SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Gustafsson F. Parnefjord) "

Search: WFRF:(Gustafsson F. Parnefjord)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Hashimoto, T., et al. (author)
  • Beamline test of a transition-edge-sensor spectrometer in preparation for kaonic-atom measurements
  • 2017
  • In: IEEE Transactions on Applied Superconductivity. - 1051-8223. ; 27:4
  • Journal article (peer-reviewed)abstract
    • We are developing a new technique to apply transition-edge sensors (TESs) to X-ray spectroscopy of exotic atoms, especially of kaonic atoms. To demonstrate the feasibility of this pioneering project, performance of a TES-based X-ray detector was evaluated in pion- and kaon-beam environments at particle accelerators.We successfully observed X-rays from pionic-carbon atoms with a resolution as good as 7 eV FWHM at 6 keV. Also at a kaon beamline, we confirmed that the TES spectrometer will be able to achieve our resolution goal, 6 eV, in our first scientific campaign to measure X-rays from kaonic-helium atoms.
  •  
2.
  • Hashimoto, T., et al. (author)
  • Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters
  • 2017
  • In: Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015). - 9784890271221 ; 17
  • Conference paper (peer-reviewed)abstract
    • We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.
  •  
3.
  • Uhlig, Jens, et al. (author)
  • High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential.
  • 2015
  • In: Journal of Synchrotron Radiation. - 1600-5775. ; 22:Pt 3, s. 766-775
  • Journal article (peer-reviewed)abstract
    • X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view