SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Donaldsson S) "

Sökning: WFRF:(Donaldsson S)

  • Resultat 1-10 av 19
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baldursdottir, S, et al. (författare)
  • Basic principles of neonatal bubble CPAP: effects on CPAP delivery and imposed work of breathing when altering the original design
  • 2020
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 105:5, s. 550-554
  • Tidskriftsartikel (refereegranskat)abstract
    • The original bubble continuous positive airway pressure (bCPAP) design has wide-bore tubing and a low-resistance interface. This creates a stable airway pressure that is reflected by the submersion depth of the expiratory tubing. Several systems with alterations to the original bCPAP design are now available. Most of these are aimed for use in low-income and middle-income countries and have not been compared with the original design.ObjectiveWe identified three major alterations to the original bCPAP design: (1) resistance of nasal interface, (2) volume of dead space and (3) diameter of expiratory tubing. Our aim was to study the effect of these alterations on CPAP delivery and work of breathing in a mechanical lung model. Dead space should always be avoided and was not further tested.MethodsThe effect of nasal interface resistance and expiratory tubing diameter was evaluated with simulated breathing in a mechanical lung model without interface leakage. The main outcome was delivered CPAP and imposed work of breathing.ResultsHigh-resistance interfaces and narrow expiratory tubing increased the work of breathing. Additionally, narrow expiratory tubing resulted in higher CPAP levels than indicated by the submersion depth.ConclusionOur study shows the significant effect on CPAP delivery and imposed work of breathing when using high-resistance interfaces and narrow expiratory tubing in bCPAP systems. New systems should include low-resistance interfaces and wide-bore tubing and be compared with the original bCPAP. Referring to all systems that bubble as bCPAP is misleading and potentially hazardous.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Falk, M, et al. (författare)
  • Interface leakage during neonatal CPAP treatment: a randomised, cross-over trial
  • 2021
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 106:6, s. F663-F667
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine leakage for two neonatal continuous positive airway pressure (CPAP) interfaces and evaluate leak-corrective manoeuvres.DesignThe ToNIL (Trial of NCPAP Interface Leakage) study was a randomised, clinical, cross-over trial with data collection between August 2018 and October 2019. The primary outcome was blinded to the treating staff.SettingOne secondary, 8-bed neonatal intensive care unit (NICU) and three larger (>15 beds), academic NICU referral centres.PatientsNewborn infants with CPAP were screened (n=73), and those with stable spontaneous breathing, low oxygen requirement, postmenstrual age (PMA) over 28 weeks and no comorbidities were eligible. In total, 50 infants were included (median PMA 33 completed weeks).InterventionsLeakage was measured for both prongs and nasal mask, before and after leak-corrective manoeuvres. Interface application was performed in a randomised order by a nurse, blinded to the measured leakage.Main outcome measures30 s average leakage, measured in litres per minute (LPM).ResultsAnalyses showed a significantly lower leakage (mean difference 0.86 LPM, 95% CI 0.07 to 1.65) with prongs (median 2.01 LPM, IQR 1.00–2.80) than nasal mask (median 2.45 LPM, IQR 0.99–5.11). Leak-corrective manoeuvres reduced leakage significantly for both prongs (median 1.22 LPM, IQR 0.54–1.87) and nasal mask (median 2.35 LPM, IQR 0.76–4.75).ConclusionsLarge leakages were common for both interfaces, less with prongs. Simple care manoeuvres reduced leakage for both interfaces. This is the first report of absolute leakage for nasal interfaces and should encourage further studies on leakage during CPAP treatment.
  •  
7.
  •  
8.
  • Gunnarsdottir, K, et al. (författare)
  • Do newborn infants exhale through the CPAP system? Secondary analysis of a randomised cross-over trial
  • 2023
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 108:3, s. 232-236
  • Tidskriftsartikel (refereegranskat)abstract
    • During nasal continuous positive airway pressure (nCPAP) treatment in neonates, leakage is inevitable and can lead to reduced distending pressure in the lungs of the infant. In current practice, neither leakage nor expiratory flow is measured, which makes it difficult to assess if exhalation is through the device or entirely through leakages.ObjectiveTo examine if infants treated with nCPAP exhale through the CPAP system.Design and settingSecondary data analyses from the ToNIL trial on leakages during nCPAP treatment. We retrospectively examined respiratory curves for the 50 infants included in the trial, using NI LabVIEW 2015. Each infant was measured with both prongs and nasal masks. A flow recording was classified as exhalation through the system if more than 50% of all expirations showed reverse flow, each for a minimum duration of 0.1 s.Patients50 infants were included, born with a mean gestational age (GA) of 34 weeks, median birth weight of 1948 g and mean age at measurement 6.5 days. Inclusion criteria were CPAP treatment and a postmenstrual age (PMA) of 28–42 weeks.ResultsIn our measurements, 32/50 infants exhaled through the CPAP system in at least one recording with either nasal mask or prongs. Leakages exceeding 0.3 L/min were seen in 97/100 recordings.ConclusionsDuring nCPAP treatment, infants can exhale through the CPAP system and leakage was common. Measuring expiratory flows and leakages in clinical settings could be valuable in optimising CPAP treatment of infants.Trial registration numberNCT03586856.
  •  
9.
  • Donaldsson, S, et al. (författare)
  • COVID-19: minimising contaminated aerosol spreading during CPAP treatment
  • 2020
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 105:6, s. F669-F671
  • Tidskriftsartikel (refereegranskat)abstract
    • The COVID-19 pandemic has raised concern for healthcare workers getting infected via aerosol from non-invasive respiratory support of infants. Attaching filters that remove viral particles in air from the expiratory limb of continuous positive airway pressure (CPAP) devices should theoretically decrease the risk. However, adding filters to the expiratory limb could add to expiratory resistance and thereby increase the imposed work of breathing (WOB).ObjectiveTo evaluate the effects on imposed WOB when attaching filters to the expiratory limb of CPAP devices.MethodsTwo filters were tested on three CPAP systems at two levels of CPAP in a mechanical lung model. Main outcome was imposed WOB.ResultsThere was a minor increase in imposed WOB when attaching the filters. The differences between the two filters were small.ConclusionTo minimise contaminated aerosol generation during CPAP treatment, filters can be attached to expiratory tubing with only a minimal increase in imposed WOB in a non-humidified environment. Care has to be taken to avoid filter obstruction and replace filters as recommended.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy