1.
  • Fredäng Kämmerling, Nina, et al. (author)
  • A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
  • 2024
  • In: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 173
  • Journal article (peer-reviewed)abstract
    • Purpose: Scaphoid fractures in patients and assessment of healing using PCD-CT have, as far as we know, not yet been studied. Therefore, the aim was to compare photon counting detector CT (PCD-CT) with energy integrating detector CT (EID-CT) in terms of fracture visibility and evaluation of fracture healing. Method: Eight patients with scaphoid fracture were examined with EID-CT and PCD-CT within the first week posttrauma, and with additional scans at 4, 6 and 8 weeks. Our clinical protocol for wrist examination with EID-CT was used (CTDIvol 3.1 +/- 0.1 mGy, UHR kernel Ur77). For PCD-CT matched radiation dose, reconstruction kernel Br89. Quantitative analyses of noise, CNR, trabecular and cortical sharpness, and bone volume fraction were conducted. Five radiologists evaluated the images for fracture visibility, fracture gap consolidation and image quality, and rated their confidence in the diagnosis. Results: The trabecular and cortical sharpness were superior in images obtained with PCD-CT compared with EIDCT. A successive reduction in trabecular bone volume fraction during the immobilized periods was found with both systems. Despite higher noise and lower CNR with PCD-CT, radiologists rated the image quality of PCD-CT as superior. The visibility of the fracture line within 1 -week post -trauma was rated higher with PCD-CT as was diagnostic confidence, but the subsequent assessments of fracture gap consolidation during healing process and the confidence in diagnosis were found equivalent between both systems. Conclusion: PCD-CT offers superior visibility of bone microstructure compared with EID-CT. The evaluation of fracture healing and confidence in diagnosis were rated equally with both systems, but the radiologists found primary fracture visibility and overall image quality superior with PCD-CT.
  •  
2.
  • Halilic, Senija, et al. (author)
  • Värdet av DT-buköversikt som primär undersökning vid akut buksmärta
  • 2016
  • Reports (other academic/artistic)abstract
    • Syftet med studien var att se hur stor andel av de patienter som genomgått DT-BÖS vid akut påkomna buksymptom som behöver genomgå kompletterande undersökning, samt vilken diagnos som ställdes vid den kompletterande undersökningen. Vilka frågeställningar besvarar DT-BÖS vid akut påkommen buksmärta? Vilka frågeställningar motiverar annan  undersökning som förstahandsundersökning?
  •  
3.
  • Kämmerling, Nina, et al. (author)
  • Assessment of image quality in photon-counting detector computed tomography of the wrist - An ex vivo study
  • 2022
  • In: European Journal of Radiology. - : Elsevier Ireland Ltd. - 0720-048X .- 1872-7727. ; 154
  • Journal article (peer-reviewed)abstract
    • Purpose: The aim of this study was to evaluate the effect of reconstruction parameters on image quality in wrist imaging using photon-counting detector CT (PCD-CT) and to compare the results with images from an energyintegrating detector CT (EID-CT). Methods: Twelve cadaveric wrist specimens were examined using a prototype PCD-CT and a clinical EID-CT using similar radiation dose. Reconstruction parameters were matched between scanners. Also, sharper reconstruction kernels, a larger matrix size, and smaller slice thicknesses were evaluated for PCD-CT. Image noise, contrast-tonoise ratio (CNR) and image sharpness in trabecular structures were quantitatively measured. Image quality with respect to the visibility of cortical and trabecular bone structures was assessed by six radiologists using visual grading methods.Results: Images obtained with PCD-CT had lower noise (42.6 +/- 3.9 HU vs 75.1 +/- 6.3 HU), higher CNR (38.9 +/- 4.5 vs 19.0 +/- 2.4) and higher trabecular sharpness (63.5 +/- 6.0 vs 53.7 +/- 8.5) than those obtained with EID-CT using similar scan and reconstruction parameters (p < 0.001). The image sharpness in trabecular structures was further improved by using sharper kernels, despite higher noise levels. Radiologists had a strong preference for PCD-CT images both in terms of spatial resolution and suitability for bone imaging. Visual grading analysis showed an improved visibility of cortical bone, trabeculae and nutritive canals (p < 0.005).Conclusion: PCD-CT offers improved image quality regarding bone structures in the wrist relative to EID-CT systems, particularly when sharper reconstruction kernels, smaller slice thickness and a larger image matrix size are used.
  •  