SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Artursson P) "

Search: WFRF:(Artursson P)

  • Result 1-25 of 81
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Berglund, U. W., et al. (author)
  • Validation and development of MTH1 inhibitors for treatment of cancer
  • 2016
  • In: Annals of Oncology. - : Elsevier BV. - 0923-7534 .- 1569-8041. ; 27:12, s. 2275-2283
  • Journal article (peer-reviewed)abstract
    • Background: Previously, we showed cancer cells rely on the MTH1 protein to prevent incorporation of otherwise deadly oxidised nucleotides into DNA and we developed MTH1 inhibitors which selectively kill cancer cells. Recently, several new and potent inhibitors of MTH1 were demonstrated to be non-toxic to cancer cells, challenging the utility of MTH1 inhibition as a target for cancer treatment. Material and methods: Human cancer cell lines were exposed in vitro to MTH1 inhibitors or depleted of MTH1 by siRNA or shRNA. 8-oxodG was measured by immunostaining and modified comet assay. Thermal Proteome profiling, proteomics, cellular thermal shift assays, kinase and CEREP panel were used for target engagement, mode of action and selectivity investigations of MTH1 inhibitors. Effect of MTH1 inhibition on tumour growth was explored in BRAF V600E-mutated malignant melanoma patient derived xenograft and human colon cancer SW480 and HCT116 xenograft models. Results: Here, we demonstrate that recently described MTH1 inhibitors, which fail to kill cancer cells, also fail to introduce the toxic oxidized nucleotides into DNA. We also describe a new MTH1 inhibitor TH1579, (Karonudib), an analogue of TH588, which is a potent, selective MTH1 inhibitor with good oral availability and demonstrates excellent pharmacokinetic and anti-cancer properties in vivo. Conclusion: We demonstrate that in order to kill cancer cells MTH1 inhibitors must also introduce oxidized nucleotides into DNA. Furthermore, we describe TH1579 as a best-in-class MTH1 inhibitor, which we expect to be useful in order to further validate the MTH1 inhibitor concept.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  • Prieto, P., et al. (author)
  • The value of selected in vitro and in silico methods to predict acute oral toxicity in a regulatory context : Results from the European Project ACuteTox
  • 2013
  • In: Toxicology in Vitro. - : Elsevier BV. - 0887-2333 .- 1879-3177. ; 27:4, s. 1357-1376
  • Journal article (peer-reviewed)abstract
    • ACuteTox is a project within the 6th European Framework Programme which had as one of its goals to develop, optimise and prevalidate a non-animal testing strategy for predicting human acute oral toxicity. In its last 6 months, a challenging exercise was conducted to assess the predictive capacity of the developed testing strategies and final identification of the most promising ones. Thirty-two chemicals were tested blind in the battery of in vitro and in silico methods selected during the first phase of the project. This paper describes the classification approaches studied: single step procedures and two step tiered testing strategies. In summary, four in vitro testing strategies were proposed as best performing in terms of predictive capacity with respect to the European acute oral toxicity classification. In addition, a heuristic testing strategy is suggested that combines the prediction results gained from the neutral red uptake assay performed in 3T3 cells, with information on neurotoxicity alerts identified by the primary rat brain aggregates test method. Octanol-water partition coefficients and in silico prediction of intestinal absorption and blood-brain barrier passage are also considered. This approach allows to reduce the number of chemicals wrongly predicted as not classified (LD50 > 2000 mg/kg b.w.).
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  • Artursson, Tom, et al. (author)
  • Drift correction for gas sensors using multivariate methods
  • 2000
  • In: Journal of Chemometrics. - 0886-9383 .- 1099-128X. ; 14:5-6, s. 711-723
  • Journal article (peer-reviewed)abstract
    • Drift is one of the most serious impairments afflicting gas sensors. It can be seen as a gradual change in the sensor response over a long period of time when the external conditions an constant. This paper presents a new simple drift counteraction method based on PCA and PLS. The basic idea is to remove the drift direction component from the measurements. The direction of the drift, p, is calculated from measurements for a reference gas. Projecting the sample gas measurements on this vector gives the score vector t. The drift component tp(T) can then he removed from the sample gas data, which we call component correction (CC). The method is tested on a data set based on a reduced factorial design with four gases and a concentration gradient of hydrogen. It is found that the method works efficiently for both cases. Copyright (C) 2000 John Wiley & Sons, Ltd.
  •  
25.
  • Artursson, Tom, et al. (author)
  • Study of Preprocessing Methods for the Determination of Crystalline Phases in Binary Mixtures of Drug Substances by X-ray Powder Diffraction and Multivariate Calibration
  • 2000
  • In: Applied Spectroscopy. - : SAGE Publications. - 0003-7028 .- 1943-3530. ; 54:8, s. 272A-301A
  • Journal article (peer-reviewed)abstract
    • In this paper, various preprocessing methods were tested on data generated by X-ray powder diffraction (XRPD) in order to enhance the partial least-squares (PLS) regression modeling performance. The preprocessing methods examined were 22 different discrete wavelet transforms, Fourier transform, Savitzky-Golay, orthogonal signal correction (OSC), and combinations of wavelet transform and OSC, and Fourier transform and OSC. Root mean square error of prediction (RMSEP) of an independent test set was used to measure the performance of the various preprocessing methods. The best PLS model was obtained with a wavelet transform (Symmlet 8), which at the same time compressed the data set by a factor of 9.5. With the use of wavelet and X-ray powder diffraction, concentrations of less than 10% of one crystal from could be detected in a binary mixture. The linear range was found to be in the range 10-70% of the crystalline form of phenacetin, although semiquantitative work could be carried out down to a level of approximately 2%. Furthermore, the wavelet-pretreated models were able to handle admixtures and deliberately added noise.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-25 of 81

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view