1. |
- Bernigaud, Virgile, et al.
(author)
-
Electron capture-induced dissociation of AK dipeptide dications : Influence of ion velocity, crown-ether complexation and collision gas
- 2008
-
In: International Journal of Mass Spectrometry. - : Elsevier BV. - 1387-3806 .- 1873-2798. ; 276:2-3, s. 77-81
-
Journal article (peer-reviewed)abstract
- The fragmentation of doubly protonated AK dipeptide ions has been investigated after collisional electron transfer. Electron capture leads to three dominant channels, H loss, NH3 loss, and N–Cα bond breakage to give either c+ or z+ fragment ions. The relative importance of these channels has been explored as a function of ion velocity, the degree of complexation with crown ether, and collision gas. Our results indicate that H loss and NH3 loss are competing channels whereas the probability of N–Cα bond breakage is more or less constant.
|
|
2. |
- Colvill, Emma, et al.
(author)
-
A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy : A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking
- 2016
-
In: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140. ; 119:1, s. 159-165
-
Journal article (peer-reviewed)abstract
- Purpose A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion. Methods and materials Ten institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded. Results For all lung traces all measurement sets show improved dose accuracy with a mean 2%/2 mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p < 0.001). For all prostate the mean 2%/2 mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p < 0.001). The difference between the four systems was small with an average 2%/2 mm γ-fail rate of <3% for all systems with adaptation for lung and prostate. Conclusions The investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods.
|
|