SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Kasprzak W. T.) "

Search: WFRF:(Kasprzak W. T.)

  • Result 1-8 of 8
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  • Jakosky, B. M., et al. (author)
  • The Mars Atmosphere and Volatile Evolution (MAVEN) Mission
  • 2015
  • In: Space Science Reviews. - : Springer Science and Business Media LLC. - 0038-6308 .- 1572-9672. ; 195:1-4, s. 3-48
  • Research review (peer-reviewed)abstract
    • The MAVEN spacecraft launched in November 2013, arrived at Mars in September 2014, and completed commissioning and began its one-Earth-year primary science mission in November 2014. The orbiter's science objectives are to explore the interactions of the Sun and the solar wind with the Mars magnetosphere and upper atmosphere, to determine the structure of the upper atmosphere and ionosphere and the processes controlling it, to determine the escape rates from the upper atmosphere to space at the present epoch, and to measure properties that allow us to extrapolate these escape rates into the past to determine the total loss of atmospheric gas to space through time. These results will allow us to determine the importance of loss to space in changing the Mars climate and atmosphere through time, thereby providing important boundary conditions on the history of the habitability of Mars. The MAVEN spacecraft contains eight science instruments (with nine sensors) that measure the energy and particle input from the Sun into the Mars upper atmosphere, the response of the upper atmosphere to that input, and the resulting escape of gas to space. In addition, it contains an Electra relay that will allow it to relay commands and data between spacecraft on the surface and Earth.
  •  
4.
  •  
5.
  •  
6.
  • Cui, J., et al. (author)
  • Diurnal variations of Titan's ionosphere
  • 2009
  • In: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 114:6, s. A06310-
  • Journal article (peer-reviewed)abstract
    • We present our analysis of the diurnal variations of Titan's ionosphere (between 1000 and 1300 km) based on a sample of Ion Neutral Mass Spectrometer (INMS) measurements in the Open Source Ion (OSI) mode obtained from eight close encounters of the Cassini spacecraft with Titan. Although there is an overall ion depletion well beyond the terminator, the ion content on Titan's nightside is still appreciable, with a density plateau of similar to 700 cm(-3) below similar to 1300 km. Such a plateau is a combined result of significant depletion of light ions and modest depletion of heavy ones on Titan's nightside. We propose that the distinctions between the diurnal variations of light and heavy ions are associated with their different chemical loss pathways, with the former primarily through "fast'' ion-neutral chemistry and the latter through "slow'' electron dissociative recombination. The strong correlation between the observed night-to-day ion density ratios and the associated ion lifetimes suggests a scenario in which the ions created on Titan's dayside may survive well to the nightside. The observed asymmetry between the dawn and dusk ion density profiles also supports such an interpretation. We construct a time-dependent ion chemistry model to investigate the effect of ion survival associated with solid body rotation alone as well as superrotating horizontal winds. For long-lived ions, the predicted diurnal variations have similar general characteristics to those observed. However, for short-lived ions, the model densities on the nightside are significantly lower than the observed values. This implies that electron precipitation from Saturn's magnetosphere may be an additional and important contributor to the densities of the short-lived ions observed on Titan's nightside.
  •  
7.
  • Esposito, B., et al. (author)
  • Progress of Design and Development for the ITER Radial Neutron Camera
  • 2022
  • In: Journal of fusion energy. - : Springer. - 0164-0313 .- 1572-9591. ; 41:2
  • Journal article (peer-reviewed)abstract
    • The paper presents an overview of the design status of the Radial Neutron Camera (RNC), that, together with the Vertical Neutron Camera, will provide, through reconstruction techniques applied to the measured line-integrated neutron fluxes, the time resolved measurement of the ITER neutron and alpha-source profile (i.e. neutron emissivity, neutrons emitted per unit time and volume). The RNC is composed of two subsystems, the In-Port RNC and Ex-Port RNC located, respectively, inside and outside the Plug of Equatorial Port #01. The In-Port subsystem is in a more advanced design stage since it has recently undergone the Final Design Review in the ITER procurement process. The paper describes the diagnostic layout, the interfaces, the measurement capabilities and the main challenges in its realization. Prototyping and testing of neutron detectors and electronics components were carried out and led to the choice of the component solutions that can match the environmental and operational constraints in terms radiation hardness, high temperature and electromagnetic compatibility. The performance of the RNC in terms of neutron emissivity measurement capability was assessed through 1D and 2D reconstruction analysis. It is proven that the neutron emissivity can be reconstructed in real-time within the measurement requirements: 10% accuracy, 10 ms time resolution and a/10 (a = plasma minor radius) space resolution.
  •  
8.
  • Olsson, Karl Wilhelm, 1985-, et al. (author)
  • Outcomes after endovascular aortic intervention in patients with connective tissue disease
  • 2023
  • In: JAMA Surgery. - : American Medical Association (AMA). - 2168-6254 .- 2168-6262. ; 158:8, s. 832-839
  • Journal article (peer-reviewed)abstract
    • Importance: Endovascular treatment is not recommended for aortic pathologies in patients with connective tissue diseases (CTDs) other than in redo operations and as bridging procedures in emergencies. However, recent developments in endovascular technology may challenge this dogma.Objective: To assess the midterm outcomes of endovascular aortic repair in patients with CTD.Design, Setting, and Participants: For this descriptive retrospective study, data on demographics, interventions, and short-term and midterm outcomes were collected from 18 aortic centers in Europe, Asia, North America, and New Zealand. Patients with CTD who had undergone endovascular aortic repair from 2005 to 2020 were included. Data were analyzed from December 2021 to November 2022.Exposure: All principal endovascular aortic repairs, including redo surgery and complex repairs of the aortic arch and visceral aorta.Main Outcomes and Measures: Short-term and midterm survival, rates of secondary procedures, and conversion to open repair.Results: In total, 171 patients were included: 142 with Marfan syndrome, 17 with Loeys-Dietz syndrome, and 12 with vascular Ehlers-Danlos syndrome (vEDS). Median (IQR) age was 49.9 years (37.9-59.0), and 107 patients (62.6%) were male. One hundred fifty-two (88.9%) were treated for aortic dissections and 19 (11.1%) for degenerative aneurysms. One hundred thirty-six patients (79.5%) had undergone open aortic surgery before the index endovascular repair. In 74 patients (43.3%), arch and/or visceral branches were included in the repair. Primary technical success was achieved in 168 patients (98.2%), and 30-day mortality was 2.9% (5 patients). Survival at 1 and 5 years was 96.2% and 80.6% for Marfan syndrome, 93.8% and 85.2% for Loeys-Dietz syndrome, and 75.0% and 43.8% for vEDS, respectively. After a median (IQR) follow-up of 4.7 years (1.9-9.2), 91 patients (53.2%) had undergone secondary procedures, of which 14 (8.2%) were open conversions.Conclusions and Relevance: This study found that endovascular aortic interventions, including redo procedures and complex repairs of the aortic arch and visceral aorta, in patients with CTD had a high rate of early technical success, low perioperative mortality, and a midterm survival rate comparable with reports of open aortic surgery in patients with CTD. The rate of secondary procedures was high, but few patients required conversion to open repair. Improvements in devices and techniques, as well as ongoing follow-up, may result in endovascular treatment for patients with CTD being included in guideline recommendations.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-8 of 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view