1.
  • Malengo, A., et al. (author)
  • Final report on EURAMET project 1395/EURAMET.M.FF-K4.1.2016 : Volume comparison at 20 L
  • 2020
  • In: Metrologia. - : Institute of Physics Publishing. - 0026-1394 .- 1681-7575. ; 57:1
  • Journal article (peer-reviewed)abstract
    • During the EURAMET TC-F annual meeting, held in Boras in 2015, it was agreed to perform the follow up of the CCM.FF-K4.1.2011 organized for the EURAMET NMIs for volume of liquids at 20 L. The transfer standard was a 20 L pipette supplied by CENAM. The participants of this comparison also involved in the comparison CCM.FF-K4.1.2011 were: CENAM, INRIM, IPQ, RISE and VSL, in total there were twenty-one participants. The comparison was organized in two petals, INIRM perform three measurements, at the beginning, after the first petal and at the end of the circulation. The comparison measurements started in April 2016 and ended in October 2017. It should be noted that most of the participants (thirteen) declared an expanded uncertainty less than 0,005 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). 
  •  
2.
  • Altlntaş, A., et al. (author)
  • Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure
  • 2020
  • In: Metrologia. - : Institute of Physics Publishing. - 0026-1394 .- 1681-7575. ; 57:1
  • Journal article (peer-reviewed)abstract
    • A EURAMET key comparison of the national pressure standards in the range 0.7 MPa to 7.0 MPa of gas gauge pressure was carried out. The circulation of the transfer standard began in November 2011 and lasted until November 2016. The measurand of the comparison was the effective area of the piston-cylinder assembly determined by gauge pressure measurements in the range from 0.7 MPa to 7.0 MPa. As the comparison reference value, the weighted mean of the results of the laboratories with primary pressure standards was used. With this reference value, all the participants who delivered the results demonstrated equivalence respective to the reference value within expanded uncertainties (k = 2) on all the range. The results of this comparison were linked to CCM key comparison CCM.P-K1.c. Also in relation to the reference values of CCM.P-K1.c, all participants demonstrated agreement within expanded uncertainties (k = 2) at all pressure points.
  •  