SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wilmot E. G.) "

Sökning: WFRF:(Wilmot E. G.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Moser, O., et al. (författare)
  • Glucose management for exercise using continuous glucose monitoring (CGM) and intermittently scanned CGM (isCGM) systems in type 1 diabetes: position statement of the European Association for the Study of Diabetes (EASD) and of the International Society for Pediatric and Adolescent Diabetes (ISPAD) endorsed by JDRF and supported by the American Diabetes Association (ADA)
  • 2020
  • Ingår i: Diabetologia. - : Springer Science and Business Media LLC. - 0012-186X .- 1432-0428. ; 63, s. 2501-2520
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (i.e. before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes.
  •  
2.
  • Evans, M., et al. (författare)
  • Use of fast-acting insulin aspart in insulin pump therapy in clinical practice
  • 2019
  • Ingår i: Diabetes, Obesity and Metabolism. - : Wiley. - 1462-8902 .- 1463-1326. ; 21:9, s. 2039-2047
  • Tidskriftsartikel (refereegranskat)abstract
    • Fast-acting insulin aspart (faster aspart) is a novel formulation of insulin aspart (IAsp) containing the additional excipients niacinamide and L-arginine. The improved pharmacological profile and greater early glucose-lowering action of faster aspart compared with IAsp suggests that faster aspart may be advantageous for people with diabetes using continuous subcutaneous insulin infusion (CSII). The recent onset 5 trial was the first to evaluate the efficacy and safety of an ultra-fast-acting insulin in CSII therapy in a large number of participants with type 1 diabetes (T1D). Non-inferiority of faster aspart to IAsp in terms of change from baseline in HbA1c was confirmed, with an estimated treatment difference (ETD) of 0.09% (95% CI, 0.01; 0.17; P < 0.001 for non-inferiority [0.4% margin]). Faster aspart was superior to IAsp in terms of change from baseline in 1-hour post-prandial glucose (PPG) increment after a meal test (ETD [95% CI], −0.91 mmol/L [−1.43; −0.39]; P = 0.001), with statistically significant improvements also at 30 minutes and 2 hours. The overall rate of severe or blood glucose-confirmed hypoglycaemia was not statistically significantly different between treatments, with an estimated rate ratio of 1.00 (95% CI, 0.85; 1.16). A numerical imbalance in severe hypoglycaemic episodes between faster aspart and IAsp was seen in the treatment (21 vs 7) and the 4-week run-in periods (4 vs 0). Experience from clinical practice indicates that all pump settings should be reviewed when initiating faster aspart with CSII, and that the use of continuous glucose monitoring or flash glucose monitoring, along with a good understanding of meal content and bolus type, may also facilitate optimal use. This review summarizes the available clinical evidence for faster aspart administered via CSII and highlights practical considerations based on clinical experience that may help healthcare providers and individuals with T1D successfully initiate and adjust faster aspart with CSII. © 2019 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.
  •  
3.
  • Moser, Othmar, et al. (författare)
  • Glucose management for exercise using continuous glucose monitoring (CGM) and intermittently scannedCGM(isCGM) systems in type 1 diabetes: position statement of the European Association for the Study of Diabetes (EASD) and of the International Society for Pediatric and Adolescent Diabetes (ISPAD) endorsed byJDRFand supported by the American Diabetes Association (ADA)
  • 2020
  • Ingår i: PEDIATRIC DIABETES. - : Hindawi Limited. - 1399-543X .- 1399-5448. ; 21:8, s. 1375-1393
  • Tidskriftsartikel (refereegranskat)abstract
    • Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (ie, before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes.
  •  
4.
  • Pemberton, J. S., et al. (författare)
  • CGM accuracy: Contrasting CE marking with the governmental controls of the USA (FDA) and Australia (TGA): A narrative review
  • 2023
  • Ingår i: Diabetes Obesity & Metabolism. - : Wiley. - 1462-8902 .- 1463-1326. ; 25:4, s. 916-939
  • Tidskriftsartikel (refereegranskat)abstract
    • The National Institute for Clinical Excellence updated guidance for continuous glucose monitoring (CGM) in 2022, recommending that CGM be available to all people living with type 1 diabetes. Manufacturers can trade in the UK with Conformite Europeenne (CE) marking without an initial national assessment. The regulatory process for CGM CE marking, in contrast to the Food and Drug Administration (FDA) and Australian Therapeutic Goods Administration (TGA) process, is described. Manufacturers operating in the UK provided clinical accuracy studies submitted for CE marking. Critical appraisal of the studies shows several CGM devices have CE marking for wide-ranging indications beyond available data, unlike FDA and TGA approval. The FDA and TGA use tighter controls, requiring comprehensive product-specific clinical data evaluation. In 2018, the FDA published the integrated CGM (iCGM) criteria permitting interoperability. Applying the iCGM criteria to clinical data provided by manufacturers trading in the UK identified several study protocols that minimized glucose variability, thereby improving CGM accuracy on all metrics. These results do not translate into real-life performance. Furthermore, for many CGM devices available in the UK, accuracy reported in the hypoglycaemic range is below iCGM standards, or measurement is absent. We offer a framework to evaluate CGM accuracy studies critically. The review concludes that FDA- and TGA-approved indications match the available clinical data, whereas CE marking indications can have discrepancies. The UK can bolster regulation with UK Conformity Assessed marking from January 2025. However, balanced regulation is needed to ensure innovation and timely technological access are not hindered.
  •  
5.
  • Zheng, Hou-Feng, et al. (författare)
  • Whole-genome sequencing identifies EN1 as a determinant of bone density and fracture
  • 2015
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 526:7571, s. 112-
  • Tidskriftsartikel (refereegranskat)abstract
    • The extent to which low-frequency (minor allele frequency (MAF) between 1-5%) and rare (MAF <= 1%) variants contribute to complex traits and disease in the general population is mainly unknown. Bone mineral density (BMD) is highly heritable, a major predictor of osteoporotic fractures, and has been previously associated with common genetic variants(1-8), as well as rare, population specific, coding variants(9). Here we identify novel non-coding genetic variants with large effects on BMD (n(total) = 53,236) and fracture (n(total) = 508,253) in individuals of European ancestry from the general population. Associations for BMD were derived from whole-genome sequencing (n = 2,882 from UK10K (ref. 10); a population-based genome sequencing consortium), whole-exome sequencing (n = 3,549), deep imputation of genotyped samples using a combined UK10K/1000 Genomes reference panel (n = 26,534), and de novo replication genotyping (n = 20,271). We identified a low-frequency non-coding variant near a novel locus, EN1, with an effect size fourfold larger than the mean of previously reported common variants for lumbar spine BMD8 (rs11692564(T), MAF51.6%, replication effect size510.20 s.d., P-meta = 2 x 10(-14)), which was also associated with a decreased risk of fracture (odds ratio = 0.85; P = 2 x 10(-11); ncases = 98,742 and ncontrols = 409,511). Using an En1cre/flox mouse model, we observed that conditional loss of En1 results in low bone mass, probably as a consequence of high bone turnover. We also identified a novel low frequency non-coding variant with large effects on BMD near WNT16 (rs148771817(T), MAF = 1.2%, replication effect size +10.41 s.d., P-meta = 1 x 10(-11)). In general, there was an excess of association signals arising from deleterious coding and conserved non-coding variants. These findings provide evidence that low-frequency non-coding variants have large effects on BMD and fracture, thereby providing rationale for whole-genome sequencing and improved imputation reference panels to study the genetic architecture of complex traits and disease in the general population.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy