SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Halliwell J) "

Search: WFRF:(Halliwell J)

  • Result 1-10 of 15
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  •  
4.
  • Adcox, K, et al. (author)
  • PHENIX detector overview
  • 2003
  • In: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Journal article (peer-reviewed)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
5.
  • Adler, SS, et al. (author)
  • PHENIX on-line systems
  • 2003
  • In: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Journal article (peer-reviewed)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
6.
  •  
7.
  • Murphy, M. P., et al. (author)
  • Guidelines for measuring reactive oxygen species and oxidative damage in cells and in vivo
  • 2022
  • In: Nature Metabolism. - : Springer Science and Business Media LLC. - 2522-5812. ; 4:6, s. 651-662
  • Journal article (peer-reviewed)abstract
    • Multiple roles of reactive oxygen species (ROS) and their consequences for health and disease are emerging throughout biological sciences. This development has led researchers unfamiliar with the complexities of ROS and their reactions to employ commercial kits and probes to measure ROS and oxidative damage inappropriately, treating ROS (a generic abbreviation) as if it were a discrete molecular entity. Unfortunately, the application and interpretation of these measurements are fraught with challenges and limitations. This can lead to misleading claims entering the literature and impeding progress, despite a well-established body of knowledge on how best to assess individual ROS, their reactions, role as signalling molecules and the oxidative damage that they can cause. In this consensus statement we illuminate problems that can arise with many commonly used approaches for measurement of ROS and oxidative damage, and propose guidelines for best practice. We hope that these strategies will be useful to those who find their research requiring assessment of ROS, oxidative damage and redox signalling in cells and in vivo. Reactive oxygen species (ROS) have important roles in health and disease, but are chemically complex and difficult to measure accurately. This consensus statement proposes guidelines and best practices on the nomenclature and assessment of ROS, oxidative reactions and oxidative damage in cells, tissues and in vivo.
  •  
8.
  • Moyroud, Edwige, et al. (author)
  • Cuticle chemistry drives the development of diffraction gratings on the surface of Hibiscus trionum petals
  • 2022
  • In: Current Biology. - : Elsevier BV. - 0960-9822 .- 1879-0445. ; 32:24, s. 5323-5334, 5323-5334.e1-e6
  • Journal article (peer-reviewed)abstract
    • Plants combine both chemical and structural means to appear colorful. We now have an extensive understanding of the metabolic pathways used by flowering plants to synthesize pigments, but the mechanisms remain obscure whereby cells produce microscopic structures sufficiently regular to interfere with light and create an optical effect. Here, we combine transgenic approaches in a novel model system, Hibiscus trionum, with chemical analyses of the cuticle, both in transgenic lines and in different species of Hibiscus, to investigate the formation of a semi-ordered diffraction grating on the petal surface. We show that regulating both cuticle production and epidermal cell growth is insufficient to determine the type of cuticular pattern produced. Instead, the chemical composition of the cuticle plays a crucial role in restricting the formation of diffraction gratings to the pigmented region of the petal. This suggests that buckling, driven by spatiotemporal regulation of cuticle chemistry, could pattern the petal surface at the nanoscale.
  •  
9.
  • Gruber, Jan, et al. (author)
  • Allantoin in human plasma, serum, and nasal-lining fluids as a biomarker of oxidative stress : avoiding artifacts and establishing real in vivo concentrations.
  • 2009
  • In: Antioxidants and Redox Signaling. - 1523-0864 .- 1557-7716. ; 11:8, s. 1767-1776
  • Journal article (peer-reviewed)abstract
    • Urate is the terminal product of purine metabolism in primates, including humans. Urate is also an efficient scavenger of oxidizing species and is thought to be an important antioxidant in human body fluids. Allantoin, the major oxidation product of urate, has been suggested as a candidate biomarker of oxidative stress because it is not produced metabolically. Although urate is converted to allantoin under strongly alkaline pH, such conditions have been used in the past to facilitate extraction of allantoin. We evolved a method for the determination of allantoin concentrations in human plasma and serum by gas chromatography-mass spectrometry without such artifact. With this method, we show that alkaline conditions do indeed cause breakdown of urate, leading to significant overestimation of allantoin concentration in human samples. By using our alternative method, serum samples from 98 volunteers were analyzed, and allantoin levels were found to be significantly lower than was previously reported. The in vivo utility and sensitivity of our method was further evaluated in human nasal-lining fluids. We were able to demonstrate an ozone-induced increase in allantoin, in the absence of increases in either ascorbate or glutathione oxidation products.
  •  
10.
  • Rubertsson, Sten, et al. (author)
  • The Study Protocol for the LINC (LUCAS in Cardiac Arrest) Study : a study comparing conventional adult out-of-hospital cardiopulmonary resuscitation with a concept with mechanical chest compressions and simultaneous defibrillation
  • 2013
  • In: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : BioMed Central Ltd.. - 1757-7241. ; 21:5
  • Journal article (peer-reviewed)abstract
    • Background The LUCAS™ device delivers mechanical chest compressions that have been shown in experimental studies to improve perfusion pressures to the brain and heart as well as augmenting cerebral blood flow and end tidal CO2, compared with results from standard manual cardiopulmonary resuscitation (CPR). Two randomised pilot studies in out-of-hospital cardiac arrest patients have not shown improved outcome when compared with manual CPR. There remains evidence from small case series that the device can be potentially beneficial compared with manual chest compressions in specific situations. This multicentre study is designed to evaluate the efficacy and safety of mechanical chest compressions with the LUCAS™ device whilst allowing defibrillation during on-going CPR, and comparing the results with those of conventional resuscitation. Methods/design This article describes the design and protocol of the LINC-study which is a randomised controlled multicentre study of 2500 out-of-hospital cardiac arrest patients. The study has been registered at ClinicalTrials.gov (http://clinicaltrials.gov/ct2/show/NCT00609778?term=LINC&rank=1 webcite). Results Primary endpoint is four-hour survival after successful restoration of spontaneous circulation. The safety aspect is being evaluated by post mortem examinations in 300 patients that may reflect injuries from CPR. Conclusion This large multicentre study will contribute to the evaluation of mechanical chest compression in CPR and specifically to the efficacy and safety of the LUCAS™ device when used in association with defibrillation during on-going CPR.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view