SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Vetter V. L.) "

Search: WFRF:(Vetter V. L.)

  • Result 1-19 of 19
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Abat, E., et al. (author)
  • A layer correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
  • 2011
  • In: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221. ; 6
  • Journal article (peer-reviewed)abstract
    • A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
  •  
3.
  • Abat, E., et al. (author)
  • Combined performance studies for electrons at the 2004 ATLAS combined test-beam
  • 2010
  • In: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221. ; 5, s. P11006-
  • Journal article (peer-reviewed)abstract
    • In 2004 at the ATLAS (A Toroidal LHC ApparatuS) combined test beam, one slice of the ATLAS barrel detector (including an Inner Detector set-up and the Liquid Argon calorimeter) was exposed to particles from the H8 SPS beam line at CERN. It was the first occasion to test the combined electron performance of ATLAS. This paper presents results obtained for the momentum measurement p with the Inner Detector and for the performance of the electron measurement with the LAr calorimeter (energy E linearity and resolution) in the presence of a magnetic field in the Inner Detector for momenta ranging from 20 GeV/c to 100 GeV/c. Furthermore the particle identification capabilities of the Transition Radiation Tracker, Bremsstrahlungs-recovery algorithms relying on the LAr calorimeter and results obtained for the E/p ratio and a way how to extract scale parameters will be discussed.
  •  
4.
  • Abat, E., et al. (author)
  • Photon reconstruction in the ATLAS Inner Detector and Liquid Argon Barrel Calorimeter at the 2004 Combined Test Beam
  • 2011
  • In: Journal of Instrumentation. - 1748-0221. ; 6
  • Journal article (peer-reviewed)abstract
    • The reconstruction of photons in the ATLAS detector is studied with data taken during the 2004 Combined Test Beam, where a full slice of the ATLAS detector was exposed to beams of particles of known energy at the CERN SPS. The results presented show significant differences in the longitudinal development of the electromagnetic shower between converted and unconverted photons as well as in the total measured energy. The potential to use the reconstructed converted photons as a means to precisely map the material of the tracker in front of the electromagnetic calorimeter is also considered. All results obtained are compared with a detailed Monte-Carlo simulation of the test-beam setup which is based on the same simulation and reconstruction tools as those used for the ATLAS detector itself.
  •  
5.
  • Abata, E., et al. (author)
  • Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
  • 2010
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 621:1-3, s. 134-150
  • Journal article (peer-reviewed)abstract
    • A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20-350 GeV and beam impact points and angles corresponding to pseudo-rapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit. (C) 2010 Published by Elsevier B.V.
  •  
6.
  • Abat, E., et al. (author)
  • Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
  • 2009
  • In: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 607:2, s. 372-386
  • Journal article (peer-reviewed)abstract
    • A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. in this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4. (C) 2009 Elsevier B.V. All rights reserved.
  •  
7.
  •  
8.
  • Abgrall, N., et al. (author)
  • The large enriched germanium experiment for neutrinoless double beta decay (LEGEND)
  • 2017
  • In: AIP Conference Proceedings. - : Author(s). - 1551-7616 .- 0094-243X. ; 1894
  • Conference paper (peer-reviewed)abstract
    • The observation of neutrinoless double-beta decay (0νββ) would show that lepton number is violated, reveal that neu-trinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of ∼0.1 count /(FWHM·t·yr) in the region of the signal. The current generation 76Ge experiments GERDA and the Majorana Demonstrator, utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0νββ signal region of all 0νββ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale 76Ge experiment. The collaboration aims to develop a phased 0νββ experimental program with discovery potential at a half-life approaching or at 1028 years, using existing resources as appropriate to expedite physics results.
  •  
9.
  • Shepherd, L., et al. (author)
  • Infection-related and -unrelated malignancies, HIV and the aging population
  • 2016
  • In: HIV Medicine. - : Wiley. - 1464-2662 .- 1468-1293. ; 17:8, s. 590-600
  • Journal article (peer-reviewed)abstract
    • Objectives: HIV-positive people have increased risk of infection-related malignancies (IRMs) and infection-unrelated malignancies (IURMs). The aim of the study was to determine the impact of aging on future IRM and IURM incidence. Methods: People enrolled in EuroSIDA and followed from the latest of the first visit or 1 January 2001 until the last visit or death were included in the study. Poisson regression was used to investigate the impact of aging on the incidence of IRMs and IURMs, adjusting for demographic, clinical and laboratory confounders. Linear exponential smoothing models forecasted future incidence. Results: A total of 15 648 people contributed 95 033 person-years of follow-up, of whom 610 developed 643 malignancies [IRMs: 388 (60%); IURMs: 255 (40%)]. After adjustment, a higher IRM incidence was associated with a lower CD4 count [adjusted incidence rate ratio (aIRR) CD4 count < 200 cells/μL: 3.77; 95% confidence interval (CI) 2.59, 5.51; compared with ≥ 500 cells/μL], independent of age, while a CD4 count < 200 cells/μL was associated with IURMs in people aged < 50 years only (aIRR: 2.51; 95% CI 1.40–4.54). Smoking was associated with IURMs (aIRR: 1.75; 95% CI 1.23, 2.49) compared with never smokers in people aged ≥ 50 years only, and not with IRMs. The incidences of both IURMs and IRMs increased with older age. It was projected that the incidence of IRMs would decrease by 29% over a 5-year period from 3.1 (95% CI 1.5–5.9) per 1000 person-years in 2011, whereas the IURM incidence would increase by 44% from 4.1 (95% CI 2.2–7.2) per 1000 person-years over the same period. Conclusions: Demographic and HIV-related risk factors for IURMs (aging and smoking) and IRMs (immunodeficiency and ongoing viral replication) differ markedly and the contribution from IURMs relative to IRMs will continue to increase as a result of aging of the HIV-infected population, high smoking and lung cancer prevalence and a low prevalence of untreated HIV infection. These findings suggest the need for targeted preventive measures and evaluation of the cost−benefit of screening for IURMs in HIV-infected populations.
  •  
10.
  • Althueser, L., et al. (author)
  • GPU-based optical simulation of the DARWIN detector
  • 2022
  • In: Journal of Instrumentation. - 1748-0221. ; 17:7
  • Journal article (peer-reviewed)abstract
    • Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.
  •  
11.
  •  
12.
  • Drezner, J. A., et al. (author)
  • International criteria for electrocardiographic interpretation in athletes: Consensus statement
  • 2017
  • In: Br J Sports Med. - : BMJ. - 0306-3674. ; 51:9, s. 704-731
  • Journal article (peer-reviewed)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly, advanced by a growing body of scientific data and investigations that both examine proposed criteria sets and establish new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington (USA), to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD.
  •  
13.
  • Dujon, B, et al. (author)
  • The nucleotide sequence of Saccharomyces cerevisiae chromosome XV
  • 1997
  • In: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 387:6632, s. 98-102
  • Journal article (peer-reviewed)abstract
    • Chromosome XV was one of the last two chromosomes of Saccharomyces cerevisiae to be discovered(1). It is the third-largest yeast chromosome after chromosomes XII and IV, and is very similar in size to chromosome VII. It alone represents 9% of the yeast genome (8% if ribosomal DNA is included). When systematic sequencing of chromosome XV was started, 93 genes or markers were identified, and most of them were mapped(2). However, very little else was known about chromosome XV which, in contrast to shorter chromosomes, had not been the object of comprehensive genetic or molecular analysis. It was therefore decided to start sequencing chromosome XV only in the third phase of the European Yeast Genome Sequencing Programme, after experience was gained on chromosomes III, XI and II (refs 3-5). The sequence of chromosome XV has been determined from a set of partly overlapping cosmid clones derived from a unique yeast strain, and physically mapped at 3.3-kilobase resolution before sequencing. As well as numerous new open reading frames (ORFs) and genes encoding tRNA or small RNA molecules, the sequence of 1,091,283 base pairs confirms the high proportion of orphan genes and reveals a number of ancestral and successive duplications with other yeast chromosomes.
  •  
14.
  • Sharma, S., et al. (author)
  • International Recommendations for Electrocardiographic Interpretation in Athletes
  • 2017
  • In: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097. ; 69:8, s. 1057-1075
  • Journal article (peer-reviewed)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural, or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly over the last decade; pushed by a growing body of scientific data that both tests proposed criteria sets and establishes new evidence to guide refinements. On February 26-27, 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington, to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD. (C) 2017 The Authors. Published by Elsevier Inc. on behalf of American College of Cardiology Foundation. All rights reserved.
  •  
15.
  • Sharma, S., et al. (author)
  • International recommendations for electrocardiographic interpretation in athletes
  • 2018
  • In: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 39:16, s. 1466-1480
  • Journal article (peer-reviewed)abstract
    • Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural, or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly over the last decade; pushed by a growing body of scientific data that both tests proposed criteria sets and establishes new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington, to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD.
  •  
16.
  •  
17.
  •  
18.
  • Barker, ED, et al. (author)
  • Do ADHD-impulsivity and BMI have shared polygenic and neural correlates?
  • 2021
  • In: Molecular psychiatry. - : Springer Science and Business Media LLC. - 1476-5578 .- 1359-4184. ; 26:3, s. 1019-1028
  • Journal article (peer-reviewed)abstract
    • There is an extensive body of literature linking ADHD to overweight and obesity. Research indicates that impulsivity features of ADHD account for a degree of this overlap. The neural and polygenic correlates of this association have not been thoroughly examined. In participants of the IMAGEN study, we found that impulsivity symptoms and body mass index (BMI) were associated (r = 0.10, n = 874, p = 0.014 FWE corrected), as were their respective polygenic risk scores (PRS) (r = 0.17, n = 874, p = 6.5 × 10−6 FWE corrected). We then examined whether the phenotypes of impulsivity and BMI, and the PRS scores of ADHD and BMI, shared common associations with whole-brain grey matter and the Monetary Incentive Delay fMRI task, which associates with reward-related impulsivity. A sparse partial least squared analysis (sPLS) revealed a shared neural substrate that associated with both the phenotypes and PRS scores. In a last step, we conducted a bias corrected bootstrapped mediation analysis with the neural substrate score from the sPLS as the mediator. The ADHD PRS associated with impulsivity symptoms (b = 0.006, 90% CIs = 0.001, 0.019) and BMI (b = 0.009, 90% CIs = 0.001, 0.025) via the neuroimaging substrate. The BMI PRS associated with BMI (b = 0.014, 95% CIs = 0.003, 0.033) and impulsivity symptoms (b = 0.009, 90% CIs = 0.001, 0.025) via the neuroimaging substrate. A common neural substrate may (in part) underpin shared genetic liability for ADHD and BMI and the manifestation of their (observable) phenotypic association.
  •  
19.
  • Karlgren, Daniel, et al. (author)
  • High-angular-momentum structures in Zn-64
  • 2004
  • In: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 69, s. 1-034330
  • Journal article (peer-reviewed)abstract
    • High-angular-momentum states in Zn-64 were populated in the Ca-40(Si-28,4p) reaction at a beam energy of 122 MeV. Evaporated, light, charged particles were identified by the Microball, while gamma rays were detected using the Gammasphere array. The main focus of this paper is on two strongly coupled, collective bands. The yrast band, which was previously known, has been linked to lower-lying states establishing the excitation energies and angular momenta of in-band states for the first time. The newly identified excited band decays to the yrast band but firm angular-momentum assignments could not be made. In order to interpret these structures cranked-Nilsson-Strutinsky calculations have been performed. The calculations have been extended to account for the distribution of nucleons within a configuration. The yrast collective band is interpreted as based on the pi(f(7/2))(-1)(p(3/2)f(5/2))(2)(g(9/2))(1)nu(p(3/2)f(5/2))(4)(g(9/2))(2) configuration. There are several possible interpretations of the second band but it is difficult to distinguish between the different possibilities.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-19 of 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view