SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Höglund I.) "

Search: WFRF:(Höglund I.)

  • Result 1-10 of 50
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Anastasopoulos, M., et al. (author)
  • Multi-Grid detector for neutron spectroscopy : Results obtained on time-of-flight spectrometer CNCS
  • 2017
  • In: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 12:4
  • Journal article (peer-reviewed)abstract
    • The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3He detectors on an operational instrument. The demonstrator has an active area of 0.2 m2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by 3He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
  •  
2.
  • Saunois, M., et al. (author)
  • The global methane budget 2000–2012
  • 2016
  • In: Earth System Science Data. - : Copernicus GmbH. - 1866-3508 .- 1866-3516. ; 8:2, s. 697-751
  • Journal article (peer-reviewed)abstract
    • The global methane (CH4) budget is becoming an increasingly important component for managing realistic pathways to mitigate climate change. This relevance, due to a shorter atmospheric lifetime and a stronger warming potential than carbon dioxide, is challenged by the still unexplained changes of atmospheric CH4 over the past decade. Emissions and concentrations of CH4 are continuing to increase, making CH4 the second most important human-induced greenhouse gas after carbon dioxide. Two major difficulties in reducing uncertainties come from the large variety of diffusive CH4 sources that overlap geographically, and from the destruction of CH4 by the very short-lived hydroxyl radical (OH). To address these difficulties, we have established a consortium of multi-disciplinary scientists under the umbrella of the Global Carbon Project to synthesize and stimulate research on the methane cycle, and producing regular (∼ biennial) updates of the global methane budget. This consortium includes atmospheric physicists and chemists, biogeochemists of surface and marine emissions, and socio-economists who study anthropogenic emissions. Following Kirschke et al. (2013), we propose here the first version of a living review paper that integrates results of top-down studies (exploiting atmospheric observations within an atmospheric inverse-modelling framework) and bottom-up models, inventories and data-driven approaches (including process-based models for estimating land surface emissions and atmospheric chemistry, and inventories for anthropogenic emissions, data-driven extrapolations). For the 2003–2012 decade, global methane emissions are estimated by top-down inversions at 558 Tg CH4 yr−1, range 540–568. About 60 % of global emissions are anthropogenic (range 50–65 %). Since 2010, the bottom-up global emission inventories have been closer to methane emissions in the most carbon-intensive Representative Concentrations Pathway (RCP8.5) and higher than all other RCP scenarios. Bottom-up approaches suggest larger global emissions (736 Tg CH4 yr−1, range 596–884) mostly because of larger natural emissions from individual sources such as inland waters, natural wetlands and geological sources. Considering the atmospheric constraints on the top-down budget, it is likely that some of the individual emissions reported by the bottom-up approaches are overestimated, leading to too large global emissions. Latitudinal data from top-down emissions indicate a predominance of tropical emissions (∼ 64 % of the global budget, < 30° N) as compared to mid (∼ 32 %, 30–60° N) and high northern latitudes (∼ 4 %, 60–90° N). Top-down inversions consistently infer lower emissions in China (∼ 58 Tg CH4 yr−1, range 51–72, −14 %) and higher emissions in Africa (86 Tg CH4 yr−1, range 73–108, +19 %) than bottom-up values used as prior estimates. Overall, uncertainties for anthropogenic emissions appear smaller than those from natural sources, and the uncertainties on source categories appear larger for top-down inversions than for bottom-up inventories and models. The most important source of uncertainty on the methane budget is attributable to emissions from wetland and other inland waters. We show that the wetland extent could contribute 30–40 % on the estimated range for wetland emissions. Other priorities for improving the methane budget include the following: (i) the development of process-based models for inland-water emissions, (ii) the intensification of methane observations at local scale (flux measurements) to constrain bottom-up land surface models, and at regional scale (surface networks and satellites) to constrain top-down inversions, (iii) improvements in the estimation of atmospheric loss by OH, and (iv) improvements of the transport models integrated in top-down inversions. The data presented here can be downloaded from the Carbon Dioxide Information Analysis Center (http://doi.org/10.3334/CDIAC/GLOBAL_METHANE_BUDGET_2016_V1.1) and the Global Carbon Project.
  •  
3.
  • Saunois, M., et al. (author)
  • Variability and quasi-decadal changes in the methane budget over the period 2000–2012
  • 2017
  • In: Atmospheric Chemistry And Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 17:18, s. 11135-11161
  • Journal article (peer-reviewed)abstract
    • Following the recent Global Carbon Project (GCP) synthesis of the decadal methane (CH4) budget over 2000–2012 (Saunois et al., 2016), we analyse here the same dataset with a focus on quasi-decadal and inter-annual variability in CH4 emissions. The GCP dataset integrates results from top-down studies (exploiting atmospheric observations within an atmospheric inverse-modelling framework) and bottom-up models (including process-based models for estimating land surface emissions and atmospheric chemistry), inventories of anthropogenic emissions, and data-driven approaches. The annual global methane emissions from top-down studies, which by construction match the observed methane growth rate within their uncertainties, all show an increase in total methane emissions over the period 2000–2012, but this increase is not linear over the 13 years. Despite differences between individual studies, the mean emission anomaly of the top-down ensemble shows no significant trend in total methane emissions over the period 2000–2006, during the plateau of atmospheric methane mole fractions, and also over the period 2008–2012, during the renewed atmospheric methane increase. However, the top-down ensemble mean produces an emission shift between 2006 and 2008, leading to 22 [16–32] Tg CH4 yr−1 higher methane emissions over the period 2008–2012 compared to 2002–2006. This emission increase mostly originated from the tropics, with a smaller contribution from mid-latitudes and no significant change from boreal regions. The regional contributions remain uncertain in top-down studies. Tropical South America and South and East Asia seem to contribute the most to the emission increase in the tropics. However, these two regions have only limited atmospheric measurements and remain therefore poorly constrained. The sectorial partitioning of this emission increase between the periods 2002–2006 and 2008–2012 differs from one atmospheric inversion study to another. However, all top-down studies suggest smaller changes in fossil fuel emissions (from oil, gas, and coal industries) compared to the mean of the bottom-up inventories included in this study. This difference is partly driven by a smaller emission change in China from the top-down studies compared to the estimate in the Emission Database for Global Atmospheric Research (EDGARv4.2) inventory, which should be revised to smaller values in a near future. We apply isotopic signatures to the emission changes estimated for individual studies based on five emission sectors and find that for six individual top-down studies (out of eight) the average isotopic signature of the emission changes is not consistent with the observed change in atmospheric 13CH4. However, the partitioning in emission change derived from the ensemble mean is consistent with this isotopic constraint. At the global scale, the top-down ensemble mean suggests that the dominant contribution to the resumed atmospheric CH4 growth after 2006 comes from microbial sources (more from agriculture and waste sectors than from natural wetlands), with an uncertain but smaller contribution from fossil CH4 emissions. In addition, a decrease in biomass burning emissions (in agreement with the biomass burning emission databases) makes the balance of sources consistent with atmospheric 13CH4 observations. In most of the top-down studies included here, OH concentrations are considered constant over the years (seasonal variations but without any inter-annual variability). As a result, the methane loss (in particular through OH oxidation) varies mainly through the change in methane concentrations and not its oxidants. For these reasons, changes in the methane loss could not be properly investigated in this study, although it may play a significant role in the recent atmospheric methane changes as briefly discussed at the end of the paper.
  •  
4.
  • Jadersten, M., et al. (author)
  • Targeting SAMHD1 with hydroxyurea in first-line cytarabine-based therapy of newly diagnosed acute myeloid leukaemia: Results from the HEAT-AML trial
  • 2022
  • In: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 292:6, s. 925-940
  • Journal article (peer-reviewed)abstract
    • Background Treatment of newly diagnosed acute myeloid leukaemia (AML) is based on combination chemotherapy with cytarabine (ara-C) and anthracyclines. Five-year overall survival is below 30%, which has partly been attributed to cytarabine resistance. Preclinical data suggest that the addition of hydroxyurea potentiates cytarabine efficacy by increasing ara-C triphosphate (ara-CTP) levels through targeted inhibition of SAMHD1. Objectives In this phase 1 trial, we evaluated the feasibility, safety and efficacy of the addition of hydroxyurea to standard chemotherapy with cytarabine/daunorubicin in newly diagnosed AML patients. Methods Nine patients were enrolled and received at least two courses of ara-C (1 g/m(2)/2 h b.i.d. d1-5, i.e., a total of 10 g/m(2) per course), hydroxyurea (1-2 g d1-5) and daunorubicin (60 mg/m(2) d1-3). The primary endpoint was safety; secondary endpoints were complete remission rate and measurable residual disease (MRD). Additionally, pharmacokinetic studies of ara-CTP and ex vivo drug sensitivity assays were performed. Results The most common grade 3-4 toxicity was febrile neutropenia (100%). No unexpected toxicities were observed. Pharmacokinetic analyses showed a significant increase in median ara-CTP levels (1.5-fold; p = 0.04) in patients receiving doses of 1 g hydroxyurea. Ex vivo, diagnostic leukaemic bone marrow blasts from study patients were significantly sensitised to ara-C by a median factor of 2.1 (p = 0.0047). All nine patients (100%) achieved complete remission, and all eight (100%) with validated MRD measurements (flow cytometry or real-time quantitative polymerase chain reaction [RT-qPCR]) had an MRD level <0.1% after two cycles of chemotherapy. Treatment was well-tolerated, and median time to neutrophil recovery >1.0 x 10(9)/L and to platelet recovery >50 x 10(9)/L after the start of cycle 1 was 19 days and 22 days, respectively. Six of nine patients underwent allogeneic haematopoietic stem-cell transplantation (allo-HSCT). With a median follow-up of 18.0 (range 14.9-20.5) months, one patient with adverse risk not fit for HSCT experienced a relapse after 11.9 months but is now in second complete remission. Conclusion Targeted inhibition of SAMHD1 by the addition of hydroxyurea to conventional AML therapy is safe and appears efficacious within the limitations of the small phase 1 patient cohort. These results need to be corroborated in a larger study.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Stefanescu, I., et al. (author)
  • A B-10-based neutron detector with stacked MultiWire Proportional Counters and macrostructured cathodes
  • 2013
  • In: Journal of Instrumentation. - : Institute of Physics: Hybrid Open Access. - 1748-0221. ; 8
  • Journal article (peer-reviewed)abstract
    • We present the results of the measurements of the detection efficiency for a 4.7 angstrom neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes were made of Aluminum and had a surface exhibiting millimeter-deep V-shaped grooves of 45 degrees, upon which the thin Boron film was deposited by DC magnetron sputtering. The incident neutrons interacting with the converter layer deposited on the sidewalls of the grooves have a higher capture probability, owing to the larger effective absorption film thickness. This leads to a higher overall detection efficiency for the grooved cathode when compared to a cathode with a flat surface. Both the experimental results and the predictions of the GEANT4 model suggests that a 5-counter detector stack with coated grooved cathodes has the same efficiency as a 7-counter stack with flat cathodes. The reduction in the number of counters in the stack without altering the detection efficiency will prove highly beneficial for large-area position-sensitive detectors for neutron scattering applications, for which the cost-effective manufacturing of the detector and associated readout electronics is an important objective. The proposed detector concept could be a technological option for one of the new chopper spectrometers and other instruments planned to be built at the future European Spallation Source in Sweden. These results with macrostructured cathodes generally apply not just to MWPCs but to other gaseous detectors as well.
  •  
9.
  • Stefanescu, I, et al. (author)
  • Development of a novel macrostructured cathode for large-area neutron detectors based on the B-10-containing solid converter
  • 2013
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 727, s. 109-125
  • Journal article (peer-reviewed)abstract
    • We present a novel design for a macrostructured cathode that can be coated with a thin layer of the B-10 solid converter and mounted to replace the Boron-lined flat parallel plates of a proportional counter used for slow neutron detection. The proposed design consists of a 3D regular pattern exhibiting millimeter deep grooves with an opening angle of alpha = 45 degrees, which could be created in the substrate material by milling or forming. When a commonly used coating method like magnetron sputtering is employed to deposit the Boron-layer, due to the line-of-sight distribution of the ions, the thickness of the coating on the side of the grooves will be reduced by a factor similar to sin alpha/2 with respect to the thickness of the layer deposited on a flat surface normal to the ion flux. The effective neutron absorption film thickness is in this case similar for the sidewalls of the grooves and a surface at normal incidence, yielding comparable absorption efficiencies. However, the escape efficiency for the reaction products is higher for the sidewalls, owing to the thinner coating. This leads to a higher overall detection efficiency for the grooved cathode when compared to a flat cathode with the same surface area and coated with a Boron layer with roughly the same thickness. In this paper we present and discuss the GEANT4 simulations performed to optimize the geometry of the cathode, the manufacturing and coating by magnetron sputtering, as well as the proof-of-principle measurements carried out in order to assess the performance of the proposed design.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 50
Type of publication
journal article (37)
conference paper (7)
other publication (2)
doctoral thesis (2)
research review (1)
book chapter (1)
show more...
show less...
Type of content
peer-reviewed (38)
other academic/artistic (12)
Author/Editor
Höglund, Martin (8)
Hall-Wilton, Richard (8)
Robinson, L. (6)
Höglund, C. (5)
Stefanescu, I. (5)
Anastasopoulos, M. (4)
show more...
Bergström, M (4)
Schmidt, Susann (4)
Birch, Jens (4)
Höglund, Carina (4)
Velikyan, I (4)
Piscitelli, F. (4)
Antoni, Gunnar (3)
Hultman, Lars (3)
Hagberg, Hans (3)
Enblad, Gunilla (3)
Thornton, Brett F. (3)
Essand, Magnus (3)
Bastviken, David (3)
Dotti, Gianpietro (3)
Svensson, P (3)
Höglund, Peter (3)
Xu, X. (3)
Zhang, Z. (2)
Peng, C (2)
Kim, H. S. (2)
Weiss, R. (2)
Zhang, B. (2)
Berg, L (2)
Schroeder, R. (2)
Bruhwiler, L. (2)
Ciais, P. (2)
Dlugokencky, E. J. (2)
Varga, D. (2)
Norbäck, Dan (2)
Höglund, Mattias (2)
Hultman, L (2)
Simonsson, Bengt (2)
Dahlman-Höglund, Ann ... (2)
Messi, F. (2)
Janssens-Maenhout, G ... (2)
Savitcheva, I (2)
Öhlén, Joakim, 1958 (2)
Clergeau, J. -F (2)
Van Esch, P. (2)
Guerard, B. (2)
Khaplanov, A. (2)
Lepp, M (2)
Ito, A (2)
Söderberg, Siv (2)
show less...
University
Uppsala University (24)
Lund University (18)
Linköping University (9)
Mid Sweden University (9)
University of Gothenburg (7)
Karolinska Institutet (5)
show more...
Stockholm University (3)
Umeå University (2)
Karlstad University (2)
Royal Institute of Technology (1)
Luleå University of Technology (1)
Halmstad University (1)
Södertörn University (1)
Chalmers University of Technology (1)
Marie Cederschiöld högskola (1)
Swedish University of Agricultural Sciences (1)
show less...
Language
English (47)
Swedish (2)
Undefined language (1)
Research subject (UKÄ/SCB)
Medical and Health Sciences (23)
Natural sciences (19)
Engineering and Technology (6)
Social Sciences (3)
Humanities (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view