SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Plate A) "

Search: WFRF:(Plate A)

  • Result 1-10 of 10
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  • Bahl, A, et al. (author)
  • PROTEOMAS: a workflow enabling harmonized proteomic meta-analysis and proteomic signature mapping
  • 2023
  • In: Journal of cheminformatics. - : Springer Science and Business Media LLC. - 1758-2946. ; 15:1, s. 34-
  • Journal article (peer-reviewed)abstract
    • Toxicological evaluation of substances in regulation still often relies on animal experiments. Understanding the substances’ mode-of-action is crucial to develop alternative test strategies. Omics methods are promising tools to achieve this goal. Until now, most attention was focused on transcriptomics, while proteomics is not yet routinely applied in toxicology despite the large number of datasets available in public repositories. Exploiting the full potential of these datasets is hampered by differences in measurement procedures and follow-up data processing. Here we present the tool PROTEOMAS, which allows meta-analysis of proteomic data from public origin. The workflow was designed for analyzing proteomic studies in a harmonized way and to ensure transparency in the analysis of proteomic data for regulatory purposes. It agrees with the Omics Reporting Framework guidelines of the OECD with the intention to integrate proteomics to other omic methods in regulatory toxicology. The overarching aim is to contribute to the development of AOPs and to understand the mode of action of substances. To demonstrate the robustness and reliability of our workflow we compared our results to those of the original studies. As a case study, we performed a meta-analysis of 25 proteomic datasets to investigate the toxicological effects of nanomaterials at the lung level. PROTEOMAS is an important contribution to the development of alternative test strategies enabling robust meta-analysis of proteomic data. This workflow commits to the FAIR principles (Findable, Accessible, Interoperable and Reusable) of computational protocols.
  •  
4.
  • Bahl, A, et al. (author)
  • PROTEOMAS: a workflow enabling harmonized proteomic meta-analysis and proteomic signature mapping
  • 2023
  • In: Journal of cheminformatics. - : Springer Science and Business Media LLC. - 1758-2946. ; 15:1, s. 34-
  • Journal article (peer-reviewed)abstract
    • Toxicological evaluation of substances in regulation still often relies on animal experiments. Understanding the substances’ mode-of-action is crucial to develop alternative test strategies. Omics methods are promising tools to achieve this goal. Until now, most attention was focused on transcriptomics, while proteomics is not yet routinely applied in toxicology despite the large number of datasets available in public repositories. Exploiting the full potential of these datasets is hampered by differences in measurement procedures and follow-up data processing. Here we present the tool PROTEOMAS, which allows meta-analysis of proteomic data from public origin. The workflow was designed for analyzing proteomic studies in a harmonized way and to ensure transparency in the analysis of proteomic data for regulatory purposes. It agrees with the Omics Reporting Framework guidelines of the OECD with the intention to integrate proteomics to other omic methods in regulatory toxicology. The overarching aim is to contribute to the development of AOPs and to understand the mode of action of substances. To demonstrate the robustness and reliability of our workflow we compared our results to those of the original studies. As a case study, we performed a meta-analysis of 25 proteomic datasets to investigate the toxicological effects of nanomaterials at the lung level. PROTEOMAS is an important contribution to the development of alternative test strategies enabling robust meta-analysis of proteomic data. This workflow commits to the FAIR principles (Findable, Accessible, Interoperable and Reusable) of computational protocols.
  •  
5.
  •  
6.
  •  
7.
  • Lundgren, Fredrik, et al. (author)
  • PTFE bypass to below-knee arteries : distal vein collar or not? A prospective randomised multicentre study
  • 2010
  • In: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 39:6, s. 747-754
  • Journal article (peer-reviewed)abstract
    • BackgroundPatency and limb salvage after synthetic bypass to the arteries below-knee are inferior to that which can be achieved with autologous vein. Use of a vein collar at the distal anastomosis has been suggested to improve patency and limb salvage, a problem that is analysed in this randomised clinical study.MethodsPatients with critical limb ischaemia undergoing polytetrafluoroethylene (PTFE) bypass to below-knee arteries were randomly either assigned a vein collar or not in two groups – bypass to the popliteal artery below-knee (femoro-popliteal below-knee (FemPopBK)) and more distal bypass (femoro-distal bypass (FemDist)). Follow-up was scheduled until amputation, death or at most 5 years, whichever event occurred first.ResultsIn the FemPopBK and in the FemDist groups, 115/202 and 72/150 were randomised to have a vein collar, respectively. Information was available for 345 of 352 randomised patients (98%).At 3 years, primary patency was 26% (95% confidence interval (CI) 18–38) with a vein collar and 43 (33–58) without a vein collar for femoro-popliteal bypass and 20 (11–38), and 17 (9–33) for femoro-distal bypass, respectively. The corresponding figures for limb salvage were 64 (54–75) and 61 (50–74) for femoro-popliteal bypass, and 59 (46–76) and 44 (32–61) for femoro-distal bypass with and without a vein collar, respectively. Log-rank-test for the whole Kaplan–Meier life table curve showed no statistically significant differences with or without vein collar primary patency: p = 0.0853, p = 0.228; secondary patency: p = 0.317, p = 0.280; limb salvage: p = 0.757, p = 0.187 for FemPopBK and FemDist, respectively. The use of a vein collar did not influence patency or limb salvage.ConclusionThis study failed to show any benefit for vein collar with PTFE bypass to a below-knee artery.
  •  
8.
  •  
9.
  •  
10.
  • Bergqvist, David, et al. (author)
  • Secondary aortoenteric fistula : changes from 1973 to 1993
  • 1996
  • In: European Journal of Vascular and Endovascular Surgery. - 1078-5884 .- 1532-2165. ; 11:4, s. 425-428
  • Journal article (peer-reviewed)abstract
    • AIM: To investigate a series of patients with secondary aortoenteric fistulas and compare it with a previous series (1985-93 vs. 1973-84). DESIGN: Retrospective study of medical records. SETTING: Sixteen vascular surgical centers in Sweden. PATIENTS: Twenty-seven patients were identified making an overall incidence of 0.5% of all aortoiliac operations. Among aneurysm patients the incidence was significantly lower than in the previous series. One patient record could not be identified. Fourteen primary operations were for aortic aneurysm, 12 for occlusive disease and one was an aortorenal vein bypass. RESULTS: Symptoms of the fistula occurred after a median interval of 90 months which is significantly later than the previous series (32 months; p<0.05). The commonest presentation was bleeding followed by septis. The median diagnostic delay was 10.5 days, which was significantly shorter than in the previous series. Most fistulas involved the duodenum (88%). One patient died before surgery. The postoperative mortality was 28%, significantly lower than in the previous series (58%) (p<0.05). At the end of follow up (median 43 months) significantly more patients were alive than in the previous series (42% vs 18%) (p<0.05). CONCLUSION: Over a 21 year period there seems to have been a decrease in the frequency of secondary aortoenteric fistulas after aneurysm surgery, a longer interval before they occur, a shorter diagnostic delay, and a better survival.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view