1.
  • Sperzel, J, et al. (author)
  • Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: Clinical experience with atrial capture management
  • 2005
  • In: Heart Rhythm. - : Elsevier BV. - 1547-5271. ; 2:11, s. 1203-1210
  • Journal article (peer-reviewed)abstract
    • BACKGROUND The Medtronic EnPulse (TM) pacemaker incorporates the new atrial capture management (ACM) algorithm to automatically measure atrial capture thresholds and subsequently manage atrial pacing outputs. OBJECTIVES The purpose of this study was to evaluate the clinical performance of ACM. METHODS Two hundred patients with an indication for a dual-chamber pacemaker underwent implantation. ACM thresholds and manually measured atrial pacing thresholds were assessed at follow-up visits. Clinical equivalence was defined as the ACM-measured threshold being within -0.25 V to +0.5 V of the manually measured threshold. The clinician analyzed all ACM measurements performed in-office for evidence of proarrhythmia. RESULTS All 200 implanted patients had a 1-month visit, and validated manual and in-office ACM threshold data were available for 123 patients. The ACM threshold was 0.595 +/- 0.252 V, and the manual threshold was 0.584 +/- 0.233 V. The mean difference was 0.010 V with a 95% confidence interval of (-0.001, 0.021). The mean difference over all visits was 0.011 V. For all patients, the individual threshold differences were within the range of clinical equivalence at all visits. No atrial arrhythmias were observed during 892 ACM tests in 193 patients. CONCLUSION This study demonstrated that the ACM algorithm is safe, accurate, and reliable over time. ACM was demonstrated to be clinically equivalent to the manual atrial threshold test in all patients at 1 month and over the entire follow-up period of up to 6 months. ACM ensures atrial capture, may save time during follow-up, and can be used to manage atrial pacing outputs.
  •  
2.
  • Milasinovic, G, et al. (author)
  • Reduction of RV pacing by continuous optimization of the AV interval
  • 2006
  • In: PACE. - : Wiley. - 1540-8159. ; 29:4, s. 406-412
  • Journal article (peer-reviewed)abstract
    • Background: In patients requiring permanent pacing, preservation of intrinsic ventricular activation is preferred whenever possible. The Search AV+ (SAV+) algorithm in Medtronic EnPulse(TM) dual-chamber pacemakers can increase atrioventricular (AV) intervals to 320 ms in patients with intact or intermittent AV conduction. This prospective, multicenter study compared the percentage of ventricular pacing with and without AV interval extension. Methods: Among 197 patients enrolled in the study, the percentage of ventricular-paced beats was evaluated via device diagnostics at the 1-month follow-up. Patient cohorts were defined by clinician assessment of conduction via a 1:1 AV conduction test at the 2-week follow-up. The observed percentage of ventricular pacing with SAV + ON and the predicted percentage of ventricular pacing with SAV + OFF were determined from the SAV + histogram data for the period between the 2-week and 1-month follow-up visits. Results: Of 197 patients, 110 (55.8%) had intact 1:1 AV conduction, of which 109 had 1-month data. SAV + remained ON in 991109 patients; 10 patients had intrinsic A-V conduction intervals beyond SAV + nominal and therefore SAV + disabled. The mean percentage of ventricular pacing in the 109 patients was SAV+ ON = 23.1% (median 3.7%) versus SAV + OFF = 97.2% (median 99.7%). In 87 patients without 1:1 AV conduction, SAV + was programmed OFF in 6, automatically disabled in 52, and remained ON in 29. In 8 of these patients, 80-100% reduction in ventricular pacing was observed with SAV + ON. Conclusion: The Search AV+ algorithm in the EnPulse pacemaker effectively promotes intrinsic ventricular activation and substantially reduces unnecessary ventricular pacing.
  •  
3.
  • Candinas, R, et al. (author)
  • Impact of fusion avoidance on performance of the automatic threshold tracking feature in dual chamber pacemakers: A multicenter prospective randomized study
  • 2002
  • In: PACE. - : Wiley. - 1540-8159. ; 25:11, s. 1540-1545
  • Journal article (peer-reviewed)abstract
    • The Autocapture algorithm enables automatic capture verification on a beat-by-beat basis by recognizing the evoked response signal following each pacemaker stimulus. The algorithm intends to increase patient safety while decreasing energy consumption. However, the occurrence of fusion beats, particularly during dual chamber pacing, may limit the energy saving effect of Autocapture. The aim of this multicenter, prospective, randomized study was to evaluate the impact of the Fusion Avoidance (FA) algorithm on the incidence of fusion beats. Thirty-eight patients (mean age 69 +/- 13 years) with intrinsic AV conduction who were implanted with an Affinity DR were studied. After programming a PV/AV delay of 120/190 ms, patients were randomized to FA On or Off. Each group was further randomized with respect to activation of the AutoIntrinsic Conduction Search (AICS) algorithm. The total number of beats, ventricular paced beats, fusion beats, backup pulses, and threshold searches were analyzed from 24-hour Holter recordings. The number of total beats was comparable in both FA groups. The number of total ventricular paced beats, fusion beats, backup pulses, and threshold searches were significantly reduced in the FA On group (% reduction: 68% P < 0.001, 75% P < 0.01, 95% P < 0.01, and 94% P < 0.05, respectively). The number of ventricular paced beats with full capture was significantly reduced when AICS was activated (P < 0.05). In conclusion, the FA algorithm substantially reduces the amount of ventricular paced beats, fusion beats, unnecessary backup pulses and threshold searches, and therefore, provides added benefits in energy saving obtained by Autocapture.
  •  
4.
  •  