SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Huynh Ba Guy) "

Search: WFRF:(Huynh Ba Guy)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Huynh-Ba, Guy, et al. (author)
  • Analysis of the socket bone wall dimensions in the upper maxilla in relation to immediate implant placement.
  • 2010
  • In: Clinical oral implants research. - : Wiley. - 1600-0501 .- 0905-7161. ; 21:1, s. 37-42
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Animal and human researches have shown that immediate implant placement into extraction sockets failed to prevent socket dimensional changes following tooth extraction. It has been suggested that a minimal width of 1-2 mm of buccal bone is necessary to maintain a stable vertical dimension of the alveolar crest. AIM: To determine the dimensions of the bony wall at extraction sites in the esthetic zone (anterior teeth and premolars in the maxilla) and relate it to immediate implant placement. METHODS: As part of an ongoing prospective randomized-controlled multicenter clinical study on immediate implant placement, the width of the buccal and palatal bony walls was recorded at 93 extraction sites. RESULTS: The mean width of the buccal and palatal bony walls was 1 and 1.2 mm, respectively (P<0.05). For the anterior sites (canine to canine), the mean width of the buccal bony wall was 0.8 mm. For the posterior (premolar) sites, it was 1.1 mm (P<0.05). In the anterior sites, 87% of the buccal bony walls had a width < or = 1 mm and 3% of the walls were 2 mm wide. In the posterior sites, the corresponding values were 59% and 9%, respectively. CONCLUSIONS: If the criterion of a minimal buccal bone width of 2 mm to maintain a stable buccal bony wall is valid, only a limited number of sites in the anterior maxilla display such a clinical situation. The data suggested that in the majority of extraction sites in the anterior maxilla, thin (< or = 1 mm) buccal walls were present. This, in turn, means that in most clinical situations encountered, augmentation procedures are needed to achieve adequate bony contours around the implant.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view