SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Horvat S) "

Search: WFRF:(Horvat S)

  • Result 1-50 of 63
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Aad, G., et al. (author)
  • 2010
  • swepub:Mat__t
  •  
2.
  • Aad, G., et al. (author)
  • 2010
  • swepub:Mat__t
  •  
3.
  • Aad, G., et al. (author)
  • 2010
  • swepub:Mat__t
  •  
4.
  •  
5.
  •  
6.
  • Aad, G., et al. (author)
  • The ATLAS Simulation Infrastructure
  • 2010
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 70:3, s. 823-874
  • Journal article (peer-reviewed)abstract
    • The simulation software for the ATLAS Experiment at the Large Hadron Collider is being used for large-scale production of events on the LHC Computing Grid. This simulation requires many components, from the generators that simulate particle collisions, through packages simulating the response of the various detectors and triggers. All of these components come together under the ATLAS simulation infrastructure. In this paper, that infrastructure is discussed, including that supporting the detector description, interfacing the event generation, and combining the GEANT4 simulation of the response of the individual detectors. Also described are the tools allowing the software validation, performance testing, and the validation of the simulated output against known physics processes.
  •  
7.
  • Aad, G., et al. (author)
  • Readiness of the ATLAS Tile Calorimeter for LHC collisions
  • 2010
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 70:4, s. 1193-1236
  • Journal article (peer-reviewed)abstract
    • The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector has successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration systems are presented, as well as the validation of the timing and energy calibration carried out with minimum ionising cosmic ray muons data. The calibration systems' precision is well below the design value of 1%. The determination of the global energy scale was performed with an uncertainty of 4%.
  •  
8.
  • Aad, G., et al. (author)
  • The ATLAS Inner Detector commissioning and calibration
  • 2010
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 70:3, s. 787-821
  • Journal article (peer-reviewed)abstract
    • The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1 +/- 0.9 mu m and a relative momentum resolution sigma (p) /p=(4.83 +/- 0.16)x10(-4) GeV(-1)xp (T) have been measured for high momentum tracks.
  •  
9.
  • Aad, G., et al. (author)
  • Commissioning of the ATLAS Muon Spectrometer with cosmic rays
  • 2010
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 70:3, s. 875-916
  • Journal article (peer-reviewed)abstract
    • The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking chambers, their alignment, the detector control system, the data acquisition and the analysis programs. We present the performance in the relevant parameters that determine the quality of the muon measurement. We discuss the single element efficiency, resolution and noise rates, the calibration method of the detector response and of the alignment system, the track reconstruction efficiency and the momentum measurement. The results show that the detector is close to the design performance and that the Muon Spectrometer is ready to detect muons produced in high energy proton-proton collisions.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  • Kondo, Y., et al. (author)
  • First observation of 28 O
  • 2023
  • In: Nature. - 0028-0836 .- 1476-4687. ; 620:7976, s. 965-970
  • Journal article (peer-reviewed)abstract
    • Subjecting a physical system to extreme conditions is one of the means often used to obtain a better understanding and deeper insight into its organization and structure. In the case of the atomic nucleus, one such approach is to investigate isotopes that have very different neutron-to-proton (N/Z) ratios than in stable nuclei. Light, neutron-rich isotopes exhibit the most asymmetric N/Z ratios and those lying beyond the limits of binding, which undergo spontaneous neutron emission and exist only as very short-lived resonances (about 10−21s), provide the most stringent tests of modern nuclear-structure theories. Here we report on the first observation of 28O and 27O through their decay into 24O and four and three neutrons, respectively. The 28O nucleus is of particular interest as, with the Z = 8 and N = 20 magic numbers1,2, it is expected in the standard shell-model picture of nuclear structure to be one of a relatively small number of so-called ‘doubly magic’ nuclei. Both 27O and 28O were found to exist as narrow, low-lying resonances and their decay energies are compared here to the results of sophisticated theoretical modelling, including a large-scale shell-model calculation and a newly developed statistical approach. In both cases, the underlying nuclear interactions were derived from effective field theories of quantum chromodynamics. Finally, it is shown that the cross-section for the production of 28O from a 29F beam is consistent with it not exhibiting a closed N = 20 shell structure.
  •  
14.
  • Lihtar, I., et al. (author)
  • RELATIVISTIC COULOMB EXCITATION OF 124 Sn
  • 2024
  • In: Acta Physica Polonica B, Proceedings Supplement. - 1899-2358. ; 17:3
  • Journal article (peer-reviewed)abstract
    • The Coulomb excitation of 124, 128, 130, 132, 134Sn isotopes in the electric field of a Pb target have been studied using the R3B setup as a part of the FAIR Phase-0 program. The experiment was motivated by the possibility of using the nuclear dipole response to infer valuable information on the slope of the symmetry energy of the nuclear equation of state. Measurements were performed in inverse kinematics at relativistic energies of 750 MeV/u and 904 MeV/u. The analysis method and preliminary results for the decay channel with a single outgoing neutron for 124Sn are reported.
  •  
15.
  • Wang, H., et al. (author)
  • Intruder configurations in 29 Ne at the transition into the island of inversion: Detailed structure study of 28 Ne
  • 2023
  • In: Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics. - 0370-2693. ; 843
  • Journal article (peer-reviewed)abstract
    • Detailed γ-ray spectroscopy of the exotic neon isotope 28Ne has been performed for the first time using the one-neutron removal reaction from 29Ne on a liquid hydrogen target at 240 MeV/nucleon. Based on an analysis of parallel momentum distributions, a level scheme with spin-parity assignments has been constructed for 28Ne and the negative-parity states are identified for the first time. The measured partial cross sections and momentum distributions reveal a significant intruder p-wave strength providing evidence of the breakdown of the N=20 and N=28 shell gaps. Only a weak, possible f-wave strength was observed to bound final states. Large-scale shell-model calculations with different effective interactions do not reproduce the large p-wave and small f-wave strength observed experimentally, indicating an ongoing challenge for a complete theoretical description of the transition into the island of inversion along the Ne isotopic chain.
  •  
16.
  • Boretzky, K., et al. (author)
  • NeuLAND: The high-resolution neutron time-of-flight spectrometer for R 3 B at FAIR
  • 2021
  • In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1014
  • Journal article (peer-reviewed)abstract
    • NeuLAND (New Large-Area Neutron Detector) is the next-generation neutron detector for the R3B (Reactions with Relativistic Radioactive Beams) experiment at FAIR (Facility for Antiproton and Ion Research). NeuLAND detects neutrons with energies from 100 to 1000 MeV, featuring a high detection efficiency, a high spatial and time resolution, and a large multi-neutron reconstruction efficiency. This is achieved by a highly granular design of organic scintillators: 3000 individual submodules with a size of 5 × 5 × 250 cm3 are arranged in 30 double planes with 100 submodules each, providing an active area of 250 × 250 cm2 and a total depth of 3 m. The spatial resolution due to the granularity together with a time resolution of σt≤ 150 ps ensures high-resolution capabilities. In conjunction with calorimetric properties, a multi-neutron reconstruction efficiency of 50% to 70% for four-neutron events will be achieved, depending on both the emission scenario and the boundary conditions allowed for the reconstruction method. We present in this paper the final design of the detector as well as results from test measurements and simulations on which this design is based.
  •  
17.
  • Holl, Matthias, 1986, et al. (author)
  • Border of the island of inversion: Unbound states in Ne-29
  • 2022
  • In: Physical Review C. - 2469-9985 .- 2469-9993. ; 105:3
  • Journal article (peer-reviewed)abstract
    • The nucleus Ne-29 is situated at the border of the island of inversion. Despite significant efforts, no bound low-lying intruder f(7/2) state, which would place Ne-29 firmly inside the island of inversion, has yet been observed. Here, the first investigation of unbound states of Ne-29 is reported. The states were populated in Ne-30(p, pn) and Na-30(p, 2p) reactions at a beam energy of around 230 MeV/nucleon, and analyzed in terms of their resonance properties, partial cross sections, and momentum distributions. The momentum distributions are compared to calculations using the eikonal, direct reaction model, allowing assignments for the observed states. The lowest lying resonance at an excitation energy of 1.48(4) MeV shows clear signs of a significant l = 3 component, giving first evidence for f(7/2) single particle strength in Ne-29. The excitation energies and strengths of the observed states are compared to shell-model calculations using the SDPF-U-MIX interaction.
  •  
18.
  • Revel, A., et al. (author)
  • Extending the Southern Shore of the Island of Inversion to F-28
  • 2020
  • In: Physical Review Letters. - 1079-7114 .- 0031-9007. ; 124:15
  • Journal article (peer-reviewed)abstract
    • Detailed spectroscopy of the neutron-unbound nucleus F-28 has been performed for the first time following proton/neutron removal from Ne-29/F-29 beams at energies around 230 MeV=nucleon. The invariant-mass spectra were reconstructed for both the F-27((*)) + n and F-26((*)) + 2n coincidences and revealed a series of well-defined resonances. A near-threshold state was observed in both reactions and is identified as the F-28 ground state, with S-n(F-28) = -199(6) keV, while analysis of the 2n decay channel allowed a considerably improved S-n(F-27) = 1620(60) keV to be deduced. Comparison with shell-model predictions and eikonal-model reaction calculations have allowed spin-parity assignments to be proposed for some of the lower-lying levels of F-28. Importantly, in the case of the ground state, the reconstructed F-27 + n momentum distribution following neutron removal from F-29 indicates that it arises mainly from the 1p(3/2) neutron intruder configuration. This demonstrates that the island of inversion around N = 20 includes F-28, and most probably F-29, and suggests that O-28 is not doubly magic.
  •  
19.
  • Ponnath, L., et al. (author)
  • Measurement of nuclear interaction cross sections towards neutron-skin thickness determination
  • 2024
  • In: Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics. - 0370-2693. ; 855
  • Journal article (peer-reviewed)abstract
    • The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of [Formula presented] on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R3B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  •  
26.
  •  
27.
  •  
28.
  •  
29.
  •  
30.
  •  
31.
  • Heil, M., et al. (author)
  • A new Time-of-flight detector for the R 3 B setup
  • 2022
  • In: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-601X .- 1434-6001. ; 58:12
  • Journal article (peer-reviewed)abstract
    • We present the design, prototype developments and test results of the new time-of-flight detector (ToFD) which is part of the R3B experimental setup at GSI and FAIR, Darmstadt, Germany. The ToFD detector is able to detect heavy-ion residues of all charges at relativistic energies with a relative energy precision σΔE/ ΔE of up to 1% and a time precision of up to 14 ps (sigma). Together with an elaborate particle-tracking system, the full identification of relativistic ions from hydrogen up to uranium in mass and nuclear charge is possible.
  •  
32.
  • Quétel, C. R., et al. (author)
  • Methylmercury in tuna: demonstrating measurement capabilities and evaluating comparability of results worldwide from the CCQM P-39 comparison
  • 2005
  • In: Journal of Analytical Atomic Spectrometry. - : Royal Society of Chemistry (RSC). - 0267-9477 .- 1364-5544. ; 20, s. 1058-66
  • Journal article (peer-reviewed)abstract
    • Six metrology institutes (NMIs) representing at the Comité International des Poids et Mesures (CIPM) 4 Member States of the Metre Convention and 2 international organisations, and 8 expert laboratories selected outside CIPM have compared their capabilities to quantitatively measure methylmercury (MeHg) in a prepared tuna material containing approximately 4.3 mg kg–1 Hg. This comparison was the object of the CIPM–Comité Consultatif pour la Quantité de Matière (CCQM) Pilot Study 39, organised by the Institute for Reference Materials and Measurements (IRMM), from the European Commission—Joint Research Centre. Beside the test material itself, a bottle of the BCR-464 tuna Certified Reference Material (CRM) and an ampoule of IRMM-670, a 202Hg isotope enriched MeHg candidate isotopic CRM, were distributed to all participants, who were free to apply the measurement strategy of their choice. Four, including 1 NMI, relied on external calibration or the method of standard additions, whereas the other 10 implemented an isotope dilution mass spectrometry (IDMS) approach and chose to use the IRMM-670 for their measurements. Alkaline digestion at room temperature (with manual shaking) or high temperature (under sonication, oven or hot plate conditions) was employed by most participants, with hydrochloric acid leaching the second most popular choice. Alkylation (4 phenylations, 4 ethylations and 3 propylations) in the aqueous phase was preferred by a large majority over butylation by the Grignard reaction. All participants were requested to estimate the uncertainty associated with their results and 9 out of 14 stated relative combined uncertainties below 6%(k= 2). Despite this apparent consensus, the perception of which factor caused the largest contribution to this estimation differed among participants because of the differences in the analytical methodologies deployed but also because of wide differences of the concepts of uncertainty estimation. The mixture mode(MM) median, calculated also from the measurement uncertainties stated by the participants, was 1.967 ± 0.204 × 10–5 mol kg–1(95% confidence). Twelve of the results were re-grouped within a range of less than 0.3 × 10–5 mol kg–1(MM median = 1.967 ± 0.162 × 10–5 mol kg–1, 95% confidence): they nearly all (1 exception) overlapped with each other within k= 2 stated uncertainties. For the other 2 results the uncertainty seemed to have been particularly underestimated as they lay, respectively, at more than 20% above and less than –40% below the overall average. The relative standard deviation of the results of 9 laboratories out of the 10 that applied IDMS was about 2.6%. It can be assumed from the degree of equivalence shown by 12 out of 14 study participants that, at present, laboratories worldwide are potentially able to supply accurate results for MeHg in fish-type matrices (containing about 2 × 10–5 mol kg–1) within ±10% uncertainty. This encouraging outcome permitted scheduling of a follow-up CCQM-K43 key comparison for a lower MeHg content level in salmon tissues.
  •  
33.
  • Bott, Lukas Thomas, et al. (author)
  • Coulomb dissociation of O-16 into He-4 and C-12
  • 2023
  • In: NUCLEAR PHYSICS IN ASTROPHYSICS - X, NPA-X 2022. - : EDP Sciences. - 2100-014X. ; 279
  • Conference paper (peer-reviewed)abstract
    • We measured the Coulomb dissociation of O-16 into He-4 and C-12 within the FAIR Phase-0 program at GSI Helmholtzzentrum fur Schwerionenforschung Darmstadt, Germany. From this we will extract the photon dissociation cross section O-16(alpha,gamma)C-12, which is the time reversed reaction to C-12(alpha,gamma)O-16. With this indirect method, we aim to improve on the accuracy of the experimental data at lower energies than measured so far. The expected low cross section for the Coulomb dissociation reaction and close magnetic rigidity of beam and fragments demand a high precision measurement. Hence, new detector systems were built and radical changes to the (RB)-B-3 setup were necessary to cope with the high-intensity O-16 beam. All tracking detectors were designed to let the unreacted O-16 ions pass, while detecting the C-12 and He-4.
  •  
34.
  •  
35.
  • Conroy-Beam, Daniel, et al. (author)
  • Assortative mating and the evolution of desirability covariation
  • 2019
  • In: Evolution and human behavior. - : Elsevier. - 1090-5138 .- 1879-0607. ; 40:5, s. 479-491
  • Journal article (peer-reviewed)abstract
    • Mate choice lies dose to differential reproduction, the engine of evolution. Patterns of mate choice consequently have power to direct the course of evolution. Here we provide evidence suggesting one pattern of human mate choice-the tendency for mates to be similar in overall desirability-caused the evolution of a structure of correlations that we call the d factor. We use agent-based models to demonstrate that assortative mating causes the evolution of a positive manifold of desirability, d, such that an individual who is desirable as a mate along any one dimension tends to be desirable across all other dimensions. Further, we use a large cross-cultural sample with n = 14,478 from 45 countries around the world to show that this d-factor emerges in human samples, is a cross-cultural universal, and is patterned in a way consistent with an evolutionary history of assortative mating. Our results suggest that assortative mating can explain the evolution of a broad structure of human trait covariation.
  •  
36.
  • Conroy-Beam, Daniel, et al. (author)
  • Contrasting Computational Models of Mate Preference Integration Across 45 Countries
  • 2019
  • In: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 9
  • Journal article (peer-reviewed)abstract
    • Humans express a wide array of ideal mate preferences. Around the world, people desire romantic partners who are intelligent, healthy, kind, physically attractive, wealthy, and more. In order for these ideal preferences to guide the choice of actual romantic partners, human mating psychology must possess a means to integrate information across these many preference dimensions into summaries of the overall mate value of their potential mates. Here we explore the computational design of this mate preference integration process using a large sample of n = 14,487 people from 45 countries around the world. We combine this large cross-cultural sample with agent-based models to compare eight hypothesized models of human mating markets. Across cultures, people higher in mate value appear to experience greater power of choice on the mating market in that they set higher ideal standards, better fulfill their preferences in choice, and pair with higher mate value partners. Furthermore, we find that this cross-culturally universal pattern of mate choice is most consistent with a Euclidean model of mate preference integration.
  •  
37.
  • Douglas, Pamela S, et al. (author)
  • Comparison of an Initial Risk-Based Testing Strategy vs Usual Testing in Stable Symptomatic Patients With Suspected Coronary Artery Disease: The PRECISE Randomized Clinical Trial.
  • 2023
  • In: JAMA cardiology. - 2380-6591.
  • Journal article (peer-reviewed)abstract
    • Trials showing equivalent or better outcomes with initial evaluation using coronary computed tomography angiography (cCTA) compared with stress testing in patients with stable chest pain have informed guidelines but raise questions about overtesting and excess catheterization.To test a modified initial cCTA strategy designed to improve clinical efficiency vs usual testing (UT).This was a pragmatic randomized clinical trial enrolling participants from December 3, 2018, to May 18, 2021, with a median of 11.8 months of follow-up. Patients from 65 North American and European sites with stable symptoms of suspected coronary artery disease (CAD) and no prior testing were randomly assigned 1:1 to precision strategy (PS) or UT.PS incorporated the Prospective Multicenter Imaging Study for the Evaluation of Chest Pain (PROMISE) minimal risk score to quantitatively select minimal-risk participants for deferred testing, assigning all others to cCTA with selective CT-derived fractional flow reserve (FFR-CT). UT included site-selected stress testing or catheterization. Site clinicians determined subsequent care.Outcomes were clinical efficiency (invasive catheterization without obstructive CAD) and safety (death or nonfatal myocardial infarction [MI]) combined into a composite primary end point. Secondary end points included safety components of the primary outcome and medication use.A total of 2103 participants (mean [SD] age, 58.4 [11.5] years; 1056 male [50.2%]) were included in the study, and 422 [20.1%] were classified as minimal risk. The primary end point occurred in 44 of 1057 participants (4.2%) in the PS group and in 118 of 1046 participants (11.3%) in the UT group (hazard ratio [HR], 0.35; 95% CI, 0.25-0.50). Clinical efficiency was higher with PS, with lower rates of catheterization without obstructive disease (27 [2.6%]) vs UT participants (107 [10.2%]; HR, 0.24; 95% CI, 0.16-0.36). The safety composite of death/MI was similar (HR, 1.52; 95% CI, 0.73-3.15). Death occurred in 5 individuals (0.5%) in the PS group vs 7 (0.7%) in the UT group (HR, 0.71; 95% CI, 0.23-2.23), and nonfatal MI occurred in 13 individuals (1.2%) in the PS group vs 5 (0.5%) in the UT group (HR, 2.65; 95% CI, 0.96-7.36). Use of lipid-lowering (450 of 900 [50.0%] vs 365 of 873 [41.8%]) and antiplatelet (321 of 900 [35.7%] vs 237 of 873 [27.1%]) medications at 1 year was higher in the PS group compared with the UT group (both P < .001).An initial diagnostic approach to stable chest pain starting with quantitative risk stratification and deferred testing for minimal-risk patients and cCTA with selective FFR-CT in all others increased clinical efficiency relative to UT at 1 year. Additional randomized clinical trials are needed to verify these findings, including safety.ClinicalTrials.gov Identifier: NCT03702244.
  •  
38.
  •  
39.
  •  
40.
  •  
41.
  • Ekman, S., et al. (author)
  • Treatment (Tx) patterns and overall survival (OS) in patients (pts) with NSCLC in Sweden : A SCAN-LEAF study analysis from the I-O Optimise initiative
  • 2019
  • In: Annals of Oncology. - : Elsevier BV. - 0923-7534. ; 30:Suppl 2, s. 17-17
  • Conference paper (peer-reviewed)abstract
    • Background: As part of I-O Optimise, a multinational research platform providing real-world insights into the management of lung cancers, the SCAN-LEAF study aims to describe the epidemiology, clinical care and outcomes for pts with NSCLC in Scandinavia. We report initial Tx and OS for pts with NSCLC prior to the availability of immunotherapies in Sweden. Methods: The analysis includes all adult pts diagnosed with NSCLC at Uppsala and Karolinska (Stockholm) University Hospitals from 2012 to 2015 (follow-up to Dec 2016). Electronic medical record data were extracted using Pygargus CXP software and linked with national registries. Bespoke rule-based algorithms were applied to describe Tx patterns; Kaplan–Meier methods were used to estimate OS. Results: 2779 pts were diagnosed with incident NSCLC (median age, 70 yrs [range: 22–96; 14.2% ≥80]; male, 48.5%; histology: non-squamous (NSQ), 70.9%, squamous (SQ), 17.7%, other, 11.4%; stage distribution: I, 19.3%; II, 7.7%; IIIA, 12.3%; IIIB, 7.2%; IV, 51.2%). Initial Tx (≤6 months from diagnosis) by stage and yr of diagnosis is shown in the table. Median OS (months) for NSQ and SQ pts: not reached and 52.8 in stage I, 43.2 and 23.6 in stage II, 26.7 and 20.4 in stage IIIA, 12.5 and 12.9 in stage IIIB, and 7.6 and 6.1 in stage IV, respectively. Among stage IIIB–IV pts, 60.7% (NSQ) and 53.5% (SQ) had ≥1 line of systemic anti-cancer therapy (SACT); median OS was 12.2 (NSQ) and 10.4 (SQ) months in pts on SACT, and 3.1 (NSQ) and 3.7 (SQ) months in pts not on SACT. Ongoing analyses will assess factors associated with SACT receipt in stage IIIB–IV pts. Conclusions: Swedish pts with NSCLC had a high burden of disease, with most diagnosed at stage IV and a median OS of 1 yr in late-stage pts receiving SACT. There is also scope for improved prognosis in pts diagnosed at early stages, particularly in SQ pts. Future analyses will assess the potential impact of recent improvements in diagnostics and therapeutics on Tx patterns and OS in Swedish NSCLC pts.
  •  
42.
  •  
43.
  •  
44.
  •  
45.
  • Kocman, David, et al. (author)
  • Preparation and characterization of a soil reference material from a mercury contaminated site for comparability studies
  • 2006
  • In: Journal of Environmental Management. - : Elsevier BV. - 0301-4797 .- 1095-8630. ; 81:2, s. 146-154
  • Journal article (peer-reviewed)abstract
    • The preparation and characterization of a soil reference material (SOIL-1) from a site polluted with mercury due to the past mercury mining in Idrija, Slovenia is reported. Homogeneity tests and intercomparison exercises for total (T-Hg) and methylmercury (MeHg) were performed. In addition, selective sequential extraction was applied for Hg fractionation, and multielemental analyses were performed by k0 standardization neutron activation analysis (k0-INAA) and inductively coupled mass spectrometry (ICP-MS) for other trace elements. Comparison of different analytical methods, as well as the distribution of data were critically evaluated using descriptive statistics and analysis of variance (ANOVA). Due to the nugget effect (cinnabar particles representing more than 90% of the mercury), homogeneity for T-Hg determination was difficult to achieve. The intercomparison exercise indicated that in order to obtain comparable results for total mercury (T-Hg) sample decomposition by HF must be performed. These data are then in good agreement with nondestructive methods such as k0-INAA. Accepted reference values calculated taking into account the results obtained by six and three laboratories, respectively, were 67.1711.3mg kg-1 for T-Hg and 4.071.3 ng g-1 for MeHg (95% confidence intervals). However, the results obtained for Hg fractionation displayed significant differences in the organically bound fraction and elemental Hg. Results obtained by two laboratories using totally different analytical protocols for other elements showed excellent agreement for most elements. In summary, the results obtained for the SOIL-1 sample were of sufficient quality to suggest its use for quality control in laboratories dealing with mercury contaminated soils.
  •  
46.
  • Lorbek, G, et al. (author)
  • Lessons from hepatocyte-specific Cyp51 knockout mice: impaired cholesterol synthesis leads to oval cell-driven liver injury
  • 2015
  • In: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 5, s. 8777-
  • Journal article (peer-reviewed)abstract
    • We demonstrate unequivocally that defective cholesterol synthesis is an independent determinant of liver inflammation and fibrosis. We prepared a mouse hepatocyte-specific knockout (LKO) of lanosterol 14α-demethylase (CYP51) from the part of cholesterol synthesis that is already committed to cholesterol. LKO mice developed hepatomegaly with oval cell proliferation, fibrosis and inflammation, but without steatosis. The key trigger was reduced cholesterol esters that provoked cell cycle arrest, senescence-associated secretory phenotype and ultimately the oval cell response, while elevated CYP51 substrates promoted the integrated stress response. In spite of the oval cell-driven fibrosis being histologically similar in both sexes, data indicates a female-biased down-regulation of primary metabolism pathways and a stronger immune response in males. Liver injury was ameliorated by dietary fats predominantly in females, whereas dietary cholesterol rectified fibrosis in both sexes. Our data place defective cholesterol synthesis as a focus of sex-dependent liver pathologies.
  •  
47.
  •  
48.
  •  
49.
  •  
50.
  • Maurovich-Horvat, Lajos, et al. (author)
  • Optimal Operation of Combined Heat and Power under Uncertainty and Risk Aversion
  • 2016
  • In: Energy and Buildings. - : Elsevier BV. - 0378-7788 .- 1872-6178. ; 110, s. 415-425
  • Journal article (peer-reviewed)abstract
    • Despite the proven benefits of combined heat and power (CHP) and recently introduced subsidies to support it, CHP adoption has not met its targets. One of the possible reasons for this is risk from uncertain electricity and gas prices. To gain insights into the risk management of a CHP unit, we develop a multi-stage stochastic mean-risk optimisation model for the medium-term management of a distributed generation system with a gas-fired microturbine with heat recovery and a boiler. The model adopts the perspective of a large consumer that procures gas (for on-site generation) and electricity (for consumption) on the spot and futures markets. The consumer's risk aversion is incorporated into the model through the conditional value-at-risk (CVaR) measure. We show that CHP not only decreases the consumer's expected cost and risk exposure by 10% each but also improves expected energy efficiency by 4 percentage points and decreases expected CO2 emissions by 16%. The risk exposure can be further mitigated through the use of financial contracts.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-50 of 63

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view