SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Sciascia S.) "

Search: WFRF:(Sciascia S.)

  • Result 1-10 of 23
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Amelino-Camelia, G., et al. (author)
  • Physics with the KLOE-2 experiment at the upgraded DA Phi NE
  • 2010
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 68:3-4, s. 619-681
  • Research review (peer-reviewed)abstract
    • Investigation at a f-factory can shed light on several debated issues in particle physics. We discuss: (i) recent theoretical development and experimental progress in kaon physics relevant for the Standard Model tests in the flavor sector, (ii) the sensitivity we can reach in probing CPT and Quantum Mechanics from time evolution of entangled-kaon states, (iii) the interest for improving on the present measurements of non-leptonic and radiative decays of kaons and eta/eta' mesons, (iv) the contribution to understand the nature of light scalar mesons, and (v) the opportunity to search for narrow di-lepton resonances suggested by recent models proposing a hidden dark-matter sector. We also report on the e(+)e(-) physics in the continuum with the measurements of (multi) hadronic cross sections and the study of gamma gamma processes.
  •  
2.
  •  
3.
  •  
4.
  • Archilli, F., et al. (author)
  • Search for a vector gauge boson in phi meson decays with the KLOE detector KLOE-2 Collaboration
  • 2012
  • In: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 706:4-5, s. 251-255
  • Journal article (peer-reviewed)abstract
    • The existence of a light dark force mediator has been tested with the KLOE detector at DA Phi NE. This particle, called U. is searched for using the decay chain phi -> eta U, eta -> pi(+)pi(-)pi(0), U -> e(+)e(-). No evidence is found in 1.5 fb(-1) of data. The resulting exclusion plot covers the mass range 5 < M-U < 470 MeV, setting an upper limit on the ratio between the U boson coupling constant and the One structure constant, alpha'/alpha, of <= 2 x 10(-5) at 90% C.L. for 50 < M-U < 420 MeV.
  •  
5.
  • Anelli, M., et al. (author)
  • Measurement and simulation of neutron detection efficiency in lead-scintillating fiber calorimeters
  • 2009
  • In: Nuclear physics B, Proceedings supplements. - : Elsevier BV. - 0920-5632 .- 1873-3832. ; 197:1, s. 353-357
  • Journal article (peer-reviewed)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE lead-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range [5-175] MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 30% to 50%. This value largely exceeds the estimated 8-15% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. First data-MC comparisons are encouraging and allow to disentangle a neutron halo component in the beam.
  •  
6.
  • Anelli, M., et al. (author)
  • Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
  • 2010
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 617:1-3, s. 107-108
  • Journal article (peer-reviewed)abstract
    • We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.
  •  
7.
  • Anelli, M., et al. (author)
  • Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV
  • 2009
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 598:1, s. 244-247
  • Journal article (peer-reviewed)abstract
    • A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration.
  •  
8.
  • Anelli, M., et al. (author)
  • Measurement of the neutron detection efficiency of a 80% absorber-20% scintillating fibers calorimeter
  • 2011
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 626, s. 67-71
  • Journal article (peer-reviewed)abstract
    • The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
  •  
9.
  • Babusci, D., et al. (author)
  • A new limit on the CP violating decay K-S -> 3 pi(0) with the KLOE experiment
  • 2013
  • In: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 723:1-3, s. 54-60
  • Journal article (peer-reviewed)abstract
    • We have carried out a new direct search for the CP violating decay K-S -> 3 pi(0) with 1.7 fb(-1) of e(+)e(-) collisions collected by the KLOE detector at the Phi-factory DA Phi NE. We have searched for this decay in a sample of about 5.9 x 10(8) KSKL events tagging the K-S by means of the K-L interaction in the calorimeter and requiring six prompt photons. With respect to our previous search, the analysis has been improved by increasing of a factor four the tagged sample and by a more effective background rejection of fake K-S tags and spurious clusters. We find no candidates in data and simulated background samples, while we expect 0.12 standard model events. Normalizing to the number of K-S -> 2 pi(0) events in the same sample, we set the upper limit on BR(K-S -> 3 pi(0)) <= 2.6 x 10(-8) at 90% C.L., five times lower than the previous limit. We also set the upper limit on the eta(000) parameter, vertical bar eta(000)vertical bar <= 0.0088 at 90% C.L., improving by a factor two the latest direct measurement. (c) 2013 Elsevier B.V. All rights reserved.
  •  
10.
  • Babusci, D., et al. (author)
  • Limit on the production of a light vector gauge boson in phi meson decays with the KLOE detector
  • 2013
  • In: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 720:1-3, s. 111-115
  • Journal article (peer-reviewed)abstract
    • We present a new limit on the production of a light dark-force mediator with the KLOE detector at DA Phi NE. This boson, called U, has been searched for in the decay phi -> eta U, U -> e(+)e(-), analyzing the. decay eta -> pi(0)pi(0)pi(0) in a data sample of 1.7 fb(-1). No structures are observed in the e(+)e(-) invariant mass distribution over the background. This search is combined with a previous result obtained from the decay eta -> pi(+)pi(-)pi(0), increasing the sensitivity. We set an upper limit at 90% C.L. on the ratio between the U boson coupling constant and the fine structure constant of alpha'/alpha < 1.7 x 10(-5) for 30 < M-U < 400 MeV and alpha'/alpha <= 8 x 10(-6) for the sub-region 50 < M-U <210 MeV. This result assumes the Vector Meson Dominance expectations for the phi eta gamma* transition form factor. The dependence of this limit on the transition form factor has also been studied.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 23

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view