SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Hellgren Johansson Laila) "

Search: WFRF:(Hellgren Johansson Laila)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Simonson, Oscar E., et al. (author)
  • In Vivo Effects of Mesenchymal Stromal Cells in Two Patients With Severe Acute Respiratory Distress Syndrome
  • 2015
  • In: Stem Cells Translational Medicine. - : Oxford University Press (OUP). - 2157-6564 .- 2157-6580. ; 4:10, s. 1199-1213
  • Journal article (peer-reviewed)abstract
    • Mesenchymal stromal cells (MSCs) have been investigated as a treatment for various inflammatory diseases because of their immunomodulatory and reparative properties. However, many basic questions concerning their mechanisms of action after systemic infusion remain unanswered. We performed a detailed analysis of the immunomodulatory properties and proteomic profile of MSCs systemically administered to two patients with severe refractory acute respiratory distress syndrome (ARDS) on a compassionate use basis and attempted to correlate these with in vivo anti-inflammatory actions. Both patients received 2 x 10(6) cells per kilogram, and each subsequently improved with resolution of respiratory, hemodynamic, and multiorgan failure. In parallel, a decrease was seen in multiple pulmonary and systemic markers of inflammation, including epithelial apoptosis, alveolar-capillary fluid leakage, and proinflammatory cytokines, microRNAs, and chemokines. In vitro studies of the MSCs demonstrated a broad anti-inflammatory capacity, including suppression of T-cell responses and induction of regulatory phenotypes in T cells, monocytes, and neutrophils. Some of these in vitro potency assessments correlated with, and were relevant to, the observed in vivo actions. These experiences highlight both the mechanistic information that can be gained from clinical experience and the value of correlating in vitro potency assessments with clinical effects. The findings also suggest, but do not prove, a beneficial effect of lung protective strategies using adoptively transferred MSCs in ARDS. Appropriate randomized clinical trials are required to further assess any potential clinical efficacy and investigate the effects on in vivo inflammation. STEM CELLS TRANSLATIONAL MEDICINE 2015;4:1199-1213
  •  
3.
  • Ingimarsdottir, I. J., et al. (author)
  • Preoperative aortic annulus size assessment by transthoracic echocardiography compared to the size of surgically implanted aortic prostheses
  • 2019
  • In: ECHO RESEARCH AND PRACTICE. - 2055-0464. ; 6:2, s. 37-41
  • Journal article (peer-reviewed)abstract
    • Objectives: The aortic annulus diameter measured by transthoracic echocardiography yields lower values than by computed tomography, and echo-based selection of transcatheter aortic valve prosthesis size has been implied to result in more frequent paravalvular leakage. We investigated the relation of preoperative annulus diameter by echo with the ring size of the aortic prosthesis chosen by direct assessment during open-heart aortic valve replacement.Methods: Preoperative annulus diameter by echo (from parasternal long-axis cross-sections of the left ventricular outflow tract and aortic valve) and implanted prosthetic diameter (tissue annulus diameter, determined intraoperatively using a sizing instrument) were compared retrospectively in 285 consecutive patients undergoing open-heart aortic valve replacement.Results: A total of 285 prostheses (240 biologic and 45 mechanical) were implanted, with prosthetic diameter ranging between 19 and 27 mm. There was a significant linear correlation (P < 0.0001) with r = 0.51, between preoperative annulus diameter by echo (mean 21.8 +/- 2.8 mm) and prosthetic diameter (22.9 +/- 1.7 mm). Preoperative annulus diameter of patients receiving prostheses no. 21, 23 and 25 mm aortic prostheses (the most frequent prosthesis sizes) were significantly different (P < 0.001) from each other. On average, preoperative annulus diameter by echo underestimated prosthetic diameter by a bias of 1.07 mm.Conclusion: Our data confirm that preoperative echo assessment of the aortic valve may slightly underestimates the optimal surgical prosthesis diameter for the aortic valve annulus.
  •  
4.
  • Lewisson, Niclas, et al. (author)
  • Quality improvement in clinical teaching through student evaluations of rotations and feedback to departments
  • 2013
  • In: Medical teacher. - 0142-159X .- 1466-187X. ; 35:10, s. 820-825
  • Journal article (peer-reviewed)abstract
    • Background: Clinical teaching at medical schools needs continual improvement. We used a new evaluation instrument to gather student ratings on a departmental level across all clinical rotations. The ratings were used to enable cross comparison of departmental clinical teaching quality, official ranking and feedback as a method to improve teaching quality. This study was designed to evaluate whether these interventions increased the quality of clinical teaching. Methods: A web-based questionnaire consisting of 10 questions (Likert scale 1-6) was introduced into all hospital departments at Uppsala University Hospital, Sweden. Specific feedback was given to participating departments based on the assessments collected. Action plans were created in order to address areas for departmental improvement. Questionnaire scores were used as a measure of clinical teaching quality. Results: Mean follow-up time was 2.5 semesters. The student response rate was 70% (n=1981). The departments' median ratings (25th-75th percentile) for the baseline were 4.05 (3.80-4.30). At follow-up, the median rating had increased to 4.56 (4.29-4.72) (p<0.001). Conclusion: The introduction of a uniform clinical teaching evaluation instrument enabled cross comparison between clinical departments. Specific feedback enabled the development of action plans in the departments. This caused a rapid and substantial increase in the quality of clinical teaching.
  •  
5.
  • Vikholm, Per, et al. (author)
  • A modified Glenn shunt improves haemodynamics in acute right ventricular failure in an experimental model
  • 2013
  • In: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 43:3, s. 612-618
  • Journal article (peer-reviewed)abstract
    • OBJECTIVES:Right heart failure is a major cause of morbidity and mortality after left ventricular assist device implantation and is still hard to predict. This study investigated the haemodynamic effect of a modified Glenn shunt on induced right ventricular (RV) failure.METHODS:Isolated RV failure was induced by coronary ligation in 11 pigs. A modified Glenn shunt was established by a superior vena cava to pulmonary artery connection. Haemodynamic data were obtained at baseline, RV failure, and RV failure and open shunt. Myocardial biopsies were taken to ascertain established heart failure.RESULTS:RV failure defined as right atrial pressure ≥20 mmHg was achieved in all 11 animals. A reduction in cardiac output (CO) from 3.7 (3.5-4.2) to 2.3 l/min (2.0-2.6) and mean arterial pressure (MAP) from median 72.7 (70.1-82.2) to 55.9 mmHg (52.6-59.8) was seen during heart failure. The median flow in the shunt was 681 ml. Right atrial pressures decreased from 20.3 (19.6-21.1) to 13.4 mmHg (12.7-14.0), and RV pressures decreased from 18.1 (16.4-20.1) to 13.6 mmHg (13.5-14.2) with open shunt (P = 0.001 for both). CO increased to 2.9 l/min (2.4-3.3) when the shunt was in use. Mixed venous oxygen saturation increased with the shunt from 32 (27-38) to 49% (45-56), P = 0.001. Genes associated with heart failure were upregulated during heart failure.CONCLUSIONS:A modified Glenn shunt improved haemodynamics by reduced right atrial pressure, increased CO, MAP and mixed venous oxygen saturation in an experimental model of induced RV failure.
  •  
6.
  • Vikholm, Per, et al. (author)
  • Cavoaortic shunt improves hemodynamics with preserved oxygen delivery in experimental right ventricular failure during left ventricular assist device therapy
  • 2014
  • In: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 0022-5223 .- 1097-685X. ; 147:2, s. 625-631
  • Journal article (peer-reviewed)abstract
    • OBJECTIVE:Right heart failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) implantation. This study evaluated the approach of a cavoaortic shunt included in the LVAD circuit, which would aim to relieve venous congestion and improve hemodynamics with preserved oxygen delivery during induced right ventricular failure.METHODS:Right ventricular failure was induced by coronary ligation in 10 pigs. An LVAD was implanted and a cavoaortic shunt was created from the right atrium and included in the assist circuit. Hemodynamic measures and blood gas analyses were analyzed. Oxygen delivery and oxygen consumption were estimated.RESULTS:Right atrial pressure decreased from more than 20 mm Hg to 17.2 mm Hg (14.8-18.4) with the LVAD and to 14.1 mm Hg (11.2-15.5) (P < .01) with the LVAD and cavoaortic shunt. Mean arterial pressure increased from 70.9 mm Hg (67.6-79.8) to 81.5 mm Hg (70.8-92.6) (P = .02) with addition of the shunt into the assist circuit. Cardiac output increased from 3.5 L/min (2.6-4.2) to 4.9 L/min (3.5-5.6) (P < .01) with cavoaortic shunting. Oxygen delivery with the cavoaortic shunt was 337 mL/min (±70) as compared with left ventricular assist alone at 258 mL/min (±52) (P < .01). Oxygen consumption was restored during use of the cavoaortic shunt.CONCLUSIONS:A cavoaortic shunt combined with an LVAD during right ventricular failure reduces central venous pressures, increases systemic arterial pressure, and enables increased cardiac output compared with device therapy alone. This was feasible with preserved oxygen delivery.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view