/IFCC. The material was characterised using a pure protein primary reference preparation (PRP) as calibrant. The PRP was prepared from recombinant cystatin C, and its concentration measured using dry mass determination. The characterisation of ERM-DA471/IFCC was performed by particle enhanced immuno-nephelometry, particle enhanced immuno-turbidimetry, and enzyme amplified single radial immuno-diffusion. The certified cystatin C mass concentration in ERM-DA471/IFCC, if reconstituted according to the specified procedure, is 5.48 mg/L, the expanded uncertainty (k=2) being 0.15 mg/L.
  •  
2.
  • Grubb, Anders, et al. (author)
  • Generation of a new cystatin C-based estimating equation for glomerular filtration rate by use of 7 assays standardized to the international calibrator
  • 2014
  • In: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 60:7, s. 974-986
  • Journal article (peer-reviewed)abstract
    • BACKGROUND:Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays.METHODS:Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations. By use of 2 of these assays and a population of 4690 subjects, with large subpopulations of children and Asian and Caucasian adults, with their GFR determined by either renal or plasma inulin clearance or plasma iohexol clearance, we attempted to produce a virtually assay-independent simple cystatin C-based equation for estimation of GFR.RESULTS:We developed a simple cystatin C-based equation for estimation of GFR comprising only 2 variables, cystatin C concentration and age. No terms for race and sex are required for optimal diagnostic performance. The equation, [Formula: see text] is also biologically oriented, with 1 term for the theoretical renal clearance of small molecules and 1 constant for extrarenal clearance of cystatin C.CONCLUSIONS:A virtually assay-independent simple cystatin C-based and biologically oriented equation for estimation of GFR, without terms for sex and race, was produced.
  •  