SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Betti A.) "

Search: WFRF:(Betti A.)

  • Result 1-10 of 16
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Apponi, A., et al. (author)
  • Heisenberg's uncertainty principle in the PTOLEMY project : A theory update
  • 2022
  • In: Physical Review D. - : American Physical Society. - 2470-0010 .- 2470-0029. ; 106:5
  • Journal article (peer-reviewed)abstract
    • We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the beta-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised by Cheipesh, Cheianov, and Boyarsky [Phys. Rev. D 104, 116004 (2021)], and discuss the relevant timescales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.
  •  
3.
  • Apponi, A., et al. (author)
  • Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter
  • 2022
  • In: Journal of Instrumentation. - : IOP Publishing Ltd. - 1748-0221. ; 17:5
  • Journal article (peer-reviewed)abstract
    • The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.
  •  
4.
  • Betti, M. G., et al. (author)
  • Neutrino physics with the PTOLEMY project : active neutrino properties and the light sterile case
  • 2019
  • In: Journal of Cosmology and Astroparticle Physics. - : IOP PUBLISHING LTD. - 1475-7516. ; :7
  • Journal article (peer-reviewed)abstract
    • The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino Background (CNB) detector, the first of its kind and the only one conceived that can look directly at the image of the Universe encoded in neutrino background produced in the first second after the Big Bang. The scope of the work for the next three years is to complete the conceptual design of this detector and to validate with direct measurements that the non-neutrino backgrounds are below the expected cosmological signal. In this paper we discuss in details the theoretical aspects of the experiment and its physics goals. In particular, we mainly address three issues. First we discuss the sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the perspectives of the experiment to detect the CNB via neutrino capture on tritium as a function of the neutrino mass scale and the energy resolution of the apparatus. Finally, we consider an extra sterile neutrino with mass in the eV range, coupled to the active states via oscillations, which has been advocated in view of neutrino oscillation anomalies. This extra state would contribute to the tritium decay spectrum, and its properties, mass and mixing angle, could be studied by analyzing the features in the beta decay electron spectrum.
  •  
5.
  • Jones, Gregory T., et al. (author)
  • Meta-Analysis of Genome-Wide Association Studies for Abdominal Aortic Aneurysm Identifies Four New Disease-Specific Risk Loci
  • 2017
  • In: Circulation Research. - 0009-7330 .- 1524-4571. ; 120:2, s. 341-
  • Journal article (peer-reviewed)abstract
    • Rationale: Abdominal aortic aneurysm (AAA) is a complex disease with both genetic and environmental risk factors. Together, 6 previously identified risk loci only explain a small proportion of the heritability of AAA. Objective: To identify additional AAA risk loci using data from all available genome-wide association studies. Methods and Results: Through a meta-analysis of 6 genome-wide association study data sets and a validation study totaling 10 204 cases and 107 766 controls, we identified 4 new AAA risk loci: 1q32.3 (SMYD2), 13q12.11 (LINC00540), 20q13.12 (near PCIF1/MMP9/ZNF335), and 21q22.2 (ERG). In various database searches, we observed no new associations between the lead AAA single nucleotide polymorphisms and coronary artery disease, blood pressure, lipids, or diabetes mellitus. Network analyses identified ERG, IL6R, and LDLR as modifiers of MMP9, with a direct interaction between ERG and MMP9. Conclusions: The 4 new risk loci for AAA seem to be specific for AAA compared with other cardiovascular diseases and related traits suggesting that traditional cardiovascular risk factor management may only have limited value in preventing the progression of aneurysmal disease.
  •  
6.
  • Betti, M. G., et al. (author)
  • A design for an electromagnetic filter for precision energy measurements at the tritium endpoint
  • 2019
  • In: Progress in Particle and Nuclear Physics. - : Elsevier BV. - 0146-6410 .- 1873-2224. ; 106, s. 120-131
  • Research review (peer-reviewed)abstract
    • We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of E x B is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential along the mid-plane of the filter. As a function of drift distance along the length of the filter, the filter zooms in with exponentially increasing precision on the transverse velocity component of the electron kinetic energy. This yields a linear dimension for the total filter length that is exceptionally compact compared to previous techniques for electromagnetic filtering. The parallel velocity component of the electron kinetic energy oscillates in an electrostatic harmonic trap as the electron drifts along the length of the filter. An analysis of the phase-space volume conservation validates the expected behavior of the filter from the adiabatic invariance of the orbital magnetic moment and energy conservation following Liouville's theorem for Hamiltonian systems.
  •  
7.
  • Outola, I., et al. (author)
  • Characterization of the NIST Seaweed Standard Reference Material
  • 2006
  • In: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 64:10-11, s. 1242-1247
  • Journal article (peer-reviewed)abstract
    • The National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) for seaweed was developed through an interlaboratory comparison with 24 participants from 16 countries. After evaluating different techniques to calculate certified values for the radionuclides, the median method was found to be the most representative technique. The certified values were provided for 13 radionuclides and information values were given for 15 more radionuclides. Results for the natural decay series showed disequilibrium in both the uranium and thorium series. (c) 2006 Elsevier Ltd. All rights reserved.
  •  
8.
  • De Stefano, V., et al. (author)
  • High rate of recurrent venous thromboembolism in patients with myeloproliferative neoplasms and effect of prophylaxis with Vitamin K antagonists
  • 2016
  • In: Leukemia. - : Springer Science and Business Media LLC. - 0887-6924 .- 1476-5551. ; 30:10, s. 2032-2038
  • Journal article (peer-reviewed)abstract
    • The optimal duration of treatment with vitamin K antagonists (VKA) after venous thromboembolism (VTE) in patients with Philadelphia-negative myeloproliferative neoplasms (MPNs) is uncertain. To tackle this issue, we retrospectively studied 206 patients with MPN-related VTE (deep venous thrombosis of the legs and/or pulmonary embolism). After this index event, we recorded over 695 pt-years 45 recurrences, venous in 36 cases, with an incidence rate (IR) of 6.5 per 100 pt-years (95% confidence interval (CI): 4.9-8.6). One hundred fifty-five patients received VKA; the IR of recurrent thrombosis per 100 pt-years was 4.7 (95% CI: 2.8-7.3) on VKA and 8.9 (95% CI: 5.7-13.2) off VKA (P=0.03). In patients receiving VKA, the IR of recurrent thrombosis per 100 pt-years was 5.3 (95% CI: 3.2-8.4) among 108 patients on long-term VKA and 12.8 (95% CI: 7.3-20.7) after discontinuation among the 47 who ceased treatment (P=0.008), with a doubled risk of recurrence after stopping VKA (hazard ratio: 2.21, 95% CI: 1.19-5.30). The IR of major bleeding per 100 pt-years was 2.4 (95%: CI: 1.1-4.5) on VKA and 0.7 (95% CI: 0.08-2.5) off VKA (P=0.08). In conclusion, in MPN patients with VTE recurrent thrombosis is significantly reduced by VKA and caution should be adopted in discontinuation; however, the incidence of recurrence on treatment remains high, calling for clinical trials aimed to improve prophylaxis in this setting.
  •  
9.
  • De Stefano, V., et al. (author)
  • Splanchnic vein thrombosis in myeloproliferative neoplasms : Risk factors for recurrences in a cohort of 181 patients
  • 2016
  • In: Blood Cancer Journal. - : Springer Science and Business Media LLC. - 2044-5385. ; 6:11
  • Journal article (peer-reviewed)abstract
    • We retrospectively studied 181 patients with polycythaemia vera (n=67), essential thrombocythaemia (n=67) or primary myelofibrosis (n=47), who presented a first episode of splanchnic vein thrombosis (SVT). Budd-Chiari syndrome (BCS) and portal vein thrombosis were diagnosed in 31 (17.1%) and 109 (60.3%) patients, respectively; isolated thrombosis of the mesenteric or splenic veins was detected in 18 and 23 cases, respectively. After this index event, the patients were followed for 735 patient years (pt-years) and experienced 31 recurrences corresponding to an incidence rate of 4.2 per 100 pt-years. Factors associated with a significantly higher risk of recurrence were BCS (hazard ratio (HR): 3.03), history of previous thrombosis (HR: 3.62), splenomegaly (HR: 2.66) and leukocytosis (HR: 2.8). Vitamin K-antagonists (VKA) were prescribed in 85% of patients and the recurrence rate was 3.9 per 100 pt-years, whereas in the small fraction (15%) not receiving VKA more recurrences (7.2 per 100 pt-years) were reported. Intracranial and extracranial major bleeding was recorded mainly in patients on VKA and the corresponding rate was 2.0 per 100 pt-years. In conclusion, despite anticoagulation treatment, the recurrence rate after SVT in myeloproliferative neoplasms is high and suggests the exploration of new avenues of secondary prophylaxis with new antithrombotic drugs and JAK-2 inhibitors.
  •  
10.
  • Farnocchia, Davide, et al. (author)
  • The Second International Asteroid Warning Network Timing Campaign: 2005 LW3
  • 2023
  • In: The Planetary Science Journal. - : Institute of Physics (IOP). - 2632-3338. ; 4:11
  • Journal article (peer-reviewed)abstract
    • The Earth close approach of near-Earth asteroid 2005 LW3 on 2022 November 23 represented a good opportunity for a second observing campaign to test the timing accuracy of astrometric observation. With 82 participating stations, the International Asteroid Warning Network collected 1046 observations of 2005 LW3 around the time of the close approach. Compared to the previous timing campaign targeting 2019 XS, some individual observers were able to significantly improve the accuracy of their reported observation times. In particular, U.S. surveys achieved good timing performance. However, no broad, systematic improvement was achieved compared to the previous campaign, with an overall negative bias persisting among the different observers. The calibration of observing times and the mitigation of timing errors should be important future considerations for observers and orbit computers, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view