SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(LaBarre P.) "

Search: WFRF:(LaBarre P.)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • LaBarre, P. G., et al. (author)
  • Magnetoquantum oscillations in the specific heat of a topological Kondo insulator
  • 2022
  • In: Journal of Physics. - 0953-8984 .- 1361-648X. ; 34:36
  • Journal article (peer-reviewed)abstract
    • Surprisingly, magnetoquantum oscillations (MQOs) characteristic of a metal with a Fermi surface have been observed in measurements of the topological Kondo insulator SmB6. As these MQO have only been observed in measurements of magnetic torque (dHvA) and not in measurements of magnetoresistance (SdH), a debate has arisen as to whether the MQO are an extrinsic effect arising from rare-earth impurities, defects, and/or aluminum inclusions or an intrinsic effect revealing the existence of charge-neutral excitations. We report here the first observation of MQO in the low-temperature specific heat of SmB6. The observed frequencies and their angular dependence for these flux-grown samples are consistent with previous results based on magnetic torque for SmB6 but the inferred effective masses are significantly larger than previously reported. Such oscillations can only be observed if the MQO are of bulk thermodynamic origin; the measured magnetic-field dependent oscillation amplitude and effective mass allow us to rule out suggestions of an extrinsic, aluminum inclusion-based origin for the MQO.
  •  
2.
  • Ward, C., et al. (author)
  • Determining the Agreement Between an Automated Respiratory Rate Counter and a Reference Standard for Detecting Symptoms of Pneumonia in Children: Protocol for a Cross-Sectional Study in Ethiopia
  • 2020
  • In: Jmir Research Protocols. - : JMIR Publications Inc.. - 1929-0748. ; 9:4
  • Journal article (peer-reviewed)abstract
    • Background: Acute respiratory infections (ARIs), primarily pneumonia, are the leading infectious cause of under-5 mortality worldwide. Manually counting respiratory rate (RR) for 60 seconds using an ARI timer is commonly practiced by community health workers to detect fast breathing, an important sign of pneumonia. However, correctly counting breaths manually and classifying the RR is challenging, often leading to inappropriate treatment. A potential solution is to introduce RR counters, which count and classify RR automatically. Objective: This study aims to determine how the RR count of an Automated Respiratory Infection Diagnostic Aid (ARIDA) agrees with the count of an expert panel of pediatricians counting RR by reviewing a video of the child's chest for 60 seconds (reference standard), for children aged younger than 5 years with cough and/or difficult breathing. Methods: A cross-sectional study aiming to enroll 290 children aged 0 to 59 months presenting to pediatric in- and outpatient departments at a teaching hospital in Addis Ababa, Ethiopia, was conducted. Enrollment occurred between April and May 2017. Once enrolled, children participated in at least one of three types of RR evaluations: (1) agreement-measure the RR count of an ARIDA in comparison with the reference standard, (2) consistency-measure the agreement between two ARIDA devices strapped to one child, and (3) RR fluctuation-measure RR count variability over time after ARIDA attachment as measured by a manual count. The agreement and consistency of expert clinicians (ECs) counting RR for the same child with the Mark 2 ARI timer for 60 seconds was also measured in comparison with the reference standard. Results: Primary outcomes were (1) mean difference between the ARIDA and reference standard RR count (agreement) and (2) mean difference between RR counts obtained by two ARIDA devices started simultaneously (consistency). Conclusions: Study strengths included the design allowing for comparison between both ARIDA and the EC with the reference standard RR count. A limitation is that exactly the same set of breaths were not compared between ARIDA and the reference standard since ARIDA can take longer than 60 seconds to count RR. Also, manual RR counting, even when aided by a video of the child's chest movements, is subject to human error and can result in low interrater reliability. Further work is needed to reach global consensus on the most appropriate reference standard and an acceptable level of agreement to provide ministries of health with evidence to make an informed decision on whether to scale up new automated RR counters.
  •  
3.
  • Baker, K., et al. (author)
  • Automated respiratory rate counter to assess children for symptoms of pneumonia: Protocol for cross-sectional usability and acceptability studies in Ethiopia and Nepal
  • 2020
  • In: JMIR Research Protocols. - : JMIR Publications Inc.. - 1929-0748. ; 9:3
  • Journal article (peer-reviewed)abstract
    • Background: Manually counting a child's respiratory rate (RR) for 60 seconds using an acute respiratory infection timer is the World Health Organization (WHO) recommended method for detecting fast breathing as a sign of pneumonia. However, counting the RR is challenging and misclassification of an observed rate is common, often leading to inappropriate treatment. To address this gap, the acute respiratory infection diagnostic aid (ARIDA) project was initiated in response to a call for better pneumonia diagnostic aids and aimed to identify and assess automated RR counters for classifying fast breathing pneumonia when used by front-line health workers in resource-limited community settings and health facilities. The Children's Automated Respiration Monitor (ChARM), an automated RR diagnostic aid using accelerometer technology developed by Koninklijke Philips NV, and the Rad-G, a multimodal RR diagnostic and pulse oximeter developed by Masimo, were the two devices tested in these studies conducted in the Southern Nations, Nationalities, and Peoples' Region in Ethiopia and in the Karnali region in Nepal. Objective: In these studies, we aimed to understand the usability of two new automated RR diagnostic aids for community health workers (CHWs; health extension workers [Ethiopia] and female community health volunteers [Nepal]) and their acceptability to CHWs in Ethiopia and Nepal, first-level health facility workers (FLHFWs) in Ethiopia only, and caregivers in both Ethiopia and Nepal. Methods: This was a prospective, cross-sectional study with a mixed methods design. CHWs and FLHFWs were trained to use both devices and provided with refresher training on all WHO requirements to assess fast breathing. Immediately after training, CHWs were observed using ARIDA on two children. Routine pneumonia case management consultations for children aged 5 years and younger and the device used for these consultations between the first and second consultations were recorded by CHWs in their patient log books. CHWs were observed a second time after 2 months. Semistructured interviews were also conducted with CHWs, FLHFWs, and caregivers. The proportion of consultations with children aged 5 years and younger where CHWs using an ARIDA and adhered to all WHO requirements to assess fast breathing and device manufacturer instructions for use after 2 months will be calculated. Qualitative data from semistructured interviews will be analyzed using a thematic framework approach. Results: The ARIDA project was funded in November 2015, and data collection was conducted between April and December 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2020. Conclusions: This is the first time the usability and acceptability of automated RR counters in low-resource settings have been evaluated. Outcomes will be relevant for policy makers and are important for future research of this new class of diagnostic aids for the management of children with suspected pneumonia. © Kevin Nicholas Baker, Alice Maurel, Charlotte Ward, Dawit Getachew, Tedila Habte, Cindy McWhorter, Paul LaBarre, Jonas Karlström, Max Petzold, Karin Källander.
  •  
4.
  •  
5.
  • Normand, Philippe, et al. (author)
  • Genome characteristics of facultatively symbiotic Frankia sp. strains reflect host range and host plant biogeography.
  • 2007
  • In: Genome Research. - : Cold Spring Harbor Laboratory. - 1088-9051. ; 17:1, s. 7-15
  • Journal article (peer-reviewed)abstract
    • Soil bacteria that also form mutualistic symbioses in plants encounter two major levels of selection. One occurs during adaptation to and survival in soil, and the other occurs in concert with host plant speciation and adaptation. Actinobacteria from the genus Frankia are facultative symbionts that form N2-fixing root nodules on diverse and globally distributed angiosperms in the "actinorhizal" symbioses. Three closely related clades of Frankia sp. strains are recognized; members of each clade infect a subset of plants from among eight angiosperm families. We sequenced the genomes from three strains; their sizes varied from 5.43 Mbp for a narrow host range strain (Frankia sp. strain HFPCcI3) to 7.50 Mbp for a medium host range strain (Frankia alni strain ACN14a) to 9.04 Mbp for a broad host range strain (Frankia sp. strain EAN1pec.) This size divergence is the largest yet reported for such closely related soil bacteria (97.8%–98.9% identity of 16S rRNA genes). The extent of gene deletion, duplication, and acquisition is in concert with the biogeographic history of the symbioses and host plant speciation. Host plant isolation favored genome contraction, whereas host plant diversification favored genome expansion. The results support the idea that major genome expansions as well as reductions can occur in facultative symbiotic soil bacteria as they respond to new environments in the context of their symbioses.
  •  
6.
  • Ward, C., et al. (author)
  • Usability and acceptability of an automated respiratory rate counter to assess children for symptoms of pneumonia: A cross-sectional study in Ethiopia
  • 2020
  • In: Acta Paediatrica. - : Wiley. - 0803-5253 .- 1651-2227.
  • Journal article (peer-reviewed)abstract
    • Aim Manually counting respiratory rate (RR) is commonly practiced by community health workers to detect fast breathing, an important sign of childhood pneumonia. Correctly counting and classifying breaths manually is challenging, often leading to inappropriate treatment. This study aimed to determine the usability of a new automated RR counter (ChARM) by health extension workers (HEWs), and its acceptability to HEWs, first-level health facility workers (FLHFWs) and caregivers in Ethiopia. Methods A cross-sectional study was conducted in one region of Ethiopia between May and August 2018. A total of 131 HEWs were directly observed conducting 262 sick child consultations after training and 337 after 2 months. Usability was measured as adherence to the WHO requirements to assess fast breathing and device manufacturer instructions for use (IFU). Acceptability was measured through semi-structured interviews. Results After 2 months, HEWs were shown to adhere to the requirements in 74.6% consultations; an increase of 18.6% after training (P < .001). ChARM is acceptable to users and caregivers, with HEWs suggesting that ChARM increased client flow and stating a willingness to use ChARM in future. Conclusion Further research on the performance, cost-effectiveness and implementation of this device is warranted to inform policy decisions in countries with a high childhood pneumonia burden.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view