SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Buraczewska Iwona) "

Sökning: WFRF:(Buraczewska Iwona)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ainsbury, Elizabeth, et al. (författare)
  • Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans - joint RENEB and EURADOS inter-laboratory comparisons
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 99-109
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. Materials and methods: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation induced thermoluminescent signals in glass screens taken from mobile phones. Results: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. Conclusions: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.
  •  
2.
  • Brzozowska, Beata, et al. (författare)
  • RENEB accident simulation exercise
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 75-80
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. Materials and methods: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. Results: The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). Conclusions: Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.
  •  
3.
  • Czub, Joanna, et al. (författare)
  • Biological effects of mixed-ion beams. Part 1 : Effect of irradiation of the CHO-K1 cells with a mixed-ion beam containing the carbon and oxygen ions
  • 2018
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 139, s. 304-309
  • Tidskriftsartikel (refereegranskat)abstract
    • Carbon and oxygen ions were accelerated simultaneously to estimate the effect of irradiation of living cells with the two different ions. This mixed ion beam was used to irradiate the CHO-K1 cells, and a survival test was performed. The type of the effect of the mixed ion beam on the cells was determined with the isobologram method, whereby survival curves for irradiations with individual ion beams were also used. An additive effect of irradiation with the two ions was found.
  •  
4.
  • Czub, Joanna, et al. (författare)
  • Biological effects of mixed-ion beams. Part 2 : The relative biological effectiveness of CHO-K1 cells irradiated by mixed- and single-ion beams
  • 2019
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 150, s. 192-198
  • Tidskriftsartikel (refereegranskat)abstract
    • The relative biological effectiveness (RBE) values were determined for single- and mixed-ion beams containing carbon and oxygen ions. The CHO-K1 cells were irradiated with beams with the linear energy transfer (LET) values of 236-300 and 461-470 keV/mu m for C-12 and O-16 ions, respectively. The RBE was estimated as a function of dose, survival fraction (SF) and LET. The SF was not affected by varying contributions of the constituent ions to the total mixed dose. The RBE has the same value for single-ion exposures with ions with LET 300 (C-12) and 470 keV/mu m (O-16).
  •  
5.
  • Depuydt, Julie, et al. (författare)
  • RENEB intercomparison exercises analyzing micronuclei (Cytokinesis-block Micronucleus Assay)
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 36-47
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one. Materials and methods: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate. Micronucleus analysis was performed by automated, semi-automated and manual procedures. Results: The dose estimates provided by network laboratories were in good agreement with true administered doses. The most accurate estimates were reported for low dose points (<= 0.94 Gy). For higher dose points (>= 2.7 Gy) a larger variation in estimates was observed, though in the second exercise the number of acceptable estimates increased satisfactorily. Higher accuracy was achieved with the semi-automated method. Conclusion: The results of the two exercises performed by our network demonstrate that the micronucleus assay is a useful tool for large-scale radiation emergencies, and can be successfully implemented within a large network of laboratories.
  •  
6.
  • Francesc Barquinero, Joan, et al. (författare)
  • RENEB biodosimetry intercomparison analyzing translocations by FISH
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 30-35
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. Materials and methods: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. Results: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. Conclusions: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.
  •  
7.
  • Johannes, Christian, et al. (författare)
  • The yield of radiation-induced micronuclei in early and late-arising binucleated cells depends on radiation quality.
  • 2010
  • Ingår i: Mutation research. - : Elsevier BV. - 0027-5107 .- 1873-135X. ; 701:1, s. 80-5
  • Tidskriftsartikel (refereegranskat)abstract
    • There are conflicting data regarding the effect of culturing time of human peripheral blood lymphocytes on the yield of chromosomal aberrations induced by sparsely ionising radiation in the G0 phase of the cell cycle. While some authors find that the yield of aberrations does not change with time, others find increased frequencies of aberrations with harvesting time. The reasons for the conflicting results are not known, but the majority of studies were performed with lymphocytes of a single donor collected at one time point. We performed a study to verify if individual variability could be a confounding factor. As a positive control, lymphocytes were also exposed to high LET radiation (neutrons and alpha-rays), where an effect of harvesting time on the level of damage is expected to be seen. Blood was drawn from a total of 8 donors at two time points and exposed to X-rays, 6 MeV neutrons or alpha particles generated by an Am-241 source. Whole blood cultures were set up and micronuclei (Mn) were scored in binucleated cells harvested after 72, 96 and 120 h of culture time. The results show that in lymphocytes exposed to X-rays, the frequency of Mn was generally not influenced by the culture time while for both neutrons and alpha particles consistently increased micronucleus frequencies with culture time were detected. Some individual variability was detected and the conflicting results regarding the relationship between the yield of cytogenetic damage and lymphocyte culture time can, at least partly, be due to this variability.
  •  
8.
  • Terzoudi, Georgia I., et al. (författare)
  • Dose assessment intercomparisons within the RENEB network using G(0)-lymphocyte prematurely condensed chromosomes (PCC assay)
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 48-57
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G(0)-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay. Materials and methods: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy gamma-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals. Results: Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics. Conclusions: Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G(0)-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy