SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Laanmets Peep) "

Search: WFRF:(Laanmets Peep)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Frigoli, Enrico, et al. (author)
  • Design and rationale of the Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Standard DAPT Regimen (MASTER DAPT) Study
  • 2019
  • In: American Heart Journal. - : MOSBY-ELSEVIER. - 0002-8703 .- 1097-6744. ; 209, s. 97-105
  • Journal article (peer-reviewed)abstract
    • Background The optimal duration of antiplatelet therapy in high-bleeding risk (HBR) patients with coronary artery disease treated with newer-generation drug-eluting bioresorbable polymer-coated stents remains unclear. Design MASTER DAPT (clinicaltrial.gov NCT03023020) is an investigator-initiated, open-label, multicenter, randomized controlled trial comparing an abbreviated versus a standard duration of antiplatelet therapy after bioresorbable polymer-coated Ultimaster (TANSEI) sirolimus-eluting stent implantation in approximately 4,300 HBR patients recruited from >= 100 interventional cardiology centers globally. After a mandatory 30-day dual-antiplatelet therapy (DAPT) run-in phase, patients are randomized to (a) a single antiplatelet regimen until study completion or up to 5 months in patients with clinically indicated oral anticoagulation (experimental 1-month DAPT group) or (b) continue DAPT for at least 5 months in patients without or 2 in patients with concomitant indication to oral anticoagulation, followed by a single antiplatelet regimen (standard antipkitelet regimen). With a final sample size of 4,300 patients, this study is powered to assess the noninferiority of the abbreviated antiplatelet regimen with respect to the net adverse clinical and major adverse cardiac and cerebral events composite end points and if satisfied for the superiority of abbreviated as compared to standard antiplatelet therapy duration in terms of major or clinically relevant nonmajor bleeding. Study end points will be adjudicated by a blinded Clinical Events Committee. Conclusions The MASTER DAPT study is the first randomized controlled trial aiming at ascertaining the optimal duration of antiplatelet therapy in HBR patients treated with sirolimus-eluting bioresorbable polymer-coated stent implantation.
  •  
2.
  • Holm, Niels R, et al. (author)
  • OCT or Angiography Guidance for PCI in Complex Bifurcation Lesions.
  • 2023
  • In: The New England journal of medicine. - 1533-4406. ; 389:16, s. 1477-1487
  • Journal article (peer-reviewed)abstract
    • Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain.We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years.We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P=0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group.Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).
  •  
3.
  • Noc, Marko, et al. (author)
  • A multicentre, prospective, randomised controlled trial to assess the safety and effectiveness of cooling as an adjunctive therapy to percutaneous intervention in patients with acute myocardial infarction : The COOL AMI EU Pivotal Trial
  • 2021
  • In: EuroIntervention. - 1774-024X. ; 17:6, s. 466-473
  • Journal article (peer-reviewed)abstract
    • Background: Despite primary PCI (PPCI), ST-elevation myocardial infarction (STEMI) can still result in large infarct size (IS). New technology with rapid intravascular cooling showed positive signals for reduction in IS in anterior STEMI. Aims: We investigated the effectiveness and safety of rapid systemic intravascular hypothermia as an adjunct to PPCI in conscious patients, with anterior STEMI, without cardiac arrest. Methods: Hypothermia was induced using the ZOLL® Proteus™ intravascular cooling system. After randomisation of 111 patients, 58 to hypothermia and 53 to control groups, the study was prematurely discontinued by the sponsor due to inconsistent patient logistics between the groups resulting in significantly longer total ischaemic delay in the hypothermia group (232 vs 188 minutes; p<0.001). Results: There were no differences in angiographic features and PPCI result between the groups. Intravascular temperature at wire crossing was 33.3+0.9°C. Infarct size/left ventricular (IS/LV) mass by cardiac magnetic resonance (CMR) at day 4-6 was 21.3% in the hypothermia group and 20.0% in the control group (p=0.540). Major adverse cardiac events at 30 days increased non-significantly in the hypothermia group (8.6% vs 1.9%; p=0.117) while cardiogenic shock (10.3% vs 0%; p=0.028) and paroxysmal atrial fibrillation (43.1% vs 3.8%; p<0.001) were significantly more frequent in the hypothermia group. Conclusions: The ZOLL Proteus intravascular cooling system reduced temperature to 33.3°C before PPCI in patients with anterior STEMI. Due to inconsistent patient logistics between the groups, this hypothermia protocol resulted in a longer ischaemic delay, did not reduce IS/LV mass and was associated with increased adverse events.
  •  
4.
  • Noc, Marko, et al. (author)
  • COOL AMI EU pilot trial : A multicentre, prospective, randomised controlled trial to assess cooling as an adjunctive therapy to percutaneous intervention in patients with acute myocardial infarction
  • 2017
  • In: EuroIntervention. - 1774-024X. ; 13:5, s. 531-539
  • Journal article (peer-reviewed)abstract
    • Aims: We aimed to investigate the rapid induction of therapeutic hypothermia using the ZOLL Proteus Intravascular Temperature Management System in patients with anterior ST-elevation myocardial infarction (STEMI) without cardiac arrest. Methods and results: A total of 50 patients were randomised; 22 patients (88%; 95% confidence interval [CI]: 69-97%) in the hypothermia group and 23 patients (92%; 95% CI: 74-99) in the control group completed cardiac magnetic resonance imaging at four to six days and 30-day follow-up. Intravascular temperature at coronary guidewire crossing after 20.5 minutes of endovascular cooling decreased to 33.6°C (range 31.9-35.5°C). There was a 17-minute (95% CI: 4.6-29.8 min) cooling-related delay to reperfusion. In "per protocol" analysis, median infarct size/left ventricular mass was 16.7% in the hypothermia group versus 23.8% in the control group (absolute reduction 7.1%, relative reduction 30%; p=0.31) and median left ventricular ejection fraction (LVEF) was 42% in the hypothermia group and 40% in the control group (absolute reduction 2.4%, relative reduction 6%; p=0.36). Except for self-terminating paroxysmal atrial fibrillation (32% versus 8%; p=0.074), there was no excess of adverse events in the hypothermia group. Conclusions: We rapidly and safely cooled patients with anterior STEMI to 33.6°C at the time of coronary guidewire crossing. This is ≥1.1°C lower than in previous cooling studies. Except for self-terminating atrial fibrillation, there was no excess of adverse events and no clinically important cooling-related delay to reperfusion. A statistically non-significant numerical 7.1% absolute and 30% relative reduction in infarct size warrants a pivotal trial powered for efficacy.
  •  
5.
  • van Veelen, Anna, et al. (author)
  • Recovery of right ventricular function and strain in patients with ST-segment elevation myocardial infarction and concurrent chronic total occlusion.
  • 2022
  • In: The international journal of cardiovascular imaging. - 1875-8312. ; 38:3, s. 631-641
  • Journal article (peer-reviewed)abstract
    • The right ventricle (RV) is frequently involved in ST-segment elevation myocardial infarction (STEMI) when the culprit or concurrent chronic total occlusion (CTO) is located in the right coronary artery (RCA). We investigated RV function recovery in STEMI-patients with concurrent CTO. In EXPLORE, STEMI-patients with concurrent CTO were randomized to CTO percutaneous coronary intervention (PCI) or no CTO-PCI. We analyzed 174 EXPLORE patients with serial cardiovascular magnetic resonance imaging RV data (baseline and 4-month follow-up), divided into three groups: CTO-RCA (CTO in RCA, culprit in non-RCA; n = 89), IRA-RCA (infarct related artery [IRA] in RCA, CTO in non-RCA; n = 56), and no-RCA (culprit and CTO not in RCA; n = 29). Tricuspid annular plane systolic excursion (TAPSE), RV ejection fraction (RVEF), RV global longitudinal strain (GLS) and free wall longitudinal strain (FWLS) were measured. We found that RV strain and TAPSE improved in IRA-RCA and CTO-RCA (irrespective of CTO-PCI) at follow-up, but not in no-RCA. Only RV FWLS was different among groups at baseline, which was lower in IRA-RCA than no-RCA (- 26.0 ± 8.3% versus - 31.0 ± 6.4%, p = 0.006). Baseline RVEF, RV end-diastolic volume and TAPSE were associated with RVEF at 4 months. RV function parameters were not predictive of 4 year mortality, although RV GLS showed additional predictive value for New York Heart Association Classification > 1 at 4 months. In conclusion, RV parameters significantly improved in patients with acute or chronic RCA occlusion, but not in no-RCA patients. RV FWLS was the only RV parameter able to discriminate between acute ischemic and non-ischemic myocardium. Moreover, RV GLS was independently predictive for functional status.
  •  
6.
  • Vlieger, Selina, et al. (author)
  • One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent : a propensity-matched analysis of two international all-comers registries
  • 2021
  • In: Coronary Artery Disease. - : Lippincott Williams & Wilkins. - 0954-6928 .- 1473-5830. ; 32:5, s. 391-396
  • Journal article (peer-reviewed)abstract
    • OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view