  • Mosca, Andrea, et al. (author)
  • Global standardization of glycated hemoglobin measurement: the position of the IFCC Working Group
  • 2007
  • In: Clinical Chemistry and Laboratory Medicine. - 1434-6621. ; 45:8, s. 1077-1080
  • Journal article (peer-reviewed)abstract
    • The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA1c in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA1c) to achieve international standardization of HbA1c measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA1c recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as beta N1-deoxyfructosyl-hemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA1c recommends maintaining the use of the name HbA1c in clinical practice.
  •  
2.
  • Weykamp, Cas, et al. (author)
  • The IFCC reference measurement system for HbA(1)C: A 6-year progress report
  • 2008
  • In: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:2, s. 240-248
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: The IFCC Reference Measurement System for hemoglobin (Hb)A(1)c (IFCC-RM) has been developed within the framework of metrologic traceability and is embedded in a network of 14 reference laboratories. This paper describes the outcome of 12 intercomparison studies (periodic evaluations to control essential elements of the IFCC-RM). METHODS: Each study included: unknown samples (to test individual network laboratories); known samples (controls); recently manufactured calibrators (to check calculated assigned value); stored calibrators (to test stability) and a calibration-set (to calibrate the IFCC-RM). The unknown samples are measured by use of the IFCC-RM and the designated comparison methods [DCMs; the National Glycohemoglobin Standardization Program (NGSP) in the US, Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/ JSCC) in Japan, and Mono-S in Sweden] are used to investigate the stability of the Master Equation (ME), the relationship between IFCC-RM and DCMs. RESULTS: A total of 105 IFCC-RM data sets were evaluated: 95 were approved, 5 were not, and for 5 no data were submitted. Trend analysis of the MEs, expressed as change in percentage HbA(1)c per year, revealed 0.000% (NGSP, not significant), -0.030%, (JDS/JSCC; significant) and -0.016% (Mono-S; not significant). Evaluation of long-term performance revealed no systematic change over time; 2 laboratories showed significant bias, 1 poor reproducibility. The mean HbA(1)c determined by laboratories performing mass spectrometry (MS) was the same as the mean determined by laboratories using capillary electrophoresis (CE), but the reproducibility at laboratories using CE was better. One batch of new calibrators was not approved. All stored calibrators were stable. CONCLUSION: A sound reference system is in place to ensure continuity and stability of the analytical anchor for HbA(1)c.
  •  