1.
  • Boudreau, Mathieu, et al. (författare)
  • Repeat it without me: Crowdsourcing the T1 mapping common ground via the ISMRM reproducibility challenge
  • 2024
  • Ingår i: MAGNETIC RESONANCE IN MEDICINE. - 0740-3194 .- 1522-2594. ; 92:3, s. 1115-1127
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose T-1 mapping is a widely used quantitative MRI technique, but its tissue-specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well-established inversion-recovery T-1 mapping technique, using acquisition details from a seminal T-1 mapping paper on a standardized phantom and in human brains. Methods The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T-1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open-source platforms. Intersubmission and intrasubmission comparisons were performed. Results Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also eveloped: https://rrsg2020.dashboards.neurolibre.org. Conclusion The T-1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T-1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T-1 variations in vivo.
  •  
2.
  • Chougar, Lydia, et al. (författare)
  • Signal Intensity within Cerebral Venous Sinuses on Synthetic MRI
  • 2020
  • Ingår i: MAGNETIC RESONANCE IN MEDICAL SCIENCES. - : JPN SOC MAGNETIC RESONANCE MEDICINE. - 1347-3182 .- 1880-2206. ; 19:1, s. 56-63
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Flowing blood sometimes appears bright on synthetic T-1-weighted images, which could be misdiagnosed as a thrombus. This study aimed to investigate the frequency of hyperintensity within cerebral venous sinuses on synthetic MR images and to evaluate the influence of increasing flow rates on signal intensity using a flow phantom. Materials and Methods: Imaging data, including synthetic and conventional MRI scans, from 22 patients were retrospectively analyzed. Signal intensities at eight locations of cerebral venous sinuses on synthetic images were graded using the following three-point scale: 0, "dark vessel"; 1, "hyperintensity within the walls"; and 2, "hyperintensity within the lumen:" A phantom with gadolinium solution inside a U-shaped tube was acquired without flow and then with increasing flow rates (60, 100, 200, 300, 400 ml/min). Results: Considering all sinus locations, the venous signal intensity on synthetic T-1-weighted images was graded as 2 in 79.8% of the patients. On synthetic T-2-weighted images, all sinuses were graded as 0. On fluid-attenuated inversion recovery (FLAIR) images, sinuses were almost always graded as 0 (99.4%). In the phantom study, the signal initially became brighter on synthetic T-1-weighted images as the flow rate increased. Above a certain flow rate, the signal started to decrease. Conclusion: High signal intensity within the cerebral venous sinuses is a frequent finding on synthetic T-1-weighted images. This corresponds to the hyperintensity noted at certain flow rates in the phantom experiment.
  •  