SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Pistiolis L.) "

Search: WFRF:(Pistiolis L.)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Hersi, Abdi-Fatah, et al. (author)
  • Optimizing Dose and Timing in Magnetic Tracer Techniques for Sentinel Lymph Node Detection in Early Breast Cancers: The Prospective Multicenter SentiDose Trial
  • 2021
  • In: Cancers. - : MDPI AG. - 2072-6694. ; 13:4
  • Journal article (peer-reviewed)abstract
    • Simple Summary Superparamagnetic iron oxide (SPIO) nanoparticles have comparable performance to the combination of radioisotope and blue dye (RI + BD) for sentinel lymph node (SLN) biopsy in breast cancer. In this multicenter prospective study, lower SPIO doses (undiluted 1.5 vs. 1.0 mL) in different timeframes (perioperative vs. 1-7 days preoperative) and injection sites (subareolar vs. peritumoral) were compared to the previous standard (diluted 2.0 mL perioperatively) from the earlier Nordic trial. RI + BD were co-administered as background. In total, 534 patients were analyzed. SPIO SLN detection rates were similar (97.5% vs. 100% vs. 97.6%, p = 0.11) and respectively non-inferior to the dual technique. Significantly more SLNs were retrieved in the preoperative 1.0 mL cohort compared with 1.5 mL and the Nordic cohorts (2.18 vs. 1.85 vs. 1.83, p = 0.003). Thus, SPIO at 1.5 and 1.0 mL was non-inferior to both Sienna+(R) and the dual technique for SLN detection. Superparamagnetic iron oxide nanoparticles (SPIO) are non-inferior to radioisotope and blue dye (RI + BD) for sentinel lymph node (SLN) detection. Previously, 2 mL SPIO (Sienna+(R)) in 3 mL NaCl was used. In this dose-optimizing study, lower doses of a new refined SPIO solution (Magtrace(R)) (1.5 vs. 1.0 mL) were tested in different timeframes (0-24 h perioperative vs. 1-7 days preoperative) and injections sites (subareolar vs. peritumoral). Two consecutive breast cancer cohorts (n = 328) scheduled for SLN-biopsy were included from 2017 to 2019. All patients received isotope +/- blue dye as back-up. SLNs were identified primarily with the SentiMag(R) probe and thereafter a gamma-probe. The primary endpoint was SLN detection rate with SPIO. Analyses were performed as a one-step individual patient-level meta-analysis using patient-level data from the previously published Nordic Trial (n = 206) as a third, reference cohort. In 534 patients, the SPIO SLN detection rates were similar (97.5% vs. 100% vs. 97.6%, p = 0.11) and non-inferior to the dual technique. Significantly more SLNs were retrieved in the preoperative 1.0 mL cohort compared with 1.5 and the 2.0 mL cohorts (2.18 vs. 1.85 vs. 1.83, p = 0.003). Lower SPIO volumes injected up to 7 days before the operation have comparable efficacy to standard SPIO dose and RI + BD for SLN detection.
  •  
2.
  • Karakatsanis, Andreas, et al. (author)
  • Effect of preoperative injection of superparamagnetic iron oxide particles on rates of sentinel lymph node dissection in women undergoing surgery for ductal carcinoma in situ (SentiNot study)
  • 2019
  • In: British Journal of Surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 106:6
  • Journal article (peer-reviewed)abstract
    • Background: One-fifth of patients with a preoperative diagnosis of ductal carcinoma in situ (DCIS) have invasive breast cancer (IBC) on definitive histology. Sentinel lymph node dissection (SLND) is performed in almost half of women having surgery for DCIS in Sweden. The aim of the present study was to try to minimize unnecessary SLND by injecting superparamagnetic iron oxide (SPIO) nanoparticles at the time of primary breast surgery, enabling SLND to be performed later, if IBC is found in the primary specimen. Methods: Women with DCIS at high risk for the presence of invasion undergoing breast conservation, and patients with DCIS undergoing mastectomy were included. The primary outcome was whether this technique could reduce SLND. Secondary outcomes were number of SLNDs avoided, detection rate and procedure-related costs. Results: This was a preplanned interim analysis of 189 procedures. IBC was found in 47 and a secondary SLND was performed in 41 women. Thus, 78.3 per cent of patients avoided SLND (P<0.001). At reoperation, SPIO plus blue dye outperformed isotope and blue dye in detection of the sentinel node (40 of 40 versus 26 of 40 women; P<0.001). Costs were reduced by a mean of 24.5 per cent in women without IBC (3990 versus 5286; P<0.001). Conclusion: Marking the sentinel node with SPIO in women having surgery for DCIS was effective at avoiding unnecessary SLND in this study. Registration number: ISRCTN18430240 (http://www.isrctn.com).
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view