SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ryd G) "

Sökning: WFRF:(Ryd G)

  • Resultat 1-11 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aad, G, et al. (författare)
  • 2015
  • swepub:Mat__t
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Fricke, Katrin, et al. (författare)
  • Fetal cardiac magnetic resonance imaging of the descending aorta in suspected left-sided cardiac obstructions
  • 2023
  • Ingår i: Frontiers in Cardiovascular Medicine. - 2297-055X. ; 10, s. 01-10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Severe left-sided cardiac obstructions are associated with high morbidity and mortality if not detected in time. The correct prenatal diagnosis of coarctation of the aorta (CoA) is difficult. Fetal cardiac magnetic resonance imaging (CMR) may improve the prenatal diagnosis of complex congenital heart defects. Flow measurements in the ascending aorta could aid in predicting postnatal CoA, but its accurate visualization is challenging.Objectives: To compare the flow in the descending aorta (DAo) and umbilical vein (UV) in fetuses with suspected left-sided cardiac obstructions with and without the need for postnatal intervention and healthy controls by fetal phase-contrast CMR flow. A second objective was to determine if adding fetal CMR to echocardiography (echo) improves the fetal CoA diagnosis.Methods: Prospective fetal CMR phase-contrast flow in the DAo and UV and echo studies were conducted between 2017 and 2022.Results: A total of 46 fetuses with suspected left-sided cardiac obstructions [11 hypoplastic left heart syndrome (HLHS), five critical aortic stenosis (cAS), and 30 CoA] and five controls were included. Neonatal interventions for left-sided cardiac obstructions (n = 23) or comfort care (n = 1 with HLHS) were pursued in all 16 fetuses with suspected HLHS or cAS and in eight (27%) fetuses with true CoA. DAo or UV flow was not different in fetuses with and without need of intervention. However, DAo and UV flows were lower in fetuses with either retrograde isthmic systolic flow [DAo flow 253 (72) vs. 261 (97) ml/kg/min, p = 0.035; UV flow 113 (75) vs. 161 (81) ml/kg/min, p = 0.04] or with suspected CoA and restrictive atrial septum [DAo flow 200 (71) vs. 268 (94) ml/kg/min, p = 0.04; UV flow 89 vs. 159 (76) ml/kg/min, p = 0.04] as well as in those without these changes. Adding fetal CMR to fetal echo predictors for postnatal CoA did not improve the diagnosis of CoA.Conclusion: Fetal CMR-derived DAo and UV flow measurements do not improve the prenatal diagnosis of left-sided cardiac obstructions, but they could be important in identifying fetuses with a more severe decrease in blood flow across the left side of the heart. The physiological explanation may be a markedly decreased left ventricular cardiac output with subsequent retrograde systolic isthmic flow and decreased total DAo flow.
  •  
10.
  • Hansson, Ulrik, et al. (författare)
  • Histologic reactions to particulate wear debris in different mesenchymal tissues : Studies on the nonreplaced compartment from revised uni-knees
  • 2004
  • Ingår i: The Journal of Arthroplasty. - : Elsevier BV. - 0883-5403 .- 1532-8406. ; 19:4, s. 481-487
  • Tidskriftsartikel (refereegranskat)abstract
    • The interface between bone and artificial-joint implants consists of soft tissue. This tissue varies from fibrocartilage to loose fibrous tissue. Tissues that resemble those can be found in normal joints. Sixteen knees with unicompartmental knee prostheses, revised because of excessive wear of the tibial insert, were studied. Synovium, synovial fluid, cartilage, and bone from the nonreplaced compartment were studied with light microscopy. We found wear particles and reactions to those in all tissues except cartilage. In the subchondral bone, we found osteolytic-like processes undermining the cartilage peripherally. Our conclusion from these findings is that the histologic composition of the bone-implant interface might be an important factor regarding the reaction of the tissue to wear particles and, thus, component fixation. © 2004 Elsevier Inc. All rights reserved.
  •  
11.
  • Nilsson, Kjell G., 1953- (författare)
  • Kinematics and fixation of total knee arthroplasties : a clinical, radiographic, scintimetric, and roentgen stereophotogrammetric evaluation
  • 1992
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Aseptic loosening of the tibial component is an important cause of failure after total knee arthroplasty. Bone destruction often claimed to be caused by the cement makes the revision difficult. In order to treat younger patients, uncemented fixation has been introduced, but the etiology to loosening is multifactorial and only partly known. Early detection of implant migration facilitates research in this field but is difficult using conventional techniques. In this study modified versions of roentgen stereophotogrammetric analysis (RSA) were developed to obtain accurate and standardized evaluations facilitating comparison between prosthetic designs. The method was used to record the efficacy of cemented and uncemented fixation of different designs of the tibial component, to determine the accuracy of scintimetry in the detection of early aseptic loosening, and to analyse the in vivo kinematics of knee arthroplasties with different design and stability between the joint surfaces.Forty-three arthroplasties with comparatively high inherent stability of the joint surfaces were randomized to cemented or uncemented fixation of the tibial component. In all groups micromovements were rather large, but with no differences between the cemented and uncemented components. The preoperative diagnosis (arthrosis OA, n=25; rheumatoid arthritis RA, n=18) did not influence the magnitude of micromotion.20 arthroplasties with the same design as above but equipped with an intramedullary stem, were randomized to cemented or uncemented fixation in patients with RA. Cement improved the fixation. Uncemented stemmed components displayed micromovements seemingly larger than unstemmed ones.34 arthroplasties with an unconstrained design of the joint area and fixed to the tibia with four pegs were randomized to cemented or uncemented fixation in patients with OA. When used uncemented 4 screws were added. Compared with previously investigated designs small micromotions were recorded, and especially in the cemented cases. Uncemented components with thin polyethylene inserts displayed larger initial micromotions. The preoperative deformity influenced the direction of the micromotion.33 knees were followed prospectively with RSA and scintimetry to evaluate any correlation between these methods. Low activity under the tibial component at 2 years implied prosthetic stability, whereas high activity indicated instability or high bone remodelling caused by the preoperative malalignment.The in vivo kinematics in three different designs of knee arthroplasties were analyzed during active flexion and extension without weight-bearing. Each type of prosthesis displayed design-specific abnormalities when compared with a normal material. Pronounced posterior tibial translations were recorded during flexion regardless whether the posterior cruciate ligament had been sacrificed or not. Data from the kinematic and the fixation studies suggest that movements restricted by the design of the joint area are transmitted to the bony interface with design-specific micromotions as the result.Analysis of knee joint kinematics during extension and weight-bearing revealed small alterations compared with non-weight-bearing. Evaluation of the three-dimensional movements in terms of helical axis rotations and translations confirmed the constrained or unconstrained in vivo behaviour of the designs under study. This analysis also facilitated the interpretation of the kinematic behaviour of the prosthetic knees and may be of value in the evaluation of new designs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-11 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy