SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Wollenberger U.) "

Search: WFRF:(Wollenberger U.)

  • Result 1-5 of 5
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Nistor, Catalin, et al. (author)
  • Detection of Escherichia coli in water by culture-based amperometric and luminometric methods.
  • 2002
  • In: Water Science and Technology. - 0273-1223. ; 45:4-5, s. 191-199
  • Journal article (peer-reviewed)abstract
    • The application of amperometric biosensor- and chemiluminiscence based methods for rapid detection of viable E. coli in water has been investigated. An amplification of the amperometric signal by a factor of 4 was obtained when the cellobiose dehydrogenase (CDH) biosensor was used instead of a plain graphite electrode for detection of b-galactosidase (b-GAL) activity at 22.5 degrees C. A linear correlation was demonstrated for detection time (DT) vs. initial concentrations (logarithmic units) of E. coli IT1 and E. coli in environmental samples, respectively, by use of the CDH biosensor or a chemiluminometric technique. The study has shown that an E. coli concentration > or = 10(4) cfu/100 mL in environmental samples was determined by the CDH biosensor within one working day. However, further reduction of the DT can be obtained, e.g. by increasing the signal amplification factor using other biosensors.
  •  
2.
  • Nistor, Catalin, et al. (author)
  • In-field monitoring of cleaning efficiency in waste water treatment plants using two phenol-sensitive biosensors
  • 2002
  • In: Analytica Chimica Acta. - 1873-4324. ; 456:1, s. 3-17
  • Journal article (peer-reviewed)abstract
    • Two amperometric biosensors based on the enzymes cellobiose dehydrogenase (CDH) and quinoprotein-dependent glucose dehydrogenase (GDH), have been applied for monitoring the phenolic content in water samples, collected at different stages of a waste water treatment process, thus representing different cleaning levels of two waste water treatment plants (WWTPs). The biosensor measurements were performed in-field, compared with the results obtained by liquid chromatography-mass spectrometry and were further correlated with the cleaning efficiencies of the WWTPs. The effect of several potentially interfering compounds on the sensor response was also studied. The general purpose of the study was to evaluate the potential use of biosensors, not as quantitative tools for phenol analysis, but rather as screening tools indicating a certain trend, i.e. compounds present or not present, and potential correlation with sample toxicity. It was found that the biosensors and LC-MS results were not quantitatively comparable, however, both sensors could follow the decrease of the phenol content from the influent, primary treated and effluent waters. In addition, the correlation between biosensor inhibition and sample toxicity is discussed.
  •  
3.
  • Rose, A, et al. (author)
  • GDH biosensor based off-line capillary immunoassay for alkylphenols and their ethoxylates
  • 2002
  • In: Biosensors & Bioelectronics. - 1873-4235. ; 17:11-12, s. 1033-1043
  • Journal article (peer-reviewed)abstract
    • The application of a quinoprotein glucose dehydrogenase modified thick-film sensor as label detector in a capillary immunoassay (CIA) for xenoestrogens is presented. The detection of the alkylphenols and their ethoxylates is based on the competition between the analyte and tracer molecules for the binding sites of anti-alkylphenol ethoxylate antibodies. This assay is performed off-line in small disposable PVC capillaries coated with immobilized antibodies. This format allows the combination of the assay with a small portable device potentially useful for on-site environmental monitoring. Beside high amplification the utilization of beta-galactosidase as enzyme label allows the direct combination with a GDH biosensor at optimal pH conditions. The bioelectrocatalytic properties of this biosensor offer an additional amplification and thus allow a very sensitive quantification of 4-aminophenol, generated by the beta-galactosidase. Detection limits of the analytes in the mug/l range were obtained, while other phenolics and surfactants showed no or very little cross reactivity.
  •  
4.
  • Schulte-Oehlmann, U, et al. (author)
  • COMPRENDO: Focus and approach.
  • 2006
  • In: Environmental Health Perspectives. - : Environmental Health Perspectives. - 1552-9924 .- 0091-6765. ; 114:Supplement 1, s. 98-100
  • Journal article (peer-reviewed)abstract
    • Tens of thousands of man-made chemicals are in regular use and discharged into the environment. Many of them are known to interfere with the hormonal systems in humans and wildlife. Given the complexity of endocrine systems, there are many ways in which endocrine-disrupting chemicals (EDCs) can affect the body's signaling system, and this makes unraveling the mechanisms of action of these chemicals difficult. A major concern is that some of these EDCs appear to be biologically active at extremely low concentrations. There is growing evidence to indicate that the guiding principle of traditional toxicology that "the dose makes the poison" may not always be the case because some EDCs do not induce the classical dose-response relationships. The European Union project COMPRENDO (Comparative Research on Endocrine Disrupters--Phylogenetic Approach and Common Principles focussing on Androgenic/Antiandrogenic Compounds) therefore aims to develop an understanding of potential health problems posed by androgenic and antiandrogenic compounds (AACs) to wildlife and humans by focusing on the commonalities and differences in responses to AACs across the animal kingdom (from invertebrates to vertebrates) .
  •  
5.
  • Zor, K., et al. (author)
  • A compact multifunctional microfluidic platform for exploring cellular dynamics in real-time using electrochemical detection
  • 2014
  • In: RSC Advances. - : Royal Society of Chemistry (RSC). - 2046-2069. ; 4:109, s. 63761-63771
  • Journal article (peer-reviewed)abstract
    • Downscaling of microfluidic cell culture and detection devices for electrochemical monitoring has mostly focused on miniaturization of the microfluidic chips which are often designed for specific applications and therefore lack functional flexibility. We present a compact microfluidic cell culture and electrochemical analysis platform with in-built fluid handling and detection, enabling complete cell based assays comprising on-line electrode cleaning, sterilization, surface functionalization, cell seeding, cultivation and electrochemical real-time monitoring of cellular dynamics. To demonstrate the versatility and multifunctionality of the platform, we explored amperometric monitoring of intracellular redox activity in yeast (Saccharomyces cerevisiae) and detection of exocytotically released dopamine from rat pheochromocytoma cells (PC12). Electrochemical impedance spectroscopy was used in both applications for monitoring cell sedimentation and adhesion as well as proliferation in the case of PC12 cells. The influence of flow rate on the signal amplitude in the detection of redox metabolism as well as the effect of mechanical stimulation on dopamine release were demonstrated using the programmable fluid handling capability. The here presented platform is aimed at applications utilizing cell based assays, ranging from e.g. monitoring of drug effects in pharmacological studies, characterization of neural stem cell differentiation, and screening of genetically modified microorganisms to environmental monitoring.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-5 of 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view