SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Sourbron Steven) "

Search: WFRF:(Sourbron Steven)

  • Result 1-10 of 14
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Bane, Octavia, et al. (author)
  • Consensus-based technical recommendations for clinical translation of renal BOLD MRI
  • 2020
  • In: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer. - 0968-5243 .- 1352-8661. ; 33:1, s. 199-215
  • Research review (peer-reviewed)abstract
    • Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as >= 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
  •  
2.
  • de Boer, Anneloes, et al. (author)
  • Consensus-Based Technical Recommendations for Clinical Translation of Renal Phase Contrast MRI
  • 2022
  • In: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 55:2, s. 323-335
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool.PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies.STUDY TYPE: Systematic consensus process using a modified Delphi method.POPULATION: Not applicable.SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI.ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated.STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts.RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting.DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI.LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.
  •  
3.
  • Dekkers, Ilona A., et al. (author)
  • Consensus-based technical recommendations for clinical translation of renal T1 and T2 mapping MRI
  • 2020
  • In: Magnetic Resonance Materials in Physics, Biology, and Medicine. - : Springer Science and Business Media LLC. - 1352-8661 .- 0968-5243. ; 33:1, s. 163-176
  • Research review (peer-reviewed)abstract
    • To develop technical recommendations on the acquisition and post-processing of renal longitudinal (T1) and transverse (T2) relaxation time mapping. A multidisciplinary panel consisting of 18 experts in the field of renal T1 and T2 mapping participated in a consensus project, which was initiated by the European Cooperation in Science and Technology Action PARENCHIMA CA16103. Consensus recommendations were formulated using a two-step modified Delphi method. The first survey consisted of 56 items on T1 mapping, of which 4 reached the pre-defined consensus threshold of 75% or higher. The second survey was expanded to include both T1 and T2 mapping, and consisted of 54 items of which 32 reached consensus. Recommendations based were formulated on hardware, patient preparation, acquisition, analysis and reporting. Consensus-based technical recommendations for renal T1 and T2 mapping were formulated. However, there was considerable lack of consensus for renal T1 and particularly renal T2 mapping, to some extent surprising considering the long history of relaxometry in MRI, highlighting key knowledge gaps that require further work. This paper should be regarded as a first step in a long-term evidence-based iterative process towards ever increasing harmonization of scan protocols across sites, to ultimately facilitate clinical implementation.
  •  
4.
  • Dwivedi, Om Prakash, et al. (author)
  • Genome-wide mRNA profiling in urinary extracellular vesicles reveals stress gene signature for diabetic kidney disease
  • 2023
  • In: iScience. - 2589-0042. ; 26:5
  • Journal article (peer-reviewed)abstract
    • Urinary extracellular vesicles (uEV) are a largely unexplored source of kidney-derived mRNAs with potential to serve as a liquid kidney biopsy. We assessed ∼200 uEV mRNA samples from clinical studies by genome-wide sequencing to discover mechanisms and candidate biomarkers of diabetic kidney disease (DKD) in Type 1 diabetes (T1D) with replication in Type 1 and 2 diabetes. Sequencing reproducibly showed >10,000 mRNAs with similarity to kidney transcriptome. T1D DKD groups showed 13 upregulated genes prevalently expressed in proximal tubules, correlated with hyperglycemia and involved in cellular/oxidative stress homeostasis. We used six of them (GPX3, NOX4, MSRB, MSRA, HRSP12 and CRYAB) to construct a transcriptional “stress score” that reflected long-term decline of kidney function and could even identify normoalbuminuric individuals showing early decline. We thus provide workflow and web-resource for studying uEV transcriptomes in clinical urine samples and stress-linked DKD markers as potential early non-invasive biomarkers or drug targets.
  •  
5.
  • Elsharif, Mohamed, et al. (author)
  • Hepatectomy risk assessment with functional magnetic resonance imaging (HEPARIM)
  • 2021
  • In: BMC Cancer. - : BMC. - 1471-2407. ; 21:1
  • Journal article (peer-reviewed)abstract
    • Background: Post hepatectomy liver failure (PHLF) remains a significant risk in patients undergoing curative liver resection for cancer, however currently available PHLF risk prediction investigations are not sufficiently accurate. The Hepatectomy risk assessment with functional magnetic resonance imaging trial (HEPARIM) aims to establish if quantitative MRI biomarkers of liver function & perfusion can be used to more accurately predict PHLF risk and FLR function, measured against indocyanine green (ICG) liver function test. Methods: HEPARIM is an observational cohort study recruiting patients undergoing liver resection of 2 segments or more, prior to surgery patients will have both Dynamic Gadoxetate-enhanced (DGE) liver MRI and ICG testing. Day one post op ICG testing is repeated and R15 compared to the Gadoxetate Clearance (GC) of the future liver remnant (FLR-GC) as measure by preoperative DGE- MRI which is the primary outcome, and preoperative ICG R15 compared to GC of whole liver (WL-GC) as a secondary outcome. Data will be collected from medical records, biochemistry, pathology and radiology reports and used in a multi-variate analysis to the value of functional MRI and derive multivariant prediction models for future validation. Discussion: If successful, this test will potentially provide an efficient means to quantitatively assess FLR function and PHLF risk enabling surgeons to push boundaries of liver surgery further while maintaining safe practice and thereby offering chance of cure to patients who would previously been deemed inoperable. MRI has the added benefit of already being part of the routine diagnostic pathway and as such would have limited additional burden on patients time or cost to health care systems. (Hepatectomy Risk Assessment With Functional Magnetic Resonance Imaging - Full Text View -, n.d.)
  •  
6.
  • Forsgren, Mikael (author)
  • The Non-Invasive Liver Biopsy : Determining Hepatic Function in Diffuse and Focal LiverDisease
  • 2017
  • Doctoral thesis (other academic/artistic)abstract
    • The liver is one of the largest organs within the human body and it handles many vital tasks such as nutrient processing, toxin removal, and synthesis of important proteins. The number of people suffering from chronic liver disease is on the rise, likely due to the present ‘western’ lifestyle. As disease develops in the liver there are pathophysiological manifestations within the liver parenchyma that are both common and important to monitor. These manifestations include inflammation, fatty infiltration (steatosis), excessive scar tissue formation (fibrosis and cirrhosis), and iron loading. Importantly, as the disease progresses there is concurrent loss of liver function. Furthermore, postoperative liver function insufficiency is an important concern when planning surgical treatment of the liver, because it is associated with both morbidity and mortality. Liver function can also be hampered due to drug-induced injuries, an important aspect to consider in drug-development.Currently, an invasive liver needle biopsy is required to determine the aetiology and to stage or grade the pathophysiological manifestations. There are important limitations with the biopsy, which include, risk of serious complications, mortality, morbidity, inter- and intra-observer variability, sampling error, and sampling variability. Cleary, it would be beneficial to be able investigate the pathophysiological manifestations accurately, non-invasively, and on regional level.Current available laboratory liver function blood panels are typically insufficient and often only indicate damage at a late stage. Thus, it would be beneficial to have access to biomarkers that are both sensitive and responds to early changes in liver function in both clinical settings and for the pharmaceutical industry and regulatory agencies.The main aim of this thesis was to develop and evaluate methods that can be used for a ‘non-invasive liver biopsy’ using magnetic resonance (MR). We also aimed to develop sensitive methods for measure liver function based on gadoxetate-enhanced MR imaging (MRI).The presented work is primarily based on a prospective study on c. 100 patients suffering from chronic liver disease of varying aetiologies recruited due to elevated liver enzyme levels, without clear signs of decompensated cirrhosis. Our results show that the commonly used liver fat cut-off for diagnosing steatosis should be lowered from 5% to 3% when using MR proton-density fat fraction (PDFF). We also show that MR elastography (MRE) is superior in staging fibrosis.Finally we presented a framework for quantifying liver function based on gadoxetate-enhanced MRI. The method is based on clinical images and a clinical approved contrast agent (gadoxetate). The framework consists of; state-of the-art image reconstruction and correction methods, a mathematical model, and a precise model parametrization method. The model was developed and validated on healthy subjects. Thereafter the model was found applicable on the chronic liver disease cohort as well as validated using gadoxetate levels in biopsy samples and blood samples. The liver function parameters correlated with clinical markers for liver function and liver fibrosis (used as a surrogate marker for liver function).In summary, it should be possible to perform a non-invasive liver biopsy using: MRI-PDFF for liver fat and iron loading, MRE for liver fibrosis and possibly also inflammation, and measure liver function using the presented framework for analysing gadoxetate-enhanced MRI. With the exception of an MREtransducer no additional hardware is required on the MR scanner. The liver function method is likely to be useful both in a clinical setting and in pharmaceutical trials.
  •  
7.
  • Garpebring, Anders, 1980- (author)
  • Contributions to quantitative dynamic contrast-enhanced MRI
  • 2011
  • Doctoral thesis (other academic/artistic)abstract
    • Background: Dynamic contrast-enhanced MRI (DCE-MRI) has the potential to produce images of physiological quantities such as blood flow, blood vessel volume fraction, and blood vessel permeability. Such information is highly valuable, e.g., in oncology. The focus of this work was to improve the quantitative aspects of DCE-MRI in terms of better understanding of error sources and their effect on estimated physiological quantities. Methods: Firstly, a novel parameter estimation algorithm was developed to overcome a problem with sensitivity to the initial guess in parameter estimation with a specific pharmacokinetic model. Secondly, the accuracy of the arterial input function (AIF), i.e., the estimated arterial blood contrast agent concentration, was evaluated in a phantom environment for a standard magnitude-based AIF method commonly used in vivo. The accuracy was also evaluated in vivo for a phase-based method that has previously shown very promising results in phantoms and in animal studies. Finally, a method was developed for estimation of uncertainties in the estimated physiological quantities. Results: The new parameter estimation algorithm enabled significantly faster parameter estimation, thus making it more feasible to obtain blood flow and permeability maps from a DCE-MRI study. The evaluation of the AIF measurements revealed that inflow effects and non-ideal radiofrequency spoiling seriously degrade magnitude-based AIFs and that proper slice placement and improved signal models can reduce this effect. It was also shown that phase-based AIFs can be a feasible alternative provided that the observed difficulties in quantifying low concentrations can be resolved. The uncertainty estimation method was able to accurately quantify how a variety of different errors propagate to uncertainty in the estimated physiological quantities. Conclusion: This work contributes to a better understanding of parameter estimation and AIF quantification in DCE-MRI. The proposed uncertainty estimation method can be used to efficiently calculate uncertainties in the parametric maps obtained in DCE-MRI.
  •  
8.
  • Gooding, Kim, et al. (author)
  • Prognostic imaging biomarkers for diabetic kidney disease (iBEAt): study protocol
  • 2020
  • In: BMC Nephrology. - : Springer Science and Business Media LLC. - 1471-2369. ; 21:1
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Diabetic kidney disease (DKD) remains one of the leading causes of premature death in diabetes. DKD is classified on albuminuria and reduced kidney function (estimated glomerular filtration rate (eGFR)) but these have modest value for predicting future renal status. There is an unmet need for biomarkers that can be used in clinical settings which also improve prediction of renal decline on top of routinely available data, particularly in the early stages. The iBEAt study of the BEAt-DKD project aims to determine whether renal imaging biomarkers (magnetic resonance imaging (MRI) and ultrasound (US)) provide insight into the pathogenesis and heterogeneity of DKD (primary aim) and whether they have potential as prognostic biomarkers in DKD (secondary aim). METHODS: iBEAt is a prospective multi-centre observational cohort study recruiting 500 patients with type 2 diabetes (T2D) and eGFR ≥30 ml/min/1.73m2. At baseline, blood and urine will be collected, clinical examinations will be performed, and medical history will be obtained. These assessments will be repeated annually for 3 years. At baseline each participant will also undergo quantitative renal MRI and US with central processing of MRI images. Biological samples will be stored in a central laboratory for biomarker and validation studies, and data in a central data depository. Data analysis will explore the potential associations between imaging biomarkers and renal function, and whether the imaging biomarkers improve the prediction of DKD progression. Ancillary substudies will: (1) validate imaging biomarkers against renal histopathology; (2) validate MRI based renal blood flow measurements against H2O15 positron-emission tomography (PET); (3) validate methods for (semi-)automated processing of renal MRI; (4) examine longitudinal changes in imaging biomarkers; (5) examine whether glycocalyx and microvascular measures are associated with imaging biomarkers and eGFR decline; (6) explore whether the findings in T2D can be extrapolated to type 1 diabetes. DISCUSSION: iBEAt is the largest DKD imaging study to date and will provide valuable insights into the progression and heterogeneity of DKD. The results may contribute to a more personalised approach to DKD management in patients with T2D. TRIAL REGISTRATION: Clinicaltrials.gov ( NCT03716401 ).
  •  
9.
  • Karlsson, Markus, 1990- (author)
  • Non-Invasive Characterization of Liver Disease : By Multimodal Quantitative Magnetic Resonance
  • 2019
  • Doctoral thesis (other academic/artistic)abstract
    • There is a large and unmet need for diagnostic tool that can be used to characterize chronic liver diseases (CLD). In the earlier stages of CLD, much of the diagnostics involves performing biopsies, which are evaluated by a histopathologist for the presence of e.g. fat, iron, inflammation, and fibrosis. Performing biopsies, however, have two downsides: i) biopsies are invasive and carries a small but non-negligible risk for serious complications, ii) biopsies only represents a tiny portion of the liver and are thus prone to sampling error. Moreover, in the later stages of CLD, when the disease has progressed far enough, the ability of the liver to perform its basic function will be compromised. In this stage, there is a need for better methods for accurately measuring liver function. Additionally, measures of liver function can also be used when developing new drugs, as biomarkers for drug-induced liver injury (DILI), which is a serious drug-safety issue.Magnetic resonance imaging (MRI) is a non-invasive medical imaging modality, which have shown much promise with regards to characterizing liver disease in all of the abovementioned aspects. The aim of this PhD project was to develop and validate MR-based methods that can be used to non-invasively characterize liver disease.Paper I investigated if R2* mapping, a MR-method for measuring liver iron content, can be confounded by liver fat. The results show fat does affect R2*. The conclusion was therefore that fat must be taken into account when measuring small amounts of liver iron, as a small increase in R2* could be due to either small amounts of iron or large amounts of fat.Paper II examined whether T1 mapping, which is another MR-method, can be used for staging liver fibrosis. The results of previous research have been mixed; some studies have been very promising, whereas other studies have been less promising. Unfortunately, the results in Paper II belongs to the less promising studies.Paper III focused on measuring liver function by dynamic contrast-enhanced MRI (DCEMRI) using a liver specific contrast agent, which is taken up the hepatocytes and excreted to the bile. The purpose of the paper was to extend and validate a method for estimating uptake and efflux rates of the contrast agent. The method had previously only been applied in health volunteers. Paper II showed that the method can be applied to CLD patients and that the uptake of the contrast agent is lower in patients with advanced fibrosis.Paper IV also used studied liver function with DCE-MRI in patients with primary sclerosing cholangitis (PSC). PSC is a CLD where the bile ducts are attacked by the immune system. When diagnosing PSC patients, it is common to use magnetic resonance cholangiopancreatography (MRCP), which is a method for imaging the bile ducts. Paper IV examined if there was any correlation between number and severity of the morphological changes, seen on MRCP, and measures of liver function derived using DCE-MRI. However, the results showed no such correlation. The conclusion was that the results indicates that MRCP should not be used to predict parenchymal function.Paper V developed a method for translating DCE-MRI liver function parameters from rats to humans. This translation could be of value when developing new drugs, as a tool for predicting which drugs might cause drug-induced liver injury.In summary, this thesis has shown that multimodal quantitative MR has a bright future for characterizing liver disease from a range of different aspects.
  •  
10.
  • Kenna, J. Gerry, et al. (author)
  • Noninvasive preclinical and clinical imaging of liver transporter function relevant to drug-induced liver injury
  • 2018
  • In: Methods in Pharmacology and Toxicology. - New York, NY : Springer New York. - 1557-2153 .- 1940-6053. ; , s. 627-651
  • Book chapter (other academic/artistic)abstract
    • Imaging technologies can evaluate many different biological processes in vitro (in cell culture models) and in vivo (in animals and humans), and many are used routinely in investigation of human liver diseases. Some of these methods can help understand liver toxicity caused by drugs in vivo in animals, and drug-induced liver injury (DILI) which arises in susceptible humans. Imaging could aid assessment of the relevance to humans in vivo of toxicity caused by drugs in animals (animal/human translation), plus toxicities observed using in vitro model systems (in vitro/in vivo translation). Technologies and probe substrates for quantitative evaluation of hepatobiliary transporter activities are of particular importance. This is due to the key role played by sinusoidal transporter mediated hepatic uptake in DILI caused by many drugs, plus the strong evidence that inhibition of the hepatic bile salt export pump (BSEP) can initiate DILI. Imaging methods for investigation of these processes are reviewed in this chapter, together with their scientific rationale, and methods of quantitative data analysis. In addition to providing biomarkers for investigation of DILI, such approaches could aid the evaluation of clinically relevant drug–drug interactions mediated via hepatobiliary transporter perturbation.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 14
Type of publication
journal article (8)
doctoral thesis (3)
research review (2)
book chapter (1)
Type of content
peer-reviewed (10)
other academic/artistic (4)
Author/Editor
Hockings, Paul, 1956 (4)
Waterton, John C (3)
Bane, Octavia (3)
Dekkers, Ilona A. (3)
Laustsen, Christoffe ... (3)
Gomez, Maria F (2)
show more...
Eckerbom, Per, 1974- (2)
Hall, Michael E. (2)
Sharma, Kanishka (2)
Attia, Magdy (1)
Tuomi, Tiinamaija (1)
Groop, Leif (1)
Darwich, Adam S. (1)
Pedersen, Michael (1)
Schneider, Jürgen E. (1)
Teh, Irvin (1)
Dahlqvist Leinhard, ... (1)
Arvidsson, Jonathan (1)
Rannikko, Antti (1)
Zetterqvist, Anna (1)
Prasad, Rashmi B. (1)
Groop, Per Henrik (1)
Kechagias, Stergios, ... (1)
Gooding, Kim M. (1)
Mahmutovic Persson, ... (1)
Olsson, Lars E (1)
Haase, Michael (1)
Maziarz, Marlena (1)
Caroli, Anna (1)
Forsblom, Carol (1)
Forsgren, Mikael (1)
Liu, Chunlei (1)
Gottschalk, Michael (1)
Treanor, Darren (1)
Wilson, Daniel (1)
Mendichovszky, Iosif ... (1)
Milani, Bastien (1)
Deux, Jean-Francois (1)
Grenier, Nicolas (1)
Inoue, Tsutomu (1)
Lerman, Lilach O. (1)
Morrell, Glen (1)
Pruijm, Menno (1)
Sadowski, Elizabeth ... (1)
Seeliger, Erdmann (1)
Thoeny, Harriet (1)
Vermathen, Peter (1)
Wang, Zhen J. (1)
Serafin, Zbigniew (1)
Zhang, Jeff L. (1)
show less...
University
Chalmers University of Technology (4)
Linköping University (3)
Lund University (3)
Uppsala University (2)
University of Gothenburg (1)
Umeå University (1)
show more...
Royal Institute of Technology (1)
show less...
Language
English (14)
Research subject (UKÄ/SCB)
Medical and Health Sciences (12)
Engineering and Technology (3)
Natural sciences (2)
Social Sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view