  • Eriksson, L, et al. (author)
  • An investigation of sensitivity limits in PET scanners
  • 2007
  • In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : Elsevier BV. - 0168-9002. ; 580:2, s. 836-842
  • Journal article (other academic/artistic)
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Eriksson, Lars, et al. (author)
  • Towards Sub-Minute PET Examination Times
  • 2011
  • In: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 58:1, s. 76-81
  • Journal article (peer-reviewed)abstract
    • The main performance parameters in positron camera system design are sensitivity and spatial resolution. This paper concerns sensitivity, which is a function of the scintillation material, the solid angle subtended by the detector array, and the scintillator packing fraction. The solid angle can be increased by extending the axial extent of cylindrical detector systems. Most commercial positron camera systems are based on rings of detector blocks with lutetium oxyorthosilicate, LSO:Ce or LYSO:Ce, as the scintillator of choice. By adding more rings, the solid angle and thus the absolute sensitivity increases while the singles detection efficiency remains fairly constant assuming the same crystal thickness. It has been shown that Ca co-doping of LSO:Ce reduces the scintillation decay time to similar to 30 ns with a light output over 30000 ph/MeV. This improvement may give a time-of-flight (TOF) advantage with time resolution of 500 ps or less. If the count rate sensitivity of a large axial field-of-view (AFOV) system is combined with the TOF sensitivity increase, we have the means to create examination times in the sub-minute range with no compromise in image quality. In the present study we have compared the existing Siemens molecular CT (mCT) systems to future 6, 8, 12, 20 and higher block ring systems with and without TOF. The mCT 4 block ring system has been used as a reference. The time for acceptable image quality with this system is then extrapolated to other systems based on planar sensitivity. However, the planar sensitivity is related to the solid angle, and reaches saturation for large AFOVs. This implies that there is an upper count rate sensitivity limit. A 20 block ring system may cover a 70 cm examination range at a certain planar count rate and could provide acceptable quality images in approximately 10 seconds by combining the high planar sensitivity count rate provided by the multi-ring feature, the high stopping power of LSO and the TOF gain due to the improved timing resolution. The increased sensitivity may be used to reduce patient dose.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-7 of 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view