1.
  • Brasil, DM, et al. (author)
  • Image quality optimization of narrow detector dental computed tomography for paediatric patients
  • 2019
  • In: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 48:5, s. 20190032-
  • Journal article (peer-reviewed)abstract
    • Dental CBCT exposure parameters should be optimized according to patient-specific indications, mainly for children that are most vulnerable to harmful effects of ionizing radiation. The aim of this study was to determine optimized kV settings for paediatric acquisitions for a dental CBCT device. Methods: Clinical and quantitative evaluations of image quality were performed using 5 and 10 years old (y/o) anthropomorphic phantoms. Technical evaluation was performed with the SEDENTEXCT-IQ phantom. Images were obtained using a PaX-i3D Green CBCT (Vatech, Korea) device, combining tube voltages ranging from 85 to 110 kV and 2 fields of view (FOVs: 21 × 19 and 12 × 9 cm), while maintaining the radiation dose fixed by adjusting the mA accordingly. Clinically, observers assessed images based on overall quality, sharpness, contrast, artefacts, and noise. For quantitative evaluation, mean grey value shift, % increase standard deviation, % beam-hardening and contrast-to-noise ratio were calculated. For technical evaluation, segmentation accuracy, contrast-to-noise ratio and full width at half maximum were measured. Biplot graphs were used to choose representative parameters, from which the best kV was selected for each protocol and evaluation. kV values that had no statistical differences (p > 0.05) with the best kV chosen were considered as having the same quality. Results: Clinically, 95 kV was found as a cut-off value. From the quantitative aspect, 85 kV (p < 0.05) showed the worst quality, except in 12 × 9 cm 5 y/o. Technically, 85 and 110 kV in the large FOV showed significantly worse quality for the large FOV. Conclusion: For paediatric indications, 95 kV or higher (and correspondingly low mA values) was found as optimal.
  •  
2.
  •  
3.
  •  
4.
  • Brasil, DM, et al. (author)
  • Monitoring cone-beam CT radiation dose levels in a University Hospital
  • 2023
  • In: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 52:3, s. 20220213-
  • Journal article (peer-reviewed)abstract
    • To present patient dose levels for different CBCT scanners, acquired by a dose monitoring tool in a University Hospital, as a function of field of view (FOV), operation mode, and patient age. Methods: An integrated dose monitoring tool was used to collect radiation exposure data [type of CBCT unit, dose-area product (DAP), FOV size, and operation mode] and patient demographic information (age, referral department) performed on a 3D Accuitomo 170 and a Newtom VGI EVO unit. Effective dose conversion factors were calculated and implemented into the dose monitoring system. For each CBCT unit, the frequency of examinations, clinical indications, and effective dose levels were obtained for different age and FOV groups, and operation modes. Results: A total of 5163 CBCT examinations were analyzed. Surgical planning and follow-up were the most frequent clinical indications. For the standard operation mode, effective doses ranged from 35.1 to 300 µSv and 9.26-117 µSv using 3D Accuitomo 170 and Newtom VGI EVO, respectively. In general, effective doses decreased with increasing age and FOV size reduction. Conclusions: Effective dose levels varied notably between systems and operation modes.Operation mode selection and FOV size were indication-oriented, with larger FOV sizes election serving surgical planning and follow-up. Seeing the influence of FOV size on effective dose levels, manufacturers could be advised to move toward patient-specific collimation and dynamic FOV selection. Systematically monitoring patient doses could be recommended for steering future CBCT optimization.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • 2017
  • swepub:Mat__t
  •  