  • Abtahi, Farhad, 1981- (författare)
  • Aspects of Electrical Bioimpedance Spectrum Estimation
  • 2014
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Electrical bioimpedance spectroscopy (EBIS) has been used to assess the status or composition of various types of tissue, and examples of EBIS include body composition analysis (BCA) and tissue characterisation for skin cancer detection. EBIS is a non-invasive method that has the potential to provide a large amount of information for diagnosis or monitoring purposes, such as the monitoring of pulmonary oedema, i.e., fluid accumulation in the lungs. However, in many cases, systems based on EBIS have not become generally accepted in clinical practice. Possible reasons behind the low acceptance of EBIS could involve inaccurate models; artefacts, such as those from movements; measurement errors; and estimation errors. Previous thoracic EBIS measurements aimed at pulmonary oedema have shown some uncertainties in their results, making it difficult to produce trustworthy monitoring methods. The current research hypothesis was that these uncertainties mostly originate from estimation errors. In particular, time-varying behaviours of the thorax, e.g., respiratory and cardiac activity, can cause estimation errors, which make it tricky to detect the slowly varying behaviour of this system, i.e., pulmonary oedema.The aim of this thesis is to investigate potential sources of estimation error in transthoracic impedance spectroscopy (TIS) for pulmonary oedema detection and to propose methods to prevent or compensate for these errors.   This work is mainly focused on two aspects of impedance spectrum estimation: first, the problems associated with the delay between estimations of spectrum samples in the frequency-sweep technique and second, the influence of undersampling (a result of impedance estimation times) when estimating an EBIS spectrum. The delay between frequency sweeps can produce huge errors when analysing EBIS spectra, but its effect decreases with averaging or low-pass filtering, which is a common and simple method for monitoring the time-invariant behaviour of a system. The results show the importance of the undersampling effect as the main estimation error that can cause uncertainty in TIS measurements.  The best time for dealing with this error is during the design process, when the system can be designed to avoid this error or with the possibility to compensate for the error during analysis. A case study of monitoring pulmonary oedema is used to assess the effect of these two estimation errors. However, the results can be generalised to any case for identifying the slowly varying behaviour of physiological systems that also display higher frequency variations.  Finally, some suggestions for designing an EBIS measurement system and analysis methods to avoid or compensate for these estimation errors are discussed.
  •  
2.
  • Abtahi, Farhad, 1981- (författare)
  • Towards Heart Rate Variability Tools in P-Health : Pervasive, Preventive, Predictive and Personalized
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Heart rate variability (HRV) has received much attention lately. It has been shown that HRV can be used to monitor the autonomic nervous system and to detect autonomic dysfunction, especially vagal dysfunction. Reduced HRV is associated with several diseases and has also been suggested as a predictor of poor outcomes and sudden cardiac death. HRV is, however, not yet widely accepted as a clinical tool and is mostly used for research. Advances in neuroimmunity with an improved understanding of the link between the nervous and immune systems have opened a new potential arena for HRV applications. An example is when systemic inflammation and autoimmune disease are primarily caused by low vagal activity; it can be detected and prognosticated by reduced HRV. This thesis is the result of several technical development steps and exploratory research where HRV is applied as a prognostic diagnostic tool with preventive potential. The main objectives were 1) to develop an affordable tool for the effective analysis of HRV, 2) to study the correlation between HRV and pro-inflammatory markers and the potential degree of activity in the cholinergic anti-inflammatory pathway, and 3) to develop a biofeedback application intended for support of personal capability to increase the vagal activity as reflected in increased HRV. Written as a compilation thesis, the methodology and the results of each study are presented in each appended paper. In the thesis frame/summary chapter, a summary of each of the included papers is presented, grouped by topic and with their connections. The summary of the results shows that the developed tools may accurately register and properly analyse and potentially influence HRV through the designed biofeedback game. HRV can be used as a prognostic tool, not just in traditional healthcare with a focus on illness but also in wellness. By using these tools for the early detection of decreased HRV, prompt intervention may be possible, enabling the prevention of disease. Gamification and serious gaming is a potential platform to motivate people to follow a routine of exercise that might, through biofeedback, improve HRV and thereby health.
  •  
3.
  • Bäcklund, Tomas, 1958- (författare)
  • Wearable systems and sensors for the assessment of motor control : Development and validation of methods for clinical assessment of idiopathic normal pressure hydrocephalus
  • 2021
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Human gait and balance are controlled by automatic processes in the central nervous system, and in sensory and proprioceptive systems. If a disturbance occurs in any of these complex structures, it may lead to balance and gait problems. Equally important are the systems controlling the upper extremity functions where reach, grasp and manipulation skills may be affected. For the neurodegenerative disease idiopathic normal pressure hydrocephalus (iNPH), balance and gait disturbances are cardinal symptoms. Motor control of the upper extremities is also affected. In clinic today, physical impairment of persons with iNPH is commonly visually assessed using subjective, course tests with ordinal scales with the risk of missing minor changes. There is a lack of objective and quantitative ways to measure motor control in daily patient care. The aim of this thesis was to develop and validate tools for objective assessment of parameters that affect motor control in persons with iNPH.Postural stability in stance and walking was assessed using gyroscopes in patients with iNPH, healthy elderly (HE) and patients with ventriculomegaly (VM). Compared to HE, patients with iNPH had reduced postural stability and relied less on vision. iNPH patients also had a lower trunk sway velocity than VM during walking. The gyroscopic system could quantitatively assess postural deficits in iNPH, making it a potentially useful tool for diagnosis and for clinical follow-up. The differences found during gait also suggests that walking, rather than quiet stance, should be further investigated for facilitating differential diagnosis compared to other patient groups with ventriculomegaly.The gait in patients with iNPH is according to guidelines defined as slow, shuffling with a low foot-lift, and wide based. To objectively quantify the latter two features, a system (Striton) was developed in-house to assess the increased distance between the feet and the peak heel-height at the push-off phase of the gait cycle. It was validated in experimental setups, compared to gold standard motion capture systems (MCS), on healthy elderly (HE), through test-retest and day-to-day evaluations, and in four patients with iNPH. Striton demonstrated high correlations, in step-width and in heel-height, compared with the MCS. The mean step-width in the HE was 5.2 ± 0.9 cm (mean±Standard Deviation) and the heel-height 16.7±0.6 cm. Test-retest and day-to-day variations were small, ±0.5 cm in step-width and ±1.2 cm in heel-height, and differences in the parameters were seen between HE and iNPH both before and after surgery. Thus, Striton has the potential of quantitatively assessing gait parameters in HE and iNPH in a valuable manner.
  •  
4.
  • Ferreira, Javier, 1982- (författare)
  • Modular textile-enabled bioimpedance system for personalized health monitoring applications
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • A growing number of factors, including costs, technological advancements, ageing populations, and medical errors, are leading industrialized countries to invest in research on alternative solutions to improve their health-care systems and increase patients’ quality of life. Personal health systems (PHS) examplify the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centered healthcare delivery model toward a preventive and person-centered approach. PHS offer the means to monitor a patient’s health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive biodataacquisition, allowing remote monitoring of treatment and access to the patient’s status. Electrical bioimpedance (EBI) technology is non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. When combined with state-of-the-art advances in sensors and textiles, EBI technologies are fostering the implementation of wearable bioimpedance monitors that use functional garments for personalized healthcare applications. This research work isfocused on the development of wearable EBI-based monitoring systems for ubiquitous health monitoring applications. The monitoring systems are built upon portable monitoring instrumentation and custom-made textile electrode garments.Portable EBI-based monitors have been developed using the latest material technology and advances in system-on-chip technology. For instance, a portable EBI spectrometer has been validated against a commercial spectrometer for total body composition assessment using functional textile electrode garments. The development of wearable EBI-based monitoring units using functional garments and dry textile electrodes for body composition assessment and respiratory monitoring has been shown to be a feasible approach. The availability of these measurement systems indicates progress toward the real implementation of personalized healthcare systems.
  •  
5.
  • Sturm, Dennis (författare)
  • Wireless Multi-Sensor Feedback Systems for SportsPerformance Monitoring : Design and Development
  • 2012
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Wireless applications have become a common part of daily life. Whether it is mobile phones, the Wi-Fi router at home, the keycard which has replaced the car key, a radio frequency identification access system to a building or a Bluetooth headset for your computer or phone, the means of modern wireless data exchange is an omnipresent technology. In sports, the market is in its infancy for wireless, technical applications or gadgets. Only heart rate monitors and GPS watches are currently used by recreational athletes. Even though most of the larger sports equipment companies regularly launch new products related to sports performance monitoring and mobile phone technology, product innovation leaps are rare.In this work the design of a wireless sports performance measurement platform is presented. Using the example of kayaking, this platform is configured as a paddle performance measuring system, the Kayak XL System, which can monitor propulsive paddle force, paddle kinematics and boat velocity, interalia. A common mobile phone platform has been chosen as the user interface for this system. The design approach focussing on user requests, demands and expectations in combination with the process of iterative technical development are unveiled in this thesis. An evaluation of the system is presented and the work is finalised with an overview of further systems which have been designed based on the developed measurement platform. The Kayak XL System is a flexible system designed to be mounted onto any standard kayak paddle and installed in any competition kayak. Versatility, unobtrusiveness and usability were major design concerns. The developed system consists of four modules plus a software which has been designed for Android mobile phones. The phone communicates with each of the four modules trough Bluetooth radio. These four modules are also referred to as nodes and have specific measurement purposes. Two nodes have been designed to measure paddle force and kinematics, one node has the purpose to measure foot stretcher force and boat motion data, and the fourth node enables a more convenient method of calibrating paddle force measurement. The fourth node is therefore only needed prior to performance data acquisition. Results show that paddle and foot stretcher force can be measured with a resolution below 1N after calibration. Installing the paddle nodes on a previously configured paddle without repeated calibration is facilitated with the compromise of a doubled error margin. The default sampling frequency is set to 100 Hz and can, like all system parameters, be configured on the mobile phone. Real-time computation of complex performance parameters is only limited by the phone CPU. The system adds twice 109 g to the paddle and approximately 850 g to the kayak, excluding the mass of the mobile phone
  •  
6.
  • Buendía López, Rubén, 1982- (författare)
  • Model Based Enhancement of Bioimpedance Spectroscopy Analysis : Towards Textile Enabled Applications
  • 2011
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Several signal processing approaches have been developed to overcome the effect of stray capacitances in Electrical Bioimpedance Spectroscopy (EBIS) measurements. EBIS measurements obtained with textile-enabled instrumentation are more vulnerable to stray capacitances. Currently, the most widespread approach for correcting the effect of stray capacitances in EBIS is the time delay ( Td) compensation method, which also has several drawbacks. In this study, the Td method is revisited and its limitations and its lack of a scientific basis are demonstrated. To determine better ways to overcome the effect of stray capacitances, a simplified measurement model is proposed that is based on previous models of artefacts in EBIS measurements described in the literature. The model consists of a current divider with a parasitic capacitance (Cpar) in parallel with the load. Cpar creates a pathway for the measurement current to leak away from the load, provoking a capacitive leakage effect. In this thesis, three approaches with different limitations are proposed to overcome the capacitive leakage effect. The first approach estimates Cpar and subtracts it from the measurements, thus finding the load. Cpar can be estimated because the susceptance of biological tissue is null at infinite frequency. Therefore, at high frequencies, the susceptance of the tissue can be neglected, and the slope of the susceptance of the measurement is Cpar. The accuracy of Cpar depends on the maximum frequency measured and the value of Cpar. Therefore, it may not be possible to accurately estimate small values of Cpar in the typical frequency ranges used in EBIS. The second and third approaches use the Cole fitting process to estimate the Cole parameters, which form the basis for most EBIS applications. Because the conductance of the measurement is free from the effect of Cpar, performing Cole fitting on the conductance avoids the effect of Cpar in the fitting process. With a poor skin-electrode contact, this approach may not be sufficiently accurate. The third approach would be to perform the Cole fitting on the modulus with a reduced upper frequency limit because the modulus and the low-medium frequencies are very robust against the effect of artefacts. In this approach, a slight capacitive leakage effect is unavoidable. Since it is common to find tainted measurements, especially among those obtained with textile-enabled instrumentation, it is important to find viable methods to avoid their effect. The three methods studied showed that they could reduce the effect of tainted measurements.
  •  
7.
  • Lu, Ke (författare)
  • Wearable Solutions for P-Health at Work : Precise, Pervasive and Preventive
  • 2018
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • With a demographic change towards an older population, the structure of the labor force is shifting, and people are expected to work longer within their extended life span. However, for many people, wellbeing has been compromised by work-related problems before they reach the retirement age. Prevention of chronic diseases such as cardiovascular diseases and musculoskeletal disorders is needed to provide a sustainable working life. Therefore, pervasive tools for risk assessment and intervention are needed. The vision is to use wearable technologies to promote a sustainable work life, to be more detailed, to develop a system that integrates wearable technologies into workwear to provide pervasive and precise occupational disease prevention. This thesis presents some efforts towards this vision, including system-level design for a wearable risk assessment and intervention system, as well as specific insight into solutions for in-field assessment of physical workload and technologies to make smart sensing garments. The overall system is capable of providing unobtrusive monitoring of several signs, automatically estimating risk levels and giving feedback and reports to different stakeholders. The performance and usability of current energy expenditure estimation methods based on heart rate monitors and accelerometers were examined in occupational scenarios. The usefulness of impedance pneumography-based respiration monitoring for energy expenditure estimation was explored. A method that integrates heart rate, respiration and motion information using a neuronal network for enhancing the estimation is shown. The sensing garment is an essential component of the wearable system. Smart textile solutions that improve the performance, usability and manufacturability of sensing garments, including solutions for wiring and textile-electronics interconnection as well as an overall garment design that utilizes different technologies, are demonstrated.
  •  
8.
  • Marquez Ruiz, Juan Carlos (författare)
  • Sensor-Based Garments that Enable the Use of Bioimpedance Technology : Towards PersonalizedHealthcare Monitoring.
  • 2013
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Functional garments for physiological sensing purposes have been utilized in several disciplinesi.e. sports, firefighting, military and medical. In most of the cases textile electrodes (Textrodes)embedded in the garment are employed to monitor vital signs and other physiologicalmeasurements. Electrical Bioimpedance (EBI) is a non-invasive and effective technology that canbe used for detection and supervision of different health conditions. In some specific applicationssuch as body composition assessment EBIS has shown encouraging results proving good degreeof effectiveness and reliability. In a similar way Impedance Cardiography (ICG) is anothermodality of EBI primarily concerned with the determination of Stroke Volume SV, indices ofcontractility, and other aspects of hemodynamics.EBI technology in the previously mentioned modalities can benefit from a integration with agarment; however, a successful implementation of EBI technology depends on the goodperformance of textile electrodes. The main weakness of Textrodes is a deficient skin-electrodeinterface which produces a high degree of sensitivity to signal disturbances. This sensitivity canbe reduced with a suitable selection of the electrode material and an intelligent and ergonomicgarment design that ensures an effective skin-electrode contact area.This research work studies the performance of textile electrodes and garments for EBIspectroscopy for Total Body Assessment and Transthoracic Electrical Bioimpedance (TEB) forcardio monitoring. Their performance is analyzed based on impedance spectra, estimation ofparameters, influence of electrode polarization impedance Zep and quality of the signals using asreference Ag/AgCl electrodes. The study includes the analysis of some characteristics of thetextile electrodes such as conductive material, skin-electrode contact area size and fabricconstruction.The results obtained in this research work present evidence that textile garments with a dry skinelectrodeinterface like the ones used in research produce reliable EBI measurements in bothmodalities: BIS for Total Body Assessment and TEB for Impedance Cardiography. Textiletechnology, if successfully integrated, may enable the utilization of EBI in both modalities andconsequently implementing wearable applications for home and personal health monitoring.
  •  
9.
  • Rattfält, Linda, 1979- (författare)
  • Smartware electrodes for ECG measurements : Design, evaluation and signal processing
  • 2013
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this thesis work has been to study textile and screen printed smartware electrodes for electrocardiographic (ECG) measurements both in terms of their electrode properties and possibility to further improve their robustness to movement induced noise by using signal processing. Smartware electrodes for ECG measurements have previously been used in various applications but basic electrical electrode properties have not sufficiently been looked into. Furthermore, we believe that there is a possibility to reduce disturbances in the smartware ECG by adding redundant sensors and applying sensor fusion signal processing.Electrical properties of conductive textiles have been evaluated in terms of stability and electrode impedance. Three yarns and textile electrode surfaces were tested. The electrodes made from pure stainless steel and 50\% stainless steel/ 50\% polyester showed acceptable stability of electrode potentials. All electrode measurements were performed on skin.Furthermore, we produced six screen printed electrodes and their electrical performance was investigated in an electrochemical cell. The tested inks contained carbon or silver particles in the conduction lines, and Ag/AgCl particles in the electrode surface. Results show that all electrodes were stable in time, with a maximum drift of a few mV during 30 minutes. The silver ink is superior to the carbon based in terms of electrode impedance at the higher frequencies.To extract viable physiological information from noisy signals, canonical correlation analysis (CCA) was applied on multi-channel ECG signals recorded with textile electrodes. Using CCA to solve the blind source separation (BSS) problem, we intended to separate the ECG signal from the various noise sources. The method (CCABSS) was compared to averaging of the ECG channels and to the independent component analysis method (ICA). In the dataset consisting of noisy ECG recordings, the signal was uninterpretable in 7% after CCABSS. Corresponding values for averaging and ICA were 33% and 17%, respectively.Smartware applications often include heartbeat detection while moving, a measurement situation which is prone to produce noise corrupted ECG signals. To compensate for this, we used an event detector based on a multi-channel input, a model of the event and weighted correlation. For measurements at rest and static muscle tension, the sensitivity of the event detector was 97% and 77% respectively. Corresponding values for the golden standard detector Pan-Tompkins were 96% and 52%, respectively. 
  •  
10.
  • Seoane, Fernando, 1976- (författare)
  • Electrical Bioimpedance Cerebral Monitoring : Effects of Hypoxia
  • 2005
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Electrical bioimpedance spectroscopy is one way to study the electrical properties of biological matter. Different applications of electrical bioimpedance measurements have already been used in both research and clinical scenarios i.e. impedance plethysmography, total body water contents, etc. The electrical properties of tissue reflect the electrical characteristics of the constituent elements of the tissue and depend on its structure. Thus study of the electrical properties not only makes it possible to differentiate among tissues but also to determine the tissue condition. During hypoxia/ischemia the cell activates a certain chain of mechanisms of cellular adaptation in response to the insult. A consequence of these response mechanisms is that the biochemical composition of the cellular environment is altered and the cells swell (cellular edema). These alterations affect the electrical properties of tissue and the changes can be observed through measurement of the electrical bioimpedance of the affected tissue. Based on these ideas, this research work studies the effects of hypoxia/ischemia on the brain electrical impedance. The aim is to obtain the fundamental knowledge that may lead to the development of useful clinical tools for cerebral monitoring based on electrical bioimpedance spectroscopy. 
  •  