SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Eriksson Boija Elisabet) "

Search: WFRF:(Eriksson Boija Elisabet)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Eichenlaub, Manuel, et al. (author)
  • Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems
  • 2024
  • In: Diabetes Technology & Therapeutics. - : Mary Ann Liebert. - 1520-9156 .- 1557-8593. ; 26:4, s. 263-275
  • Journal article (peer-reviewed)abstract
    • Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC), that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels is suggested that enables the collection of comparator data with these characteristics. This work is an important step towards establishing a future standard for the performance evaluation of CGM systems.
  •  
2.
  • Freckmann, Guido, et al. (author)
  • Clinical Performance Evaluation of Continuous Glucose Monitoring Systems : A Scoping Review and Recommendations for Reporting
  • 2023
  • In: Journal of Diabetes Science and Technology. - : Sage Publications. - 1932-2968. ; 17:6, s. 1506-1526
  • Research review (peer-reviewed)abstract
    • The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
  •  
3.
  • Helmersson, Johanna, et al. (author)
  • Lower creatinine concentration values and lower inter-laboratory variation among Swedish hospital laboratories in 2014 compared to 1996 : results from the Equalis external quality assessment program
  • 2019
  • In: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 57:6, s. 838-844
  • Journal article (peer-reviewed)abstract
    • Background:Creatinine measurement for estimation of glomerular filtration rate (GFR) is a frequently used laboratory test. Differences in analytic creatinine methods have caused large inter-laboratory variation. International and national standardization efforts have been made in the last decade.Methods:This study describes the results of the standardization efforts in Sweden by summarizing data for creatinine concentration in blood plasma in the Equalis quality assessment program during 1996-2014.Results:Non-compensated Jaffe methods dominated in 1996-2001 (91 of 103 laboratories; 90%) and were then gradually replaced by either compensated Jaffe methods or enzymatic creatinine methods. In 2014 a majority of Swedish hospital laboratories (139 of 159; 87%) used enzymatic methods. The reported mean creatinine value by the Swedish laboratories was about 10 mu mol/L higher than the isotope dilution mass spectrometry (IDMS) assured reference value in 2003, but consistent with the reference value from 2009 to 2014. The inter-laboratory CV was 7%-9% for creatinine values until 2007, and thereafter gradually decreased to about 4%-5% in 2014.Conclusions:The introduction of enzymatic methods in Swedish laboratories has contributed to achieving a low inter-laboratory variation. Also, the reported values are lower for enzymatic methods compared to Jaffe methods, and the values obtained with enzymatic methods were consistent with IDMS certified values established at reference laboratories. Thus, many Swedish hospital laboratories reported 10 mu mol/L lower, and more true, creatinine concentrations in 2012 than in 2003, which may cause bias in longitudinal studies.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view