SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rolles Keith) "

Sökning: WFRF:(Rolles Keith)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ekeberg, Tomas, 1983-, et al. (författare)
  • Three-dimensional structure determination with an X-ray laser
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Three-dimensional structure determination of a non-crystalline virus has been achieved from a set of randomly oriented continuous diffraction patterns captured with an X-ray laser. Intense, ultra-short X-ray pulses intercepted a beam of single mimivirus particles, producing single particle X-ray diffraction patterns that are assembled into a three-dimensional amplitude distribution based on statistical consistency. Phases are directly retrieved from the assembled Fourier distribution to synthesize a three-dimensional image. The resulting electron density reveals a pseudo-icosahedral asymmetric virion structure with a compartmentalized interior, within which the DNA genome occupies only about a fifth of the volume enclosed by the capsid. Additional electron microscopy data indicate the genome has a chromatin-like fiber structure that has not previously been observed in a virus. 
  •  
2.
  • Schramm, Christoph, et al. (författare)
  • Primary liver transplantation for autoimmune hepatitis: a comparative analysis of the European Liver Transplant Registry.
  • 2010
  • Ingår i: Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society. - : Ovid Technologies (Wolters Kluwer Health). - 1527-6473. ; 16:4, s. 461-9
  • Tidskriftsartikel (refereegranskat)abstract
    • The principal aim of this study was to compare the probability of and potential risk factors for death and graft loss after primary adult and pediatric liver transplantation in patients undergoing transplantation for autoimmune hepatitis (AIH) to those in patients undergoing transplantation for primary biliary cirrhosis (PBC; used as the reference group) or alcoholic cirrhosis (used as an example of a nonautoimmune liver disease). The 5-year survival of patients undergoing transplantation for AIH (n = 827) was 0.73 [95% confidence interval (CI) = 0.67-0.77]. This was similar to that of patients undergoing transplantation for alcoholic cirrhosis (0.74, 95% CI = 0.72-0.76, n = 6424) but significantly worse than that of patients undergoing transplantation for PBC (0.83, 95% CI = 0.80-0.85, n = 1588). Fatal infectious complications occurred at an increased rate in patients with AIH (hazard ratio = 1.8, P = 0.002 with PBC as the reference). The outcome of pediatric AIH patients was similar to that of adult patients undergoing transplantation up to the age of 50 years. However, the survival of AIH patients undergoing transplantation beyond the age of 50 years (0.61 at 5 years, 95% CI = 0.51-0.70) was significantly reduced in comparison with the survival of young adult AIH patients (0.78 at 18-34 years, 95% CI = 0.70-0.86) and in comparison with the survival of patients of the same age group with PBC or alcoholic cirrhosis. In conclusion, age significantly affects patient survival after liver transplantation for AIH. The increased risk of dying of infectious complications in the early postoperative period, especially above the age of 50 years, should be acknowledged in the management of AIH patients with advanced-stage liver disease who are listed for liver transplantation. It should be noted that not all risk factors relevant to patient and graft survival could be analyzed with the European Liver Transplant Registry database.
  •  
3.
  • Seibert, M. Marvin, et al. (författare)
  • Single mimivirus particles intercepted and imaged with an X-ray laser
  • 2011
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 470:7332, s. 78-81
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray lasers offer new capabilities in understanding the structure of biological systems, complex materials and matter under extreme conditions(1-4). Very short and extremely bright, coherent X-ray pulses can be used to outrun key damage processes and obtain a single diffraction pattern from a large macromolecule, a virus or a cell before the sample explodes and turns into plasma(1). The continuous diffraction pattern of non-crystalline objects permits oversampling and direct phase retrieval(2). Here we show that high-quality diffraction data can be obtained with a single X-ray pulse from a noncrystalline biological sample, a single mimivirus particle, which was injected into the pulsed beam of a hard-X-ray free-electron laser, the Linac Coherent Light Source(5). Calculations indicate that the energy deposited into the virus by the pulse heated the particle to over 100,000 K after the pulse had left the sample. The reconstructed exit wavefront (image) yielded 32-nm full-period resolution in a single exposure and showed no measurable damage. The reconstruction indicates inhomogeneous arrangement of dense material inside the virion. We expect that significantly higher resolutions will be achieved in such experiments with shorter and brighter photon pulses focused to a smaller area. The resolution in such experiments can be further extended for samples available in multiple identical copies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy