SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Bütikofer L.) "

Search: WFRF:(Bütikofer L.)

  • Result 1-12 of 12
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Aalbers, J., et al. (author)
  • DARWIN : towards the ultimate dark matter detector
  • 2016
  • In: Journal of Cosmology and Astroparticle Physics. - : IOP Publishing. - 1475-7516. ; :11
  • Journal article (peer-reviewed)abstract
    • DARk matter WImp search with liquid xenoN (DARWIN(2)) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c(2), such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions,galactic axion-like particles and the neutrinoless double-beta decay of Xe-136, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
  •  
3.
  • Aprile, E., et al. (author)
  • Online Rn-222 removal by cryogenic distillation in the XENON100 experiment
  • 2017
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 77:6
  • Journal article (peer-reviewed)abstract
    • We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant Rn-222 background originating from radon emanation. After inserting an auxiliary 222Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the Rn-222 activity concentration inside the XENON100 detector.
  •  
4.
  • Aprile, E., et al. (author)
  • Removing krypton from xenon by cryogenic distillation to the ppq level
  • 2017
  • In: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 77:5
  • Journal article (peer-reviewed)abstract
    • The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the beta-emitter Kr-85 which is present in the xenon. For XENON1T a concentration of natural krypton in xenon Kr-nat/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10(-15) mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 . 10(5) with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of natKr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
  •  
5.
  • Aprile, E., et al. (author)
  • Results from a calibration of XENON100 using a source of dissolved radon-220
  • 2017
  • In: Physical Review D. - 2470-0010 .- 2470-0029. ; 95:7
  • Journal article (peer-reviewed)abstract
    • A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220-Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t(1/2) = (293.9 +/- (1.0)(stat) +/- (0.6)(sys)) ns.
  •  
6.
  • Aprile, E., et al. (author)
  • Signal yields of keV electronic recoils and their discrimination from nuclear recoils in liquid xenon
  • 2018
  • In: Physical Review D. - 2470-0010 .- 2470-0029. ; 97:9
  • Journal article (peer-reviewed)abstract
    • We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence on the drift field and photon detection efficiency are investigated at these low energies. The results provide new measurements in the energy region of interest for dark matter searches using liquid xenon.
  •  
7.
  • Aprile, E., et al. (author)
  • Low-mass dark matter search using ionization signals in XENON100
  • 2016
  • In: Physical Review D. - 2470-0010. ; 94:9
  • Journal article (peer-reviewed)abstract
    • We perform a low-mass dark matter search using an exposure of 30 kg x yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7 keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7 keV to 9.1 keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6 GeV/c(2) above 1.4 x 10(-41) cm(2) at 90% confidence level.
  •  
8.
  • Aprile, E., et al. (author)
  • Physics reach of the XENON1T dark matter experiment
  • 2016
  • In: Journal of Cosmology and Astroparticle Physics. - : IOP Publishing. - 1475-7516. ; :4
  • Journal article (peer-reviewed)abstract
    • The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80+/-0.15) . 10(-4) (kg.day.keV)(-1), mainly due to the decay of Rn-222 daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 +/- 0.1) (t.y)(-1) from radiogenic neutrons, (1.8+/-0.3) . 10(-2) (t.y)(-1) from coherent scattering of neutrinos, and less than 0.01 (t.y)(-1) from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Pro file Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency L-eff, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 tonne fiducial volume, the sensitivity reaches a minimum cross section of 1.6 . 10(-47) cm(2) at m(chi) = 50 GeV/c(2).
  •  
9.
  • Aprile, E., et al. (author)
  • Search for two-neutrino double electron capture of Xe-124 with XENON100
  • 2017
  • In: Physical Review C. - 2469-9985. ; 95:2
  • Journal article (peer-reviewed)abstract
    • Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For Xe-124 this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K shell of 124Xe using 7636 kg d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90% credibility limit on the half-life T-1/2 > 6.5 x 10(20) yr. We have also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and found a sensitivity of T-1/2 > 6.1 x 10(22) yr after an exposure of 2 t yr.
  •  
10.
  • Aprile, E., et al. (author)
  • XENON100 dark matter results from a combination of 477 live days
  • 2016
  • In: Physical Review D. - 2470-0010 .- 2470-0029. ; 94:12
  • Journal article (peer-reviewed)abstract
    • We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultralow electromagnetic background of the experiment, similar to 5 x 10(-3) events/(keV(ee) x kg x day)) before electronic recoil rejection, together with the increased exposure of 48 kg x yr, improves the sensitivity. A profile likelihood analysis using an energy range of (6.6-43.3) keV(nr) sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c(2), with a minimum of 1.1 x 10(-45) cm(2) at 50 GeV/c(2) and 90% confidence level. We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 x 10(-40) cm(2) (52 x 10(-40) cm(2)) at a WIMP mass of 50 GeV/c(2), at 90% confidence level.
  •  
11.
  • Shameer, S., et al. (author)
  • TrypanoCyc: a community-led biochemical pathways database for Trypanosoma brucei
  • 2015
  • In: Nucleic Acids Research. - : Oxford University Press (OUP). - 0305-1048 .- 1362-4962. ; 43:D1, s. D637-D644
  • Journal article (peer-reviewed)abstract
    • The metabolic network of a cell represents thecatabolic and anabolic reactions that interconvertsmall molecules (metabolites) through the activity ofenzymes, transporters and non-catalyzed chemicalreactions. Our understanding of individual metabolicnetworks is increasing as we learn more aboutthe enzymes that are active in particular cells underparticular conditions and as technologies advanceto allow detailed measurements of the cellularmetabolome. Metabolic network databases areof increasing importance in allowing us to contextualisedata sets emerging from transcriptomic,proteomic and metabolomic experiments. Here wepresent a dynamic database, TrypanoCyc (http://www.metexplore.fr/trypanocyc/), which describesthe generic and condition-specific metabolic networkof Trypanosoma brucei, a parasitic protozoan responsiblefor human and animal African trypanosomiasis.In addition to enabling navigation through the BioCyc-based TrypanoCyc interface, we have alsoimplemented a network-based representation of theinformation through MetExplore, yielding a novel environmentin which to visualise the metabolism ofthis important parasite.
  •  
12.
  • Altincekic, Nadide, et al. (author)
  • Targeting the Main Protease (Mpro, nsp5) by Growth of Fragment Scaffolds Exploiting Structure-Based Methodologies
  • 2024
  • In: ACS Chemical Biology. - : American Chemical Society (ACS). - 1554-8929 .- 1554-8937. ; 19:2, s. 563-574
  • Journal article (peer-reviewed)abstract
    • The main protease Mpro, nsp5, of SARS-CoV-2 (SCoV2) is one of its most attractive drug targets. Here, we report primary screening data using nuclear magnetic resonance spectroscopy (NMR) of four different libraries and detailed follow-up synthesis on the promising uracil-containing fragment Z604 derived from these libraries. Z604 shows time-dependent binding. Its inhibitory effect is sensitive to reducing conditions. Starting with Z604, we synthesized and characterized 13 compounds designed by fragment growth strategies. Each compound was characterized by NMR and/or activity assays to investigate their interaction with Mpro. These investigations resulted in the four-armed compound 35b that binds directly to Mpro. 35b could be cocrystallized with Mpro revealing its noncovalent binding mode, which fills all four active site subpockets. Herein, we describe the NMR-derived fragment-to-hit pipeline and its application for the development of promising starting points for inhibitors of the main protease of SCoV2.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-12 of 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view