SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Kambe S.) "

Search: WFRF:(Kambe S.)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Bedding, Timothy R., et al. (author)
  • A multi-site campaign to measure solar-like oscillations in Procyon. II. mode frequencies
  • 2010
  • In: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 713:2, s. 935-949
  • Journal article (peer-reviewed)abstract
    • We have analyzed data from a multi-site campaign to observe oscillations in the F5 star Procyon. The data consist of high-precision velocities that we obtained over more than three weeks with 11 telescopes. A new method for adjusting the data weights allows us to suppress the sidelobes in the power spectrum. Stacking the power spectrum in a so-called echelle diagram reveals two clear ridges, which we identify with even and odd values of the angular degree (l = 0 and 2, and l = 1 and 3, respectively). We interpret a strong, narrow peak at 446 mu Hz that lies close to the l = 1 ridge as a mode with mixed character. We show that the frequencies of the ridge centroids and their separations are useful diagnostics for asteroseismology. In particular, variations in the large separation appear to indicate a glitch in the sound-speed profile at an acoustic depth of similar to 1000 s. We list frequencies for 55 modes extracted from the data spanning 20 radial orders, a range comparable to the best solar data, which will provide valuable constraints for theoretical models. A preliminary comparison with published models shows that the offset between observed and calculated frequencies for the radial modes is very different for Procyon than for the Sun and other cool stars. We find the mean lifetime of the modes in Procyon to be 1.29(-0.49)(+0.55) days, which is significantly shorter than the 2-4 days seen in the Sun.
  •  
2.
  •  
3.
  • Ryu, Tsuguru, et al. (author)
  • HIGH-CONTRAST IMAGING OF INTERMEDIATE-MASS GIANTS WITH LONG-TERM RADIAL VELOCITY TRENDS
  • 2016
  • In: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 825:2
  • Journal article (peer-reviewed)abstract
    • A radial velocity (RV) survey for intermediate-mass giants has been in operation for over a decade at Okayama Astrophysical Observatory (OAO). The OAO survey has revealed that some giants show long-term linear RV accelerations (RV trends), indicating the presence of outer companions. Direct-imaging observations can help clarify what objects generate these RV trends. We present the results of high-contrast imaging observations of six intermediate-mass giants with long-term RV trends using the Subaru Telescope and HiCIAO camera. We detected co-moving companions to gamma Hya B (0.61(-0.14)(+0.12)M(circle dot)), HD 5608 B (0.10 +/- 0.01M(circle dot)), and HD 109272 B (0.28 +/- 0.06M(circle dot)). For the remaining targets (iota Dra, 18 Del, and HD 14067), we exclude companions more massive than 30-60 M-Jup at projected separations of 1 ''-7 ''. We examine whether these directly imaged companions or unidentified long-period companions can account for the RV trends observed around the six giants. We find that the Kozai mechanism can explain the high eccentricity of the inner planets iota Dra b, HD 5608 b, and HD 14067 b.
  •  
4.
  • Yamaguchi, M., et al. (author)
  • Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
  • 2004
  • In: Medical and Biological Engineering and Computing. - : Springer. - 0140-0118 .- 1741-0444. ; 42:3, s. 322-327
  • Journal article (peer-reviewed)abstract
    • Development of a non-invasive method for measuring the blood glucose level is an urgent necessity, and putting such a method into practical use will enable some of the physical and mental stress that patients with diabetes have to endure to be removed. To realise a non-invasive blood glucose monitor, the gingival crevicular fluid (GCF) was measured. A GCF-collecting device was developed that was designed to be disposable, biocompatible and small enough to be inserted in the gingival crevice for collection of a sub-microlitre sample of GCF. Also, a high-sensitivity glucose testing tape incorporated in the device was developed. Red laser light in a portable optical device measured the colour density of the testing tape. Standard glucose solutions were used to investigate the measurement accuracy of the GCF glucose monitor and showed a correlation coefficient of R=0.99 (n=20) between the optical density and the glucose levels. The GCF glucose monitor was evaluated on healthy Swedish and Japanese adults (n=10) and both GCF glucose levels (GCFLs) and blood glucose levels (BGLs) were measured in conjunction with meal loads. The GCFLs were about 1/10-1/560 lower than the BGLs. No difference in the range of GCFLs between the Swedish and the Japanese subjects was observed. Therefore it was concluded that physique, body mass index and life-style, such as dietary habit, did not significantly influence the GCFLs. Further, the correlation coefficients of all the subjects were 0.70 and 0.88 with each group. It was suggested that GCF could be used as a method of non-invasive blood glucose measurement.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view