SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Cutkosky Mark) "

Search: WFRF:(Cutkosky Mark)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Edin, Benoni B, et al. (author)
  • A Physiological Method for Relaying Frictional Information to a Human Teleoperator
  • 1993
  • In: IEEE Transactions on Systems, Man and Cybernetics. - 0018-9472 .- 2168-2909. ; 23:2, s. 427-432
  • Journal article (peer-reviewed)abstract
    • The ability to sense and respond to frictional variations is important for dexterous manipulation. It has been demonstrated that humans apply forces to an object on the basis of its anticipated frictional properties. After contact , tactile receptors provide information on the actual frictional properties and ensure that the applied finger tip allow for a safety margin against slips during the ensuing manipulation. With inappropriate forces, incipient and overt slips occur which produce receptor discharges and elicit automatic adjustments of the finger tip forces to increase the safety margins against future slips. It is demonstrated that it is possible to elicit rapid, nonhabituating and sustained grasp responses by means of a tactile display. Subjects grasped and lifted an instrumented test object using the thumb and index finger. While the object was held in air, rapid but small sliding movements were invoked between the object and either contact plate and caused a load force redistribution. This reliably triggered a grasp force increase similar to the ones elicited by natural slips occuring during normal manipulation. An important application of this finding is in relaying frictional information from a slave hand to a human operator. Furthermore, it may make it possible to reduce disparity between master and slave hands in force reflective telemanipulation systems.
  •  
2.
  • Kight, Ali, et al. (author)
  • Decoupling Transmission and Transduction for Improved Durability of Highly Stretchable, Soft Strain Sensing : Applications in Human Health Monitoring
  • 2023
  • In: Sensors. - : MDPI AG. - 1424-8220. ; 23:4
  • Journal article (peer-reviewed)abstract
    • This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.
  •  
3.
  • Pirozzi, Ileana, et al. (author)
  • Circulatory Support : Artificial Muscles for the Future of Cardiovascular Assist Devices
  • 2023
  • In: Advanced Materials. - : Wiley. - 0935-9648 .- 1521-4095.
  • Journal article (peer-reviewed)abstract
    • Artificial muscles enable the design of soft implantable devices which are poised to transform the way we mechanically support the heart today. Heart failure is a prevalent and deadly disease, which is treated with the implantation of rotary blood pumps as the only alternative to heart transplantation. The clinically used mechanical devices are associated with severe adverse events, which are reflected here in a comprehensive list of critical requirements for soft active devices of the future: low power, no blood contact, pulsatile support, physiological responsiveness, high cycle life, and less-invasive implantation. In this review, we investigate and critically evaluate prior art in artificial muscles for their applicability in the short and long term. We highlight the main challenges regarding the effectiveness, controllability, and implantability of recently proposed actuators and explore future perspectives for attachment, physiological responsiveness, durability, and biodegradability as well as equitable design considerations.
  •  
4.
  • Pirozzi, Ileana, et al. (author)
  • RVEX : Right Ventricular External Device for Biomimetic Support and Monitoring of the Right Heart
  • 2022
  • In: Advanced Materials Technologies. - : Wiley. - 2365-709X. ; 7:8, s. 2101472-2101472
  • Journal article (peer-reviewed)abstract
    • Right ventricular (RV) failure remains a significant burden for patients with advanced heart failure, especially after major cardiac surgeries such as implantation of left ventricular assist devices. Device solutions that can assist the complex biological function of heart muscle without the disadvantages of bulky designs and infection-prone drivelines remain an area of pressing clinical need, especially for the right ventricle. In addition, devices that incur contact between blood and artificial surfaces mandate long-term use of blood-thinning medications, carrying increased risks for the patients. This work describes the design of a biomimetic, elastic sleeve to support RV-specific motion via tuned regional mechanical properties. The RV external device (RVEX) in computational models as well as benchtop models and ex vivo (i.e., explanted heart) setups are evaluated to characterize the device and predict functional benefit. Additionally, long-term implantation potential is demonstrated in mice. Finally, the ability to sensorize the RVEX device to yield resistive self-sensing capabilities to continuously monitor ventricular deformation, as demonstrated in benchtop experiments and in live animal surgeries, is proposed.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view