SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Gong Nan Jie) "

Search: WFRF:(Gong Nan Jie)

  • Result 1-1 of 1
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Chen, Hanwei, et al. (author)
  • Tumor Volumes Measured From Static and Dynamic F-18-fluoro-2-deoxy-D-glucose Positron Emission Tomography-Computed Tomography Scan : Comparison of Different Methods Using Magnetic Resonance Imaging as the Criterion Standard
  • 2014
  • In: Journal of computer assisted tomography. - 0363-8715 .- 1532-3145. ; 38:2, s. 209-215
  • Journal article (peer-reviewed)abstract
    • Objective: The objective of this study was to compare the accuracy of calculating the primary tumor volumes using a gradient-based method and fixed threshold methods on the standardized uptake value (SUV) maps and the net influx of FDG (Ki) maps from positron emission tomography-computed tomography (PET-CT) images. Materials and Methods: Newly diagnosed patients with head and neck cancer were recruited, and dynamic PET-CT scan and T2-weighted magnetic resonance imaging were performed. The maps of Ki and SUV were calculated from PET-CT images. The tumor volumes were calculated using a gradient-based method and a fixed threshold method at 40% of maximal SUV or maximal Ki. Four kinds of volumes, VOLKi-Gra (from the Ki maps using the gradient-based method), VOLKi-40% (from the Ki maps using the threshold of 40% maximal Ki), VOLSUV-Gra (from the SUV maps using the gradient-based method), and VOLSUV-40% (from the SUV maps using the threshold of 40% maximal SUV), were acquired and compared with VOLMRI (the volumes acquired on T2-weighted images) using the Pearson correlation, paired t test, and similarity analysis. Results: Eighteen patients were studied, of which 4 had poorly defined tumors (PDT). The positron emission tomography-derived volumes were as follows: VOLSUV-40%, 2.1 to 41.2 cm(3) (mean [SD], 12.3 [10.6]); VOLSUV-Gra, 2.2 to 28.1 cm(3) (mean [SD], 13.2 [8.4]); VOLKi-Gra, 2.4 to 17.0 cm(3) (mean [SD], 9.5 [4.6]); and VOLKi-40%, 2.7 to 20.3 cm(3) (mean [SD], 12.0 [6.0]). The VOLMRI ranged from 2.9 to 18.1 cm(3) (mean [SD], 9.1 [3.9]). The VOLKi-Gra significantly correlated with VOLMRI with the highest correlation coefficient (PDT included, R = 0.673, P = 0.002; PDT excluded, R = 0.841, P < 0.001) and presented no difference from VOLMRI (P = 0.672 or 0.561, respectively, PDT included and excluded). The difference between VOLKi-Gra and VOLMRI was also the smallest. Conclusions: The tumor volumes delineated on the Ki maps using the gradient-based method are more accurate than those on the SUV maps and using the fixed threshold methods.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-1 of 1
Type of publication
journal article (1)
Type of content
peer-reviewed (1)
Author/Editor
Axelsson, Jan (1)
Chen, Hanwei (1)
Jiang, Jinzhao (1)
Gao, Junling (1)
Liu, Dan (1)
Cui, Minyi (1)
show more...
Gong, Nan-Jie (1)
Feng, Shi-Ting (1)
Luo, Liangping (1)
Huang, Bingsheng (1)
show less...
University
Umeå University (1)
Language
English (1)
Research subject (UKÄ/SCB)
Engineering and Technology (1)
Medical and Health Sciences (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view