SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Jacobsson U.) "

Search: WFRF:(Jacobsson U.)

  • Result 1-25 of 97
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Abreu, P., et al. (author)
  • Measurement of the gluon fragmentation function and a comparison of the scaling violation in gluon and quark jets
  • 2000
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 13:4, s. 573-589
  • Journal article (peer-reviewed)abstract
    • The fragmentation functions of quarks and gluons are measured in various three-jet topologies in Z decays from the full data set collected with the DELPHI detector at the Z resonance between 1992 and 995. The results at different values of transverse momentum-like scales are compared. A parameterization of the quark and gluon fragmentation functions at a fixed reference scale is given. The quark and gluon fragmentation functions show the predicted pattern of scaling violations. The scaling violation for quark jets as a function of a transverse momentum-like scale is in a good agreement with that observed in lower energy e+e- annihilation experiments. For gluon jets it appears to be significantly stronger. The scale dependences of the gluon and quark fragmentation functions agree with the prediction of the DGLAP evolution equations from which the colour factor ratio CA/CF is measured to be: CA/CF = 2.26 ± 0.09stat. ± 0.06sys. ± 0.12clus.,scale..
  •  
3.
  • Abreu, P., et al. (author)
  • Search for sleptons in e+e- collisions at √s = 183 to 189 GeV
  • 2001
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 19:1, s. 29-42
  • Journal article (peer-reviewed)abstract
    • Data taken by the DELPHI experiment at centre-of-mass energies of 183 GeV and 189 GeV with a total integrated luminosity of 212 pb-1 have been used to search for the supersymmetric partners of the electrons, muons, and taus in the context of the Minimal Supersymmetric Standard Model (MSSM). The decay topologies searched for were the direct decay (ℓ̃ → ℓx̃), producing acoplanar lepton pairs plus missing energy, and the cascade decay (ℓ → ℓx̃0 2 → ℓγx̃0 1), producing acoplanar lepton and photon pairs plus missing energy. The observed number of events is in agreement with Standard Model predictions. The 95% CL excluded mass limits for selectrons, smuons and staus are mẽ ≤ 87 GeV/c2, mμ̃ ≤ 80 GeV/c2 and mτ̃ 75 GeV/c2, respectively, for values of μ=-200 GeV/c2 and tanβ=1.5.
  •  
4.
  • Abreu, P., et al. (author)
  • Study of dimuon production in photon-photon collisions and measurement of QED photon structure functions at LEP
  • 2001
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 19:1, s. 15-28
  • Journal article (peer-reviewed)abstract
    • Muon pair production in the process e+e- → e+e- μ+μ- is studied using the data taken at LEP1 (√s ≃ mz) with the DELPHI detector during the years 1992-1995. The corresponding integrated luminosity is 138.5 pb-1. The QED predictions have been tested over the whole Q2 range accessible at LEP1 (from several GeV2/c4 to several hundred GeV2/c4) by comparing experimental distributions with distributions resulting from Monte Carlo simulations using various generators. Selected events are used to extract the leptonic photon structure function Fγ 2. Azimuthal correlations are used to obtain information on additional structure functions, Fγ A and Fγ B, which originate from interference terms of the scattering amplitudes. The measured ratios Fγ A/Fγ 2 and FγB/Fγ 2 are significantly different from zero and consistent with QED predictions.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Ahdida, C., et al. (author)
  • Fast simulation of muons produced at the SHiP experiment using Generative Adversarial Networks
  • 2019
  • In: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 14
  • Journal article (peer-reviewed)abstract
    • This paper presents a fast approach to simulating muons produced in interactions of the SPS proton beams with the target of the SHiP experiment. The SHIP experiment will be able to search for new long-lived particles produced in a 400 GeV/c SPS proton beam dump and which travel distances between fifty metres and tens of kilometers. The SHiP detector needs to operate under ultra-low background conditions and requires large simulated samples of muon induced background processes. Through the use of Generative Adversarial Networks it is possible to emulate the simulation of the interaction of 400 GeV/c proton beams with the SHiP target, an otherwise computationally intensive process. For the simulation requirements of the SHiP experiment, generative networks are capable of approximating the full simulation of the dense fixed target, offering a speed increase by a factor of O(10(6)). To evaluate the performance of such an approach, comparisons of the distributions of reconstructed muon momenta in SHiP's spectrometer between samples using the full simulation and samples produced through generative models are presented. The methods discussed in this paper can be generalised and applied to modelling any non-discrete multi-dimensional distribution.
  •  
11.
  • Ahdida, C., et al. (author)
  • Measurement of the muon flux from 400 GeV/c protons interacting in a thick molybdenum/tungsten target
  • 2020
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 80:3
  • Journal article (peer-reviewed)abstract
    • The SHiP experiment is proposed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. About 1011muons per spill will be produced in the dump. To design the experiment such that the muon-induced background is minimized, a precise knowledge of the muon spectrum is required. To validate the muon flux generated by our Pythia and GEANT4 based Monte Carlo simulation (FairShip), we have measured the muon flux emanating from a SHiP-like target at the SPS. This target, consisting of 13 interaction lengths of slabs of molybdenum and tungsten, followed by a 2.4 m iron hadron absorber was placed in the H4 400 GeV/c proton beam line. To identify muons and to measure the momentum spectrum, a spectrometer instrumented with drift tubes and a muon tagger were used. During a 3-week period a dataset for analysis corresponding to (3.27 +/- 0.07)x1011protons on target was recorded. This amounts to approximatively 1% of a SHiP spill.
  •  
12.
  • Ahdida, C., et al. (author)
  • Sensitivity of the SHiP experiment to dark photons decaying to a pair of charged particles
  • 2021
  • In: European Physical Journal C. - : Springer Nature. - 1434-6044 .- 1434-6052. ; 81:5
  • Journal article (peer-reviewed)abstract
    • Dark photons are hypothetical massive vector particles that could mix with ordinary photons. The simplest theoretical model is fully characterised by only two parameters: the mass of the dark photon m(gamma)D and its mixing parameter with the photon, epsilon. The sensitivity of the SHiP detector is reviewed for dark photons in the mass range between 0.002 and 10 GeV. Different productionmechanisms are simulated, with the dark photons decaying to pairs of visible fermions, including both leptons and quarks. Exclusion contours are presented and compared with those of past experiments. The SHiP detector is expected to have a unique sensitivity for m. D ranging between 0.8 and 3.3(-0.5)(+0.2) GeV, and epsilon(2) ranging between 10(-11) and 10(-17).
  •  
13.
  • Ahdida, C., et al. (author)
  • Sensitivity of the SHiP experiment to Heavy Neutral Leptons
  • 2019
  • In: Journal of High Energy Physics (JHEP). - 1126-6708 .- 1029-8479. ; :4
  • Journal article (peer-reviewed)abstract
    • Heavy Neutral Leptons (HNLs) are hypothetical particles predicted by many extensions of the Standard Model. These particles can, among other things, explain the origin of neutrino masses, generate the observed matter-antimatter asymmetry in the Universe and provide a dark matter candidate. The SHiP experiment will be able to search for HNLs produced in decays of heavy mesons and travelling distances ranging between O(50 m) and tens of kilometers before decaying. We present the sensitivity of the SHiP experiment to a number of HNL's benchmark models and provide a way to calculate the SHiP's sensitivity to HNLs for arbitrary patterns of flavour mixings. The corresponding tools and data files are also made publicly available.
  •  
14.
  • Ahdida, C., et al. (author)
  • Sensitivity of the SHiP experiment to light dark matter
  • 2021
  • In: Journal of High Energy Physics (JHEP). - : Springer Nature. - 1126-6708 .- 1029-8479. ; :4
  • Journal article (peer-reviewed)abstract
    • Dark matter is a well-established theoretical addition to the Standard Model supported by many observations in modern astrophysics and cosmology. In this context, the existence of weakly interacting massive particles represents an appealing solution to the observed thermal relic in the Universe. Indeed, a large experimental campaign is ongoing for the detection of such particles in the sub-GeV mass range. Adopting the benchmark scenario for light dark matter particles produced in the decay of a dark photon, with αD = 0.1 and mA′ = 3mχ, we study the potential of the SHiP experiment to detect such elusive particles through its Scattering and Neutrino detector (SND). In its 5-years run, corresponding to 2 · 1020 protons on target from the CERN SPS, we find that SHiP will improve the current limits in the mass range for the dark matter from about 1 MeV to 300 MeV. In particular, we show that SHiP will probe the thermal target for Majorana candidates in most of this mass window and even reach the Pseudo-Dirac thermal relic.
  •  
15.
  • Ahdida, C., et al. (author)
  • The experimental facility for the Search for Hidden Particles at the CERN SPS
  • 2019
  • In: Journal of Instrumentation. - : Institute of Physics Publishing (IOPP). - 1748-0221. ; 14
  • Journal article (peer-reviewed)abstract
    • The Search for Hidden Particles (SHiP) Collaboration has shown that the CERN SPS accelerator with its 400 GeV/c proton beam offers a unique opportunity to explore the Hidden Sector [1-3]. The proposed experiment is an intensity frontier experiment which is capable of searching for hidden particles through both visible decays and through scattering signatures from recoil of electrons or nuclei. The high-intensity experimental facility developed by the SHiP Collaboration is based on a number of key features and developments which provide the possibility of probing a large part of the parameter space for a wide range of models with light long-lived super-weakly interacting particles with masses up to O(10) GeV/c(2) in an environment of extremely clean background conditions. This paper describes the proposal for the experimental facility together with the most important feasibility studies. The paper focuses on the challenging new ideas behind the beam extraction and beam delivery, the proton beam dump, and the suppression of beam-induced background.
  •  
16.
  • Ahdida, C., et al. (author)
  • The magnet of the scattering and neutrino detector for the SHiP experiment at CERN
  • 2020
  • In: Journal of Instrumentation. - 1748-0221. ; 15:01
  • Journal article (peer-reviewed)abstract
    • The Search for Hidden Particles (SHiP) experiment proposal at CERN demands a dedicated dipole magnet for its scattering and neutrino detector. This requires a very large volume to be uniformly magnetized at B > 1.2 T, with constraints regarding the inner instrumented volume as well as the external region, where no massive structures are allowed and only an extremely low stray field is admitted. In this paper we report the main technical challenges and the relevant design options providing a comprehensive design for the magnet of the SHiP Scattering and Neutrino Detector.
  •  
17.
  • Ahdida, C., et al. (author)
  • The SHiP experiment at the proposed CERN SPS Beam Dump Facility
  • 2022
  • In: European Physical Journal C. - : Springer Nature. - 1434-6044 .- 1434-6052. ; 82:5
  • Journal article (peer-reviewed)abstract
    • The Search for Hidden Particles (SHiP) Collaboration has proposed a general-purpose experimental facility operating in beam-dump mode at the CERN SPS accelerator to search for light, feebly interacting particles. In the baseline configuration, the SHiP experiment incorporates two complementary detectors. The upstream detector is designed for recoil signatures of light dark matter (LDM) scattering and for neutrino physics, in particular with tau neutrinos. It consists of a spectrometer magnet housing a layered detector system with high-density LDM/neutrino target plates, emulsion-film technology and electronic high-precision tracking. The total detector target mass amounts to about eight tonnes. The downstream detector system aims at measuring visible decays of feebly interacting particles to both fully reconstructed final states and to partially reconstructed final states with neutrinos, in a nearly background-free environment. The detector consists of a 50m\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm { \,m}$$\end{document} long decay volume under vacuum followed by a spectrometer and particle identification system with a rectangular acceptance of 5 m in width and 10 m in height. Using the high-intensity beam of 400GeV\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\,\mathrm {GeV}$$\end{document} protons, the experiment aims at profiting from the 4x1019\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$4\times 10<^>{19}$$\end{document} protons per year that are currently unexploited at the SPS, over a period of 5-10 years. This allows probing dark photons, dark scalars and pseudo-scalars, and heavy neutral leptons with GeV-scale masses in the direct searches at sensitivities that largely exceed those of existing and projected experiments. The sensitivity to light dark matter through scattering reaches well below the dark matter relic density limits in the range from a few MeV/c2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm {\,MeV\!/}c<^>2}$$\end{document} up to 100 MeV-scale masses, and it will be possible to study tau neutrino interactions with unprecedented statistics. This paper describes the SHiP experiment baseline setup and the detector systems, together with performance results from prototypes in test beams, as it was prepared for the 2020 Update of the European Strategy for Particle Physics. The expected detector performance from simulation is summarised at the end.
  •  
18.
  • Ahdida, C., et al. (author)
  • Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment
  • 2022
  • In: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 17:3
  • Journal article (peer-reviewed)abstract
    • In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved.
  •  
19.
  • Almqvist, PM, et al. (author)
  • Immunohistochemical detection of nestin in pediatric brain tumors
  • 2002
  • In: The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society. - : SAGE Publications. - 0022-1554. ; 50:2, s. 147-158
  • Journal article (peer-reviewed)abstract
    • Nestin is an intermediate filament protein (IFP) expressed in undifferentiated cells during CNS development and in CNS tumors. Previous studies have arrived at different conclusions in terms of which types of CNS tumors express nestin. In this report we establish an immunohistochemical protocol using antigen retrieval, which significantly enhances staining with two polyclonal anti-nestin antisera, #130 and #4350. The staining pattern was identical for the two nestin antisera and very similar to that of vimentin, while glial fibrillary acidic protein (GFAP), immunoreactivity was absent from 9.5-week-old forebrain. The current study of 20 primary CNS tumors from pediatric patients included seven ependymomas, seven primitive neuroectodermal tumors (PNETs), five pilocytic astrocytomas, and one glioblastoma multiforme (GBM). All these tumors expressed nestin to various extents, in contrast to five brain metastases tested. Strong nestin immunoreactivity was found in malignant primary CNS tumors, whereas benign pilocytic astrocytomas showed low but consistent nestin expression. In all tumors nestin immunoreactivity was confined to the cytoplasm of tumor cells and was co-expressed with astrocyte markers vimentin, GFAP, and S-100. Vascular endothelial cells of all neoplasms also showed marked immunoreactivity for nestin and vimentin, whereas they were negative for GFAP and S-100. In conclusion, antiserum #4350 detected nestin in formalin-fixed, paraffin-embedded tissue sections by heat-induced antigen retrieval immunohistochemistry. Nestin was expressed in both highly malignant and low malignant gliomas, indicating the potential use of nestin as a diagnostic tumor marker in surgical pathology.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  • Bergsten, U., et al. (author)
  • A randomized study comparing regular care with a nurse-led clinic based on tight disease activity control and person-centred care in patients with rheumatoid arthritis with moderate/high disease activity: A 6-month evaluation
  • 2019
  • In: Musculoskeletal Care. - : Wiley. - 1478-2189 .- 1557-0681. ; 17:3, s. 215-225
  • Journal article (peer-reviewed)abstract
    • Introduction: A recent survey showed that 27% of rheumatoid arthritis (RA) patients had inadequately controlled disease activity. Hence, there is a need for new strategies aiming at improving patient outcomes. The aim of the present study was to evaluate the effect of a nurse-led clinic with frequent visits, treat-to-target and person-centred care of patients with established RA and moderate-to-high disease activity compared with patients receiving regular care. Methods: The study was a randomized, controlled trial over 26weeks, with a nonrandomized extension to week 50. Patients were randomized to an intervention group (IG; nurse-led clinic) based on person-centred care, frequent visits and “treat to target”, or to a control group (CG) which visited the clinic according to care as usual. The primary outcome was the difference in the DAS28 change between the IG and the CG groups. Results: A total of 332 patients were screened for eligibility, of which 70 were randomly assigned to either the IG (n=36) or the CG (n=34) group. The primary outcome was not met, although patients in the IG group tended to improve more than those in the CG group (difference: 0.43 (95% confidence interval [CI] –0.27, 1.13). In both the IG and CG groups, delta-DAS28 improved significantly. The European League Against Rheumatology moderate or good response was achieved by 76% (95% CI 58, 89) in the IG and 49% (95% CI 32, 65) in the CG group. Conclusions: Disease activity tended to improve more with the nurse-led intervention compared with regular care, although the difference was not significant, probably partly due to the lack of statistical power. © 2019 The Authors Musculoskeletal Care published by John Wiley & Sons Ltd
  •  
25.
  • Brahe, C. H., et al. (author)
  • Retention and response rates in 14 261 PsA patients starting TNF inhibitor treatment-results from 12 countries in EuroSpA
  • 2020
  • In: Rheumatology. - : Oxford University Press (OUP). - 1462-0324 .- 1462-0332. ; 59:7, s. 1640-1650
  • Journal article (peer-reviewed)abstract
    • Objective. To investigate TNF inhibitor (TNFi) retention and response rates in European biologic-naive patients with PsA. Methods. Prospectively collected data on PsA patients in routine care from 12 European registries were pooled. Heterogeneity in baseline characteristics between registries were explored (analysis of variance and pairwise comparison). Retention rates (Kaplan-Meier), clinical remission [28-joint count DAS (DAS28) <2.6; 28 joint Disease Activity index for Psoriatic Arthritis 4] and ACR criteria for 20% improvement (ACR20)/ACR50/ACR70 were calculated, including LUNDEX adjustment. Results. Overall, 14 261 patients with PsA initiated a first TNFi. Considerable heterogeneity of baseline characteristics between registries was observed. The median 12-month retention rate (95% CI) was 77% (76, 78%), ranging from 68 to 90% across registries. Overall, DAS28/28 joint Disease Activity index for Psoriatic Arthritis remission rates at 6 months were 56%/27% (LUNDEX: 45%/22%). Six-month ACR20/50/70 responses were 53%/38%/22%, respectively. In patients initiating a first TNFi after 2009 with registered fulfilment of ClASsification for Psoriatic ARthritis (CASPAR) criteria (n = 1980) or registered one or more swollen joint at baseline (n = 5803), the retention rates and response rates were similar to those found overall. Conclusion. Approximately half of >14 000 patients with PsA who initiated first TNFi treatment in routine care were in DAS28 remission after 6 months, and three-quarters were still on the drug after 1 year. Considerable heterogeneity in baseline characteristics and outcomes across registries was observed. The feasibility of creating a large European database of PsA patients treated in routine care was demonstrated, offering unique opportunities for research with real-world data.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-25 of 97
Type of publication
journal article (68)
conference paper (26)
research review (2)
book chapter (1)
Type of content
peer-reviewed (64)
other academic/artistic (33)
Author/Editor
Treille, D. (14)
Dijkstra, H (14)
Jacobsson, R. (14)
Rovelli, T. (13)
Campanelli, M. (11)
De Roeck, A. (11)
show more...
Brenner, Richard (10)
Silverstein, Samuel ... (10)
Betancourt, C. (10)
Golubkov, D. (10)
Hakobyan, H. (10)
Lopes, L. (10)
Mermod, P. (10)
Vannucci, F. (10)
Xella, S. (10)
Milstead, David A. (10)
Breton, D. (10)
Kuznetsova, E. (10)
Wurm, M. (10)
Petridis, K. (10)
Gorbunov, S. (10)
Rademakers, A. (10)
Bondarenko, K. (10)
Kadenko, I. (10)
Korol, I. (10)
Montanari, A. (10)
Kovalenko, S. (10)
Sokolenko, A. (10)
Barker, G. J. (10)
Zaytsev, Yu (10)
Bogomilov, M. (10)
Tsenov, R. (10)
Aoki, S. (10)
Atkin, E. (10)
Khabibullin, M. (10)
Korzenev, A. (10)
Kudenko, Y. (10)
Mineev, O. (10)
Takahashi, S. (10)
Back, J.J. (10)
Nakano, T (10)
Fukuda, T. (10)
Vankova-Kirilova, G. (10)
Skorokhvatov, M. (10)
Calcaterra, A. (10)
Felici, G. (10)
Paoloni, A (10)
Golutvin, A (10)
Ratnikov, F (10)
Schmidt-Parzefall, W (10)
show less...
University
Karolinska Institutet (46)
Uppsala University (19)
University of Gothenburg (11)
Stockholm University (10)
Umeå University (9)
Royal Institute of Technology (8)
show more...
Lund University (8)
Chalmers University of Technology (5)
Luleå University of Technology (3)
Örebro University (3)
Linköping University (2)
Stockholm School of Economics (2)
Mid Sweden University (1)
Linnaeus University (1)
show less...
Language
English (95)
Swedish (1)
Spanish (1)
Research subject (UKÄ/SCB)
Natural sciences (21)
Medical and Health Sciences (20)
Engineering and Technology (6)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view