SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Orlandi D) "

Search: WFRF:(Orlandi D)

  • Result 1-10 of 38
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Akkoyun, S., et al. (author)
  • AGATA - Advanced GAmma Tracking Array
  • 2012
  • In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087 .- 1872-9576. ; 668, s. 26-58
  • Journal article (peer-reviewed)abstract
    • The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector- response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer. © 2011 Elsevier B.V. All rights reserved.
  •  
3.
  • Aprile, E., et al. (author)
  • The XENON1T dark matter experiment
  • 2017
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 77:12
  • Journal article (peer-reviewed)abstract
    • The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
  •  
4.
  • Jentschel, M., et al. (author)
  • EXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility
  • 2017
  • In: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 12
  • Journal article (peer-reviewed)abstract
    • In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of gamma-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) ns(-1)cm(2) at the target position and negligible neutron halo. The targetwas surrounded by an array of eight to ten anti-Compton shielded EXOGAMClover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectorswere arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 x 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico-to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of Ba-133, Co-60 and Eu-152 as well as data from the reactions Al-27(n, gamma)Al-28 and Cl-35(n,gamma)Cl-36 in the energy range from 30 keV up to 10MeV.
  •  
5.
  •  
6.
  • Louchart, C., et al. (author)
  • Collective nature of low-lying excitations in Zn-70,Zn-72,Zn-74 from lifetime measurements using the AGATA spectrometer demonstrator
  • 2013
  • In: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 87:5
  • Journal article (peer-reviewed)abstract
    • Background: Neutron-rich nuclei with protons in the fp shell show an onset of collectivity around N=40. Spectroscopic information is required to understand the underlying mechanism and to determine the relevant terms of the nucleon-nucleon interaction that are responsible for the evolution of the shell structure in this mass region. Methods: We report on the lifetime measurement of the first 2(+) and 4(+) states in Zn-70,Zn-72 ,Zn-74 and the first 6(+) state in Zn-72 using the recoil distance Doppler shift method. The experiment was carried out at the INFN Laboratory of Legnaro with the AGATA demonstrator, first phase of the Advanced Gamma Tracking Array of highly segmented, high-purity germanium detectors coupled to the PRISMA magnetic spectrometer. The excited states of the nuclei of interest were populated in the deep inelastic scattering of a Ge-76 beam impinging on a U-238 target. Results: The maximum of collectivity along the chain of Zn isotopes is observed for Zn-72 at N=42. An unexpectedly long lifetime of 20(-5.2)(+1.8) ps was measured for the 4(+) state in Zn-74. Conclusions: Our results lead to small values of the B(E2;4(1)(+) -> 21(+))/B(E2;2(1)(+->)0(1)(+)) ratio for Zn-72,Zn-74, suggesting a significant noncollective contribution to these excitations. These experimental results are not reproduced by state-of-the-art microscopic models and call for lifetime measurements beyond the first 2(+) state in heavy zinc and nickel isotopes.
  •  
7.
  • Sahin, E., et al. (author)
  • Shell evolution beyond N=40 : Cu-69,Cu-71,Cu-73
  • 2015
  • In: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 91:3
  • Journal article (peer-reviewed)abstract
    • The level structure of the neutron-rich Cu-69, Cu-71, and Cu-73 isotopes has been investigated by means of multinucleon transfer reactions. The experiment was performed at Laboratori Nazionali di Legnaro using the AGATA Demonstrator array coupled to the PRISMA magnetic spectrometer. Lifetimes of excited states in Cu nuclei were measured with the recoil-distance Doppler-shift method. The resulting electromagnetic matrix elements for transitions from excited states in Cu-69,Cu-71,Cu-73 nuclei are used to assess the collective or single-particle character of these states. The results are compared with predictions of large-scale shell-model calculations, giving further insight into the evolution of the proton pf shell as neutrons fill the 1g(9/2) orbital.
  •  
8.
  • Söderström, Pär-Anders, et al. (author)
  • Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors
  • 2011
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 638:1, s. 96-109
  • Journal article (peer-reviewed)abstract
    • The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected γ-ray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted γ-ray. The γ-ray tracking was used to determine the full energy of the γ-rays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of in the FWHM of the interaction position resolution for the γ-ray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a 30Si beam at 64 MeV on a thin 12C target. Pulse-shape analysis of the digitized detector waveforms and γ-ray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the γ-ray energy and on the energy, axial location and type of the first interaction point, are presented. The FWHM of the interaction position resolution varies roughly linearly as a function of γ-ray energy from 8.5 mm at 250 keV to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the γ-ray energy range from 1.5 to 4 MeV.
  •  
9.
  •  
10.
  • Acciarresi, M., et al. (author)
  • Prestroke CHA(2)DS(2)-VASc Score and Severity of Acute Stroke in Patients with Atrial Fibrillation: Findings from RAF Study
  • 2017
  • In: Journal of Stroke & Cerebrovascular Diseases. - : Elsevier BV. - 1052-3057. ; 26:6, s. 1363-1368
  • Journal article (peer-reviewed)abstract
    • Background and Purpose: The aim of this study was to investigate for a possible association between both prestroke CHA(2)DS(2)-VASc score and the severity of stroke at presentation, as well as disability and mortality at 90 days, in patients with acute stroke and atrial fibrillation (AF). Methods: This prospective study enrolled consecutive patients with acute ischemic stroke, AF, and assessment of prestroke CHA2DS2-VASc score. Severity of stroke was assessed on admission using the National Institutes of Health Stroke Scale (NIHSS) score (severe stroke: NIHSS >= 10). Disability and mortality at 90 days were assessed by the modified Rankin Scale (mRS < 3 or >= 3). Multiple logistic regression was used to correlate prestroke CHA(2)DS(2)-VASc and severity of stroke, as well as disability and mortality at 90 days. Results: Of the 1020 patients included in the analysis, 606 patients had an admission NIHSS score lower and 414 patients higher than 10. At 90 days, 510 patients had mRS >= 3. A linear correlation was found between the prestroke CHA(2)DS(2)-VASc score and severity of stroke (P = .001). On multivariate analysis, CHA(2)DS(2)-VASc score correlated with severity of stroke (P = .041) and adverse functional outcome (mRS = 3) (P = .001). A logistic regression with the receiver operating characteristic graph procedure (C-statistics) evidenced an area under the curve of .60 (P = .0001) for severe stroke. Furthermore, a correlation was found between prestroke CHA(2)DS(2)-VASc score and lesion size. Conclusions: In patients with AF, in addition to the risk of stroke, a high CHA(2)DS(2)-VASc score was independently associated with both stroke severity at onset and disability and mortality at 90 days.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 38

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view