Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk material och protesteknik) "

Search: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk material och protesteknik)

  • Result 1-50 of 515
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Johansson, Martin L, et al. (author)
  • Non-invasive sampling procedure revealing the molecular events at different abutments of bone-anchored hearing systems–A prospective clinical pilot study
  • 2022
  • In: Frontiers in Neuroscience. - : Frontiers Media SA. - 1662-4548 .- 1662-453X. ; 16
  • Journal article (peer-reviewed)abstract
    • Purpose: To investigate the molecular activities in different compartments around the bone-anchored hearing system (BAHS) with either electropolished or machined abutments and to correlate these activities with clinical and microbiological findings. Materials and methods: Twelve patients received machined or electropolished abutments after implant installation of BAHS. Peri-abutment fluid and tissue were collected from baseline to 12 months. Gene expression of cytokines and factors related to tissue healing and inflammation, regeneration and remodelling, as well as bacterial recognition were determined using quantitative-polymerase chain reaction (qPCR). The clinical status was evaluated using the Holgers scoring system, and bacterial colonisation was investigated by culturing. Results: The gene expression of inflammatory cytokines (IL-8, IL-1β, and IL-10) and bacteria-related Toll-like receptors (2 and 4) was higher in the peri-abutment fluid than at baseline and in the peri-abutment tissue at 3 and 12 months. Conversely, the expression of genes related to tissue regeneration (Coll1a1 and FOXO1) was higher in the tissue samples than in the peri-abutment fluid at 3 and 12 months. Electropolished abutments triggered higher expression of inflammatory cytokines (IL-8 and IL-1β) (in peri-abutment fluid) and regeneration factor FOXO1 (in peri-abutment tissue) than machined abutments. Several cytokine genes in the peri-abutment fluid correlated positively with the detection of aerobes, anaerobes and Staphylococcus species, as well as with high Holger scores. Conclusion: This study provides unprecedented molecular information on the biological processes of BAHS. Despite being apparently healed, the peri-abutment fluid harbours prolonged inflammatory activity in conjunction with the presence of different bacterial species. An electropolished abutment surface appears to be associated with stronger proinflammatory activity than that with a machined surface. The analysis of the peri-abutment fluid deserves further verification as a non-invasive sampling and diagnostic procedure of BAHS.
  •  
2.
  • Ortiz Catalan, Max Jair, 1982, et al. (author)
  • Patterned Stimulation of Peripheral Nerves Produces Natural Sensations With Regards to Location but Not Quality
  • 2019
  • In: IEEE Transactions on Medical Robotics and Bionics. - 2576-3202. ; 1:3, s. 199-203
  • Journal article (peer-reviewed)abstract
    • Sensory feedback is crucial for dexterous manipulation and sense of ownership. Electrical stimulation of severed afferent fibers due to an amputation elicits referred sensations in the missing limb. However, these sensations are commonly reported with a concurrent “electric” or “tingling” character (paresthesia). In this paper, we examined the effect of modulating different pulse parameters on the quality of perceived sensations. Three subjects with above-elbow amputation were implanted with cuff electrodes and stimulated with a train of pulses modulated in either amplitude, width, or frequency (“patterned stimulation”). Pulses were shaped using a slower carrier wave or via quasi-random generation. Subjects were asked to evaluate the natural quality of the resulting sensations using a numeric rating scale. We found that the location of the percepts was distally referred and somatotopically congruent, but their quality remained largely perceived as artificial despite employing patterned modulation. Sensations perceived as arising from the missing limb are intuitive and natural with respect to their location and, therefore, useful for functional restoration. However, our results indicate that sensory transformation from paresthesia to natural qualia seems to require more than patterned stimulation.
  •  
3.
  • Capece, Sabrina, et al. (author)
  • A general strategy for obtaining biodegradable polymer shelled microbubbles as theranostic devices
  • 2013
  • In: Chemical Communications. - 1359-7345 .- 1364-548X. ; 49:51, s. 5763-5765
  • Journal article (peer-reviewed)abstract
    • Fabrication of multifunctional ultrasound contrast agents (UCAs) has been recently addressed by several research groups. A versatile strategy for the synthesis of UCA precursors in the form of biodegradable vesicles with a biocompatible crosslinked polymer shell is described. Upon ultrasound irradiation, acoustic droplet vaporization transforms such particles into microbubbles behaving as UCAs. This proof of concept entails the features of a potential theranostic microdevice.
  •  
4.
  • Bondesson, Johan, 1991, et al. (author)
  • Definition of Tubular Anatomic Structures from Arbitrary Stereo Lithographic Surface
  • 2017
  • In: Initiative Seminar Engineering Health, 8-9 November 2017, Chalmers.
  • Conference paper (other academic/artistic)abstract
    • An accurate description of anatomies and dynamics of vessels is crucial to understand their characteristics and improve surgical techniques, thus it is the basis, in addition to surgeon experience, on which stent design and operation procedures rely. The process of producing this description is user intensive, and recent improvement in image processing of medical3D imaging allows for a more automated workflow. However, there is a need to bridge the gap from a processed geometry to a robust mathematical computational grid. By sequentially segmenting a tubular anatomic structure, here defined by a stereo lithographic (STL) surface, an initial centerline is formed by connecting centroids of orthogonal cross-sectional contours along the length of the structure. Relying on the initial centerline, a set of non-overlapping 2D cross sectional contours are defined along the centerline, a centerline which is updated after the 2D contours are produced. After a second iteration of producing 2D contours and updating the centerline, a full description of the structure is created. Our method for describing vessel geometry shows good coherence to existing method. The main advantages of our method include the possibility of having arbitrary triangulated STL surface input, automated centerline definition, safety against intersecting cross-sectional contours and automatic clean-up of local kinks and wrinkles.
  •  
5.
  • Enejder, Annika, 1969, et al. (author)
  • SHG Imaging for Tissue Engineering Applications
  • 2016
  • In: Second Harmonic Generation Imaging. - : CRC Press. - 9781439849156 - 9781439849149 ; , s. 409-426
  • Book chapter (other academic/artistic)abstract
    • Treatment of lost tissue oen relies on transplantations, either of donor or of autologous tissue. Both alternatives have limitations; there is for example a limited supply of donor transplants, which also require immunosuppression therapy with possible side eects. Transplanted autologous tissue may lack some of the functions of the original tissue and the procedure may also introduce complications at the donor site. In some cases, articial substitutes manufactured from nonbiological materials can be used, for example, synthetic polymer blood vessels or joint replacement prostheses. However, these replacements have drawbacks such as risk for infections, limited material durability, and lack of mechanisms for repair, growth, and remodeling. For these reasons, development of advanced articial tissue constructs with adaptive capabilities is desirable.
  •  
6.
  •  
7.
  • Grishenkov, Dmitry, 1983-, et al. (author)
  • In search of the optimal ultrasound heart perfusion imaging platform
  • 2015
  • In: Journal of ultrasound in medicine. - : Wiley. - 0278-4297 .- 1550-9613. ; 34:9, s. 1599-1605
  • Journal article (peer-reviewed)abstract
    • ObjectiveQuantification of the myocardial perfusion by contrast echocardiography (CEC) remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled.MethodsTo contribute towards an improvement, we developed a CEC perfusion imaging platform based on isolated rat heart coupled to the ultrasound scanner. Perfusion was assessed using three different types of contrast agent: dextran-based Promiten®, phospholipid-shelled SonoVue®, and polymer-shelled MB-pH5-RT. The myocardial video-intensity was monitored over time from contrast administration to peak and two characteristic constants were calculated using exponential fit (A representing capillary volume and b representing inflow velocity).ResultsAcquired experimental evidence demonstrates that the application of all three types of contrast agent allow ultrasonic estimation of myocardial perfusion in the isolated rat heart. Video-intensity maps show that an increase in contrast concentration increases the late plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to Axb, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by the flowmeter attached to the aortic cannula.ConclusionsThe described CEC perfusion imaging platform holds promise for standardized evaluation and optimization of ultrasound contrast perfusion imaging where real time inflow curves at low acoustic power semi-quantitatively reflect coronary flow.
  •  
8.
  • Isaksson-Daun, Johan (author)
  • A Sound Approach Toward a Mobility Aid for Blind and Low-Vision Individuals
  • 2023
  • Doctoral thesis (other academic/artistic)abstract
    • Reduced independent mobility of blind and low-vision individuals (BLVIs) cause considerable societal cost, burden on relatives, and reduced quality of life for the individuals, including increased anxiety, depression symptoms, need of assistance, risk of falls, and mortality. Despite the numerous electronic travel aids proposed since at least the 1940’s, along with ever-advancing technology, the mobility issues persist. A substantial reason for this is likely several and severe shortcomings of the field, both in regards to aid design and evaluation.In this work, these shortcomings are addressed with a generic design model called Desire of Use (DoU), which describes the desire of a given user to use an aid for a given activity. It is then applied on mobility of BLVIs (DoU-MoB), to systematically illuminate and structure possibly all related aspects that such an aid needs to aptly deal with, in order for it to become an adequate aid for the objective. These aspects can then both guide user-centered design as well as choice of test methods and measures.One such measure is then demonstrated in the Desire of Use Questionnaire for Mobility of Blind and Low-Vision Individuals (DoUQ-MoB), an aid-agnostic and comprehensive patient-reported outcome measure. The question construction originates from the DoU-MoB to ensure an encompassing focus on mobility of BLVIs, something that has been missing in the field. Since it is aid-agnostic it facilitates aid comparison, which it also actively promotes. To support the reliability of the DoUQ-MoB, it utilizes the best known practices of questionnaire design and has been validated once with eight orientation and mobility professionals, and six BLVIs. Based on this, the questionnaire has also been revised once.To allow for relevant and reproducible methodology, another tool presented herein is a portable virtual reality (VR) system called the Parrot-VR. It uses a hybrid control scheme of absolute rotation by tracking the user’s head in reality, affording intuitive turning; and relative movement where simple button presses on a controller moves the virtual avatar forward and backward, allowing for large-scale traversal while not walking physically. VR provides excellent reproducibility, making various aggregate movement analysis feasible, while it is also inherently safe. Meanwhile, the portability of the system facilitates testing near the participants, substantially increasing the number of potential blind and low-vision recruits for user tests.The thesis also gives a short account on the state of long-term testing in the field; it being short is mainly due to that there is not much to report. It then provides an initial investigation into possible outcome measures for such tests by taking instruments in use by Swedish orientation and mobility professionals as a starting point. Two of these are also piloted in an initial single-session trial with 19 BLVIs, and could plausibly be used for long-term tests after further evaluation.Finally, a discussion is presented regarding the Audomni project — the development of a primary mobility aid for BLVIs. Audomni is a visuo-auditory sensory supplementation device, which aims to take visual information and translate it to sound. A wide field-of-view, 3D-depth camera records the environment, which is then transformed to audio through the sonification algorithms of Audomni, and finally presented in a pair of open-ear headphones that do not block out environmental sounds. The design of Audomni leverages the DoU-MoB to ensure user-centric development and evaluation, in the aim of reaching an aid with such form and function that it grants the users better mobility, while the users still want to use it.Audomni has been evaluated with user tests twice, once in pilot tests with two BLVIs, and once in VR with a heterogenous set of 19 BLVIs, utilizing the Parrot-VR and the DoUQ-MoB. 76 % of responders (13 / 17) answered that it was very or extremely likely that they would want use Audomni along with their current aid. This might be the first result in the field demonstrating a majority of blind and low-vision participants reporting that they actually want to use a new electronic travel aid. This shows promise that eventual long-term tests will demonstrate an increased mobility of blind and low-vision users — the overarching project aim. Such results would ultimately mean that Audomni can become an aid that alleviates societal cost, reduces burden on relatives, and improves users’ quality of life and independence.
  •  
9.
  • Kothapalli, Veera Venkata Satya Naray, 1985-, et al. (author)
  • Unique pumping-out fracturing mechanism of a polymer-shelled contrast agent : An acoustic characterization and optical visualization
  • 2014
  • In: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 62:3, s. 451-462
  • Journal article (peer-reviewed)abstract
    • This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.
  •  
10.
  • Márquez, Juan Carlos, et al. (author)
  • Textrode functional straps for bioimpedance measurements-experimental results for body composition analysis
  • 2013
  • In: European Journal of Clinical Nutrition. - : Nature Publishing Group. - 0954-3007 .- 1476-5640. ; 67:Suppl 1, s. 22-27
  • Journal article (peer-reviewed)abstract
    • Background/Objectives:Functional garments for physiological sensing purposes have been used in several disciplines, that is, sports, firefighting, military and medicine. In most of the cases, textile electrodes (textrodes) embedded in the garment are used to monitor vital signs and other physiological measurements. Electrical bioimpedance (EBI) is a non-invasive and effective technology that can be used for the detection and supervision of different health conditions.EBI technology could make use of the advantages of garment integration; however, a successful implementation of EBI technology depends on the good performance of textrodes. The main drawback of textrodes is a deficient skin-electrode interface that produces a high degree of sensitivity to signal disturbances. This sensitivity can be reduced with a suitable selection of the electrode material and an intelligent and ergonomic garment design that ensures an effective skin-electrode contact area.Subjects/Methods:In this work, textrode functional straps for total right side EBI measurements for body composition are presented, and its measurement performance is compared against the use of Ag/AgCl electrodes. Shieldex sensor fabric and a tetra-polar electrode configuration using the ImpediMed spectrometer SFB7 in the frequency range of 3-500 kHz were used to obtain and analyse the impedance spectra and Cole and body composition parameters.Results:The results obtained show stable and reliable measurements; the slight differences obtained with the functional garment do not significantly affect the computation of Cole and body composition parameters.Conclusions:The use of a larger sensor area, a high conductive material and an appropriate design can compensate, to some degree, for the charge transfer deficiency of the skin-electrode interface.
  •  
11.
  • Martinez Avila, Hector, 1985 (author)
  • Biofabrication, Biomechanics and Biocompatibility of Nanocellulose-based Scaffolds for Auricular Cartilage Regeneration
  • 2015
  • Doctoral thesis (other academic/artistic)abstract
    • In about 2:10,000 births the external part of the ear, the auricle, is severely malformed or absent. Furthermore, tumors and trauma can cause defects to the auricle. For patients with dysplasia of the auricle, and especially for children, an inconspicuous outer appearance with life-like auricles is important for their psychological and emotional well being as well as their psycho-social development. Auricular reconstruction remains a great challenge due to the complexity of surgical reconstruction using rib cartilage. Despite the advances in stem cell technology and biomaterials, auricular cartilage tissue engineering (TE) is still in an early stage of development due to critical requirements demanding appropriate mechanical properties and shape stability of the tissue-engineered construct. This thesis has focused on developing patient-specific tissue-engineered auricles for one-step surgery using a novel biomaterial, bacterial nanocellulose (BNC), seeded with human nasoseptal chondrocytes (hNC) and bone marrow mononuclear cells (MNC).Biomechanical properties of human auricle cartilage were measured and used as a benchmark for tuning BNC properties. In order to meet the biomechanical requirements, a scaffold with bilayer architecture composed of a dense BNC support layer and a macroporous structure was designed. Firstly, the biocompatibility of the dense BNC layer was investigated, demonstrating a minimal foreign body response according to standards set forth in ISO 10993. Secondly, different methods to create macroporous BNC scaffolds were studied and the redifferentiation capacity of hNCs was evaluated in vitro; revealing that macroporous BNC scaffolds support cell ingrowth, proliferation and neocartilage formation. The bilayer BNC scaffold was biofabricated and tested for endotoxins and cytotoxicity before evaluating in long-term 3D culture, and subsequently in vivo for eight weeks—in an immunocompromised animal model. The results demonstrated that the non-pyrogenic and non- cytotoxic bilayer BNC scaffold offers a good mechanical stability and maintains a structural integrity, while providing a porous 3D environment that is suitable for hNCs and MNCs to produce neocartilage, in vitro and in vivo. Furthermore, patient-specific auricular BNC scaffolds with bilayer architecture were biofabricated and seeded with autologous rabbit auricular chondrocytes (rAC) for implantation in an immunocompetent rabbit model for six weeks. The results demonstrated the shape stability of the rAC-seeded scaffolds and neocartilage depositions in the immunocompetent autologous grafts. 3D bioprinting was also evaluated for biofabrication of patient-specific, chondrocyte-laden auricular constructs using a bioink composed of nanofibrillated cellulose and alginate. Bioprinted auricular constructs showed an excellent shape and size stability after in vitro culture. Moreover, this bioink supports redifferentiation of hNCs while offering excellent printability, making this a promising approach for auricular cartilage TE. Furthermore, the use of bioreactors is essential for the development of tissue-engineered cartilage in vitro. Thus, a compression bioreactor was utilized to apply dynamic mechanical stimulation to cell-seeded constructs as a means to enhance production of extracellular matrix in vitro.In this work, a potential clinical therapy for auricular reconstruction using tissue-engineered auricles is demonstrated; where BNC is proposed as a promising non-degradable biomaterial with good chemical and mechanical stability for auricular cartilage TE. Although the primary focus of this thesis is on auricular reconstruction, the methods developed are also applicable in the regeneration of other cartilage tissues such as those found in the nose, trachea, spine and articular joints.
  •  
12.
  • Pettersen, Emily, 1996, et al. (author)
  • Enhancing osteoblast survival through pulsed electrical stimulation and implications for osseointegration
  • 2021
  • In: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 11:1
  • Journal article (peer-reviewed)abstract
    • Electrical stimulation has been suggested as a means for promoting the direct structural and functional bonding of bone tissue to an artificial implant, known as osseointegration. Previous work has investigated the impact of electrical stimulation in different models, both in vitro and in vivo, using various electrode configurations for inducing an electric field with a wide range of stimulation parameters. However, there is no consensus on optimal electrode configuration nor stimulation parameters. Here, we investigated a novel approach of delivering electrical stimulation to a titanium implant using parameters clinically tested in a different application, namely peripheral nerve stimulation. We propose an in vitro model comprising of Ti6Al4V implants precultured with MC3T3-E1 preosteoblasts, stimulated for 72 h at two different pulse amplitudes (10 mu A and 20 mu A) and at two different frequencies (50 Hz and 100 Hz). We found that asymmetric charge-balanced pulsed electrical stimulation improved cell survival and collagen production in a dose-dependent manner. Our findings suggest that pulsed electrical stimulation with characteristics similar to peripheral nerve stimulation has the potential to improve cell survival and may provide a promising approach to improve peri-implant bone healing, particularly to neuromusculoskeletal interfaces in which implanted electrodes are readily available.
  •  
13.
  • Andersson, Helene, 1983, et al. (author)
  • Effects of molecular weight on permeability and microstructure of mixed ethyl-hydroxypropyl-cellulose films
  • 2013
  • In: European Journal of Pharmaceutical Sciences. - : Elsevier BV. - 0928-0987 .- 1879-0720. ; 48:1-2, s. 240-248
  • Journal article (peer-reviewed)abstract
    • Films of ethyl cellulose (EC) and water-soluble hydroxypropyl cellulose (HPC) can be used for extended release coatings in oral formulations. The permeability and microstructure of free EC/HPC films with 30% w/w HPC were studied to investigate effects of EC molecular weight. Phase separation during film spraying and subsequent HPC leaching after immersion in aqueous media cause pore formation in such films. It was found that sprayed films were porous throughout the bulk of the films after water immersion. The molecular weight affected HPC leaching, pore morphology and film permeability; increasing the molecular weight resulted in decreasing permeability. A model to distinguish the major factors contributing to diffusion retardation in porous films showed that the trend in permeability was determined predominantly by factors associated with the geometry and arrangement of pores, independent of the diffusing species. The film with the highest molecular weight did, however, show an additional contribution from pore wall/permeant interactions. In addition, rapid drying and increasing molecular weight resulted in smaller pores, which suggest that phase separation kinetics affects the final microstructure of EC/HPC films. Thus, the molecular weight influences the microstructural features of pores, which are crucial for mass transport in EC/HPC films.
  •  
14.
  • Augustine, Robin (author)
  • Biocompatibility study of hydroxyapatite-chitosan composite for medical applications at microwave frequencies
  • 2008
  • In: Microwave and optical technology letters (Print). - 0895-2477 .- 1098-2760. ; 50:11, s. 2931-2934
  • Journal article (peer-reviewed)abstract
    • Hydroxyapatite (HAp, Ca10(PO4)6(OH)2) bioceramic and chitosan (poly [(β-1-4) d-glucosamine]) biopolymer show good biocompatibility in vivo. They have biological origin and show excellent interactions with microwave. Microwave study of HAp made using different drying techniques and their composites with chitosan in the ISM band is presented. Pastes are made using HAp and chitosan with different ratios of mixing. The dielectric properties of this composites match with that of human fat, collagen tissues. Some of the compositions exhibit dielectric property close to that of natural bone. This makes them more biocompatible and better substitutes for natural bone. Thus composite bioceramics can be considered as phantom model constituents for imaging purposes.
  •  
15.
  • Palmquist, Anders, 1977, et al. (author)
  • Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants
  • 2023
  • In: Acta Biomaterialia. - : Elsevier BV. - 1742-7061 .- 1878-7568. ; 156, s. 125-145
  • Research review (peer-reviewed)abstract
    • The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. Statement of significance: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient's age and disease status.
  •  
16.
  • Pirozzi, Ileana, et al. (author)
  • Circulatory Support : Artificial Muscles for the Future of Cardiovascular Assist Devices
  • 2023
  • In: Advanced Materials. - : Wiley. - 0935-9648 .- 1521-4095.
  • Journal article (peer-reviewed)abstract
    • Artificial muscles enable the design of soft implantable devices which are poised to transform the way we mechanically support the heart today. Heart failure is a prevalent and deadly disease, which is treated with the implantation of rotary blood pumps as the only alternative to heart transplantation. The clinically used mechanical devices are associated with severe adverse events, which are reflected here in a comprehensive list of critical requirements for soft active devices of the future: low power, no blood contact, pulsatile support, physiological responsiveness, high cycle life, and less-invasive implantation. In this review, we investigate and critically evaluate prior art in artificial muscles for their applicability in the short and long term. We highlight the main challenges regarding the effectiveness, controllability, and implantability of recently proposed actuators and explore future perspectives for attachment, physiological responsiveness, durability, and biodegradability as well as equitable design considerations.
  •  
17.
  • Sun, Fengzhen, et al. (author)
  • Mechanical characteristics of nanocellulose-PEG bionanocomposite wound dressings in wet conditions
  • 2017
  • In: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier BV. - 1751-6161 .- 1878-0180. ; 69, s. 377-384
  • Journal article (peer-reviewed)abstract
    • Wood nanocellulose has been proposed for wound dressing applications partly based on its capability to form translucent films with good liquid absorption capabilities. Such properties are adequate for non-healing and chronic wounds where adequate management of exudates is a requirement. In addition, the translucency will allow to follow the wound development without the necessity to remove the dressing from the wound. Understanding the mechanical properties of nanocellulose films and dressings are also most important for tailoring optimizing wound dressing structures with adequate strength, conformability, porosity and exudate management. Mechanical properties are usually assessed in standard conditions (50% relative humidity, RH), which is not relevant in a wound management situation. In this study we have assessed the mechanical properties of three nanocellulose grades varying in the degree of nanofibrillation. The effect of nanofibrillation and of polyethylene glycol (PEG) addition, on the tensile strength, elongation and elastic modulus were assessed after 24 h in water and in phosphate-buffered saline (PBS). The results reveal the behavior of the nanocellulose dressings after wetting and shed light into the development of mechanical properties in environments, which are relevant from a wound management point of view.
  •  
18.
  • Clemente, Francesco, et al. (author)
  • Non-Invasive, Temporally Discrete Feedback of Object Contact and Release Improves Grasp Control of Closed-Loop Myoelectric Transradial Prostheses
  • 2016
  • In: IEEE transactions on neural systems and rehabilitation engineering. - 1534-4320 .- 1558-0210. ; 24:12, s. 1314-1322
  • Journal article (peer-reviewed)abstract
    • Human grasping and manipulation control critically depends on tactile feedback. Without this feedback, the ability for fine control of a prosthesis is limited in upper limb amputees. Although various approaches have been investigated in the past, at present there is no commercially available device able to restore tactile feedback in upper limb amputees. Based on the Discrete Event-driven Sensory feedback Control (DESC) policy we present a device able to deliver short-lasting vibrotactile feedback to transradial amputees using commercially available myoelectric hands. The device (DESC-glove) comprises sensorized thimbles to be placed on the prosthesis digits, a battery-powered electronic board, and vibrating units embedded in an arm-cuff being transiently activated when the prosthesis makes and breaks contact with objects. The consequences of using the DESC-glove were evaluated in a longitudinal study. Five transradial amputees were equipped with the device for onemonth at home. Through a simple test proposed here for the first time-the virtual eggs test-we demonstrate the effectiveness of the device for prosthetic control in daily life conditions. In the future the device could be easily exploited as an add-on to complement myoelectric prostheses or even embedded in prosthetic sockets to enhance their control by upper limb amputees.
  •  
19.
  • Grishenkov, Dmitry, 1983-, et al. (author)
  • Ultrasound contrast agent loaded with nitric oxide as a theranostic microdevice : Theranostic contrast agent loaded with nitric oxide
  • 2015
  • In: Drug Design, Development and Therapy. - 1177-8881. ; 9, s. 2409-2419
  • Journal article (peer-reviewed)abstract
    • The current study describes novel multifunctional polymer-shelled microbubbles (MBs) loaded with nitric oxide (NO) for integrated therapeutic and diagnostic applications, i.e. theranostics, of myocardial ischemia. We used gas filled MBs with an average diameter of 4 µm stabilized by a biocompatible shell of poly(vinyl)alcohol. In vitro acoustic tests showed a sufficient enhancement of the backscattered power (20 dB) acquired from the MBs suspension. The values of attenuation coefficient (0.8 dB/cm MHz) and phase velocities (1517 m/s) were comparable to those reported for the soft tissue. Moreover, polymer MBs demonstrate increased stability compared to clinically approved contrast agents with fracture threshold of about 900 kPa. In vitro chemiluminescence measurements demonstrated that dry powder of NO-loaded MBs releases its gas content in about 2 hours following an exponential decay profile with an exponential time constant equal 36 min. The application of high power ultrasound pulse (MI=1.2) on the MBs resuspended in saline decreases the exponential time constant from 55 to 4 min in air saturated solution and from 17 to 10 min in degased solution. Thus, ultrasound-triggered release of NO is achieved. Cytotoxicity tests indicate that phagocytosis of the MBs by macrophages starts within 6 to 8 hours. This is suitable time for initial diagnostics, treatment and monitoring of the therapeutic effect using single injection of the proposed multifunctional MBs.
  •  
20.
  • Klintström, Benjamin, et al. (author)
  • Photon-counting detector CT and energy-integrating detector CT for trabecular bone microstructure analysis of cubic specimens from human radius
  • 2022
  • In: European radiology experimental. - : Springer Nature. - 2509-9280. ; 6:1
  • Journal article (peer-reviewed)abstract
    • Background As bone microstructure is known to impact bone strength, the aim of this in vitro study was to evaluate if the emerging photon-counting detector computed tomography (PCD-CT) technique may be used for measurements of trabecular bone structures like thickness, separation, nodes, spacing and bone volume fraction. Methods Fourteen cubic sections of human radius were scanned with two multislice CT devices, one PCD-CT and one energy-integrating detector CT (EID-CT), using micro-CT as a reference standard. The protocols for PCD-CT and EID-CT were those recommended for inner- and middle-ear structures, although at higher mAs values: PCD-CT at 450 mAs and EID-CT at 600 (dose equivalent to PCD-CT) and 1000 mAs. Average measurements of the five bone parameters as well as dispersion measurements of thickness, separation and spacing were calculated using a three-dimensional automated region growing (ARG) algorithm. Spearman correlations with micro-CT were computed. Results Correlations with micro-CT, for PCD-CT and EID-CT, ranged from 0.64 to 0.98 for all parameters except for dispersion of thickness, which did not show a significant correlation (p = 0.078 to 0.892). PCD-CT had seven of the eight parameters with correlations rho > 0.7 and three rho > 0.9. The dose-equivalent EID-CT instead had four parameters with correlations rho > 0.7 and only one rho > 0.9. Conclusions In this in vitro study of radius specimens, strong correlations were found between trabecular bone structure parameters computed from PCD-CT data when compared to micro-CT. This suggests that PCD-CT might be useful for analysing bone microstructure in the peripheral human skeleton.
  •  
21.
  • Marques, Filipe, et al. (author)
  • Absorbable cyst brushes
  • 2023
  • In: Biomedical microdevices (Print). - : Springer Nature. - 1387-2176 .- 1572-8781. ; 25:3
  • Journal article (peer-reviewed)abstract
    • Cytobrushes are used for low-invasive sample collection and screening in multiple diseases, with a significant impact on early detection, prevention, and diagnosis. This study focuses on improving the safety of cell brushing in hard-to-reach locations by exploring brush construction from absorbable materials. We investigated the efficacy of loop brushes made of absorbable suture wires of Chirlac, Chirasorb, Monocryl, PDS II, Vicryl Rapid, Glycolon, and Catgut during their operation in conjunction with fine-needle aspiration in an artificial cyst model. PDS II brushes demonstrated the highest efficiency, while Monocryl and Catgut also provided a significant brushing effect. Efficient brushes portrayed higher flexural rigidity than their counterparts, and their efficiency was inversely proportional to their plastic deformation by the needle. Our results open avenues for safer cell biopsies in hard-to-reach locations by utilizing brushes composed of absorbable materials.
  •  
22.
  • Marquez Ruiz, Juan Carlos (author)
  • Sensor-Based Garments that Enable the Use of Bioimpedance Technology : Towards PersonalizedHealthcare Monitoring.
  • 2013
  • Doctoral thesis (other academic/artistic)abstract
    • Functional garments for physiological sensing purposes have been utilized in several disciplinesi.e. sports, firefighting, military and medical. In most of the cases textile electrodes (Textrodes)embedded in the garment are employed to monitor vital signs and other physiologicalmeasurements. Electrical Bioimpedance (EBI) is a non-invasive and effective technology that canbe used for detection and supervision of different health conditions. In some specific applicationssuch as body composition assessment EBIS has shown encouraging results proving good degreeof effectiveness and reliability. In a similar way Impedance Cardiography (ICG) is anothermodality of EBI primarily concerned with the determination of Stroke Volume SV, indices ofcontractility, and other aspects of hemodynamics.EBI technology in the previously mentioned modalities can benefit from a integration with agarment; however, a successful implementation of EBI technology depends on the goodperformance of textile electrodes. The main weakness of Textrodes is a deficient skin-electrodeinterface which produces a high degree of sensitivity to signal disturbances. This sensitivity canbe reduced with a suitable selection of the electrode material and an intelligent and ergonomicgarment design that ensures an effective skin-electrode contact area.This research work studies the performance of textile electrodes and garments for EBIspectroscopy for Total Body Assessment and Transthoracic Electrical Bioimpedance (TEB) forcardio monitoring. Their performance is analyzed based on impedance spectra, estimation ofparameters, influence of electrode polarization impedance Zep and quality of the signals using asreference Ag/AgCl electrodes. The study includes the analysis of some characteristics of thetextile electrodes such as conductive material, skin-electrode contact area size and fabricconstruction.The results obtained in this research work present evidence that textile garments with a dry skinelectrodeinterface like the ones used in research produce reliable EBI measurements in bothmodalities: BIS for Total Body Assessment and TEB for Impedance Cardiography. Textiletechnology, if successfully integrated, may enable the utilization of EBI in both modalities andconsequently implementing wearable applications for home and personal health monitoring.
  •  
23.
  • Mürer, Fredrik K., et al. (author)
  • Quantifying the hydroxyapatite orientation near the ossification front in a piglet femoral condyle using X-ray diffraction tensor tomography
  • 2021
  • In: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 11:1
  • Journal article (peer-reviewed)abstract
    • While a detailed knowledge of the hierarchical structure and morphology of the extracellular matrix is considered crucial for understanding the physiological and mechanical properties of bone and cartilage, the orientation of collagen fibres and carbonated hydroxyapatite (HA) crystallites remains a debated topic. Conventional microscopy techniques for orientational imaging require destructive sample sectioning, which both precludes further studies of the intact sample and potentially changes the microstructure. In this work, we use X-ray diffraction tensor tomography to image non-destructively in 3D the HA orientation in a medial femoral condyle of a piglet. By exploiting the anisotropic HA diffraction signal, 3D maps showing systematic local variations of the HA crystallite orientation in the growing subchondral bone and in the adjacent mineralized growth cartilage are obtained. Orientation maps of HA crystallites over a large field of view (~ 3 × 3 × 3 mm3) close to the ossification (bone-growth) front are compared with high-resolution X-ray propagation phase-contrast computed tomography images. The HA crystallites are found to predominantly orient with their crystallite c-axis directed towards the ossification front. Distinct patterns of HA preferred orientation are found in the vicinity of cartilage canals protruding from the subchondral bone. The demonstrated ability of retrieving 3D orientation maps of bone-cartilage structures is expected to give a better understanding of the physiological properties of bones, including their propensity for bone-cartilage diseases.
  •  
24.
  •  
25.
  • Wu, Dan, 1990-, et al. (author)
  • Young’s modulus of trabecular bone at the tissue level : A review
  • 2018
  • In: Acta Biomaterialia. - : Elsevier BV. - 1742-7061 .- 1878-7568. ; 78, s. 1-12
  • Research review (peer-reviewed)abstract
    • The tissue-level Young’s modulus of trabecular bone is important for detailed mechanical analysis of bone and bone-implant mechanical interactions. However, the heterogeneity and small size of the trabecular struts complicate an accurate determination. Methods such as micro-mechanical testing of single trabeculae, ultrasonic testing, and nanoindentation have been used to estimate the trabecular Young’s modulus. This review summarizes and classifies the trabecular Young’s moduli reported in the literature. Information on species, anatomic site, and test condition of the samples has also been gathered. Advantages and disadvantages of the different methods together with recent developments are discussed, followed by some suggestions for potential improvement, for future work. In summary, this review provides a thorough introduction to the approaches used for determining trabecular Young’s modulus, highlights important considerations when applying these methods and summarizes the reported Young’s modulus for follow-up studies on trabecular properties.
  •  
26.
  • Eriksson, Siw, et al. (author)
  • Three-dimensional Fabrics as Medical Textiles
  • 2015
  • In: Advances in 3D Textiles. - : Woodhead Publishing Limited. - 9781782422143 - 9781782422198 ; , s. 305-340
  • Book chapter (other academic/artistic)abstract
    • The number of 3D textile applications in medicine is rapidly increasing as new technology and procedures are introduced in health care.  A first estimate of current medical applications of both general and 3D textiles is presented based on the medical devices classification system established by the US Food and Drug Administration. The textile specifics for these applications are covered from a textile technique perspective where the different 3D weaving as well as knitting, braiding and non-woven techniques are described and how their properties they can contribute in medical applications. In addition, emerging opportunities based on smart textiles as part of textile systems are described on a general level. The strong application areas of 3D medical textiles, i.e. wound management, vascular grafting and scaffolding for tissue engineering are covered in detail both from the medical and textiles perspective. Finally, some future lines of development are suggested and a short discussion on how new 3D textiles applications can be developed in close cooperation between the textile industry and the health care sector is presented.
  •  
27.
  •  
28.
  • Grishenkov, Dmitry, 1983-, et al. (author)
  • Ultrasound contrast agent loaded with nitric oxide as a theranostic microdevise for myocardial ischemia
  • 2013
  • In: European Heart Journal Cardiovascular Imaging.
  • Conference paper (peer-reviewed)abstract
    • Cardiovascular disease (CVD) accounts for 1/3 of total global deaths worldwide. The most widespread CVD is ischemic heart disease. It is the leading cause of death in both genders, equally diagnosed in developed and developing countries with mortality exponentially increasing with age. Efforts of healthcare system should be primary focused on prevention, timely detection, efficient differentiation and instant treatment of the disease.
  •  
29.
  •  
30.
  • Abdollahi Sani, Negar, et al. (author)
  • A ferroelectric polymer introduces addressability in electrophoretic display cells
  • 2019
  • In: FLEXIBLE AND PRINTED ELECTRONICS. - : IOP PUBLISHING LTD. - 2058-8585. ; 4:3
  • Journal article (peer-reviewed)abstract
    • During the last decades, tremendous efforts have been carried out to develop flexible electronics for a vast array of applications. Among all different applications investigated in this area, flexible displays have gained significant attention, being a vital part of large-area devices, portable systems and electronic labels etc electrophoretic (EP) ink displays have outstanding properties such as a superior optical switch contrast and low power consumption, besides being compatible with flexible electronics. However, the EP ink technology requires an active matrix-addressing scheme to enable exclusive addressing of individual pixels. EP ink pixels cannot be incorporated in low cost and easily manufactured passive matrix circuits due to the lack of threshold voltage and nonlinearity, necessities to provide addressability. Here, we suggest a simple method to introduce nonlinearity and threshold voltage in EP ink display cells in order to make them passively addressable. Our method exploits the nonlinearity of an organic ferroelectric capacitor that introduces passive addressability in display cells. The organic ferroelectric material poly(vinylidene fluoride-co-trifluoroethylene) (P(VDF-TrFE)) is here chosen because of its simple manufacturing protocol and good polarizability. We demonstrate that a nonlinear EP cell with bistable states can be produced by depositing a P(VDF-TrFE) film on the bottom electrode of the display cell. The P(VDF-TrFE) capacitor and the EP ink cell are separately characterized in order to match the surface charge at their respective interfaces and to achieve and optimize bistable operation of display pixels.
  •  
31.
  • Abdullah, Saad, et al. (author)
  • Comparing the Effectiveness of EMG and Electrical Impedance myography Measurements for Controlling Prosthetics
  • 2023
  • In: IEEE Int. Multidiscip. Conf. Eng. Technol., IMCET. - : Institute of Electrical and Electronics Engineers Inc.. - 9798350313826 ; , s. 189-193
  • Conference paper (peer-reviewed)abstract
    • In recent years, the field of prosthetics has made significant progress towards creating prosthetic devices that are more functional, comfortable, and user-friendly. However, achieving intuitive control over prosthetic hand movements remains a significant challenge, especially for individuals with limb loss who rely on prosthetics for independent daily activities. To address this challenge, researchers have explored the potential of non-invasive techniques as electromyography (EMG) for prosthetic control. This paper aims to investigate the potential of using EMG and the electrical impedance myography (EIMG) techniques jointly for the measurement of hand movements. The study involved recording and comparing EMG and EIMG signals from a cohort of healthy individuals. These signals were captured during four distinct hand gestures: opening and closing the hand, as well as extending and flexing it, under varying time conditions, allowing for categorization into low and high-intensity movements. Data collection employed the Open BCI and ZRPI devices. The analysis of these signal waveforms revealed compelling results. Brachioradialis activity in EMG 2 exhibited an increase during open hand (0.015mV) and extension hand (0.009mV in low and 0.013mV in high intensity) gestures, accompanied by increased EIMG activity (56mV and 52mV respectively). Additionally, close hand (0.0018mV in low and 0.05mV in high intensity) and flexion hand (0.0075 in low intensity and 0.002 in high intensity) gestures exhibited heightened flexor carpi ulnaris activity with raised EIMG activity (57mV and 45mV respectively). These results proved to be consistent, acceptable, and aligned with existing literature. The findings of this paper indicate that both EMG and EIMG techniques could be used together to control custom-made hand prosthetics, demonstrating a significant development that could lead to more intuitive and easier-to-control prosthetics. Also, the results obtained could be valuable to researchers and engineers working in the prosthetics field, as it provides insights into the potential of non-invasive techniques for prosthetic control.
  •  
32.
  • Acet, Ömür, et al. (author)
  • Inhibition of bacterial adhesion by epigallocatechin gallate attached polymeric membranes
  • 2023
  • In: Colloids and Surfaces B: Biointerfaces. - : Elsevier BV. - 0927-7765 .- 1873-4367. ; 221
  • Journal article (peer-reviewed)abstract
    • Microbial adhesion and formation of biofilms cause a serious problem in several areas including but not limited to food spoilage, industrial corrosion and nosocomial infections. These microbial biofilms pose a serious threat to human health since microbial communities in the biofilm matrix are protected with exopolymeric substances and difficult to eradicate with antibiotics. Hence, the prevention of microbial adhesion followed by biofilm formation is one of the promising strategies to prevent these consequences. The attachment of antimicrobial agents, coatings of nanomaterials and synthesis of hybrid materials are widely used approach to develop surfaces having potential to hinder bacterial adhesion and biofilm formation. In this study, epigallocatechin gallate (EGCG) is attached on p(HEMA-co-GMA) membranes to prevent the bacterial colonization. The attachment of EGCG to membranes was proved by Fourier-transform infrared spectroscopy (FT-IR). The synthesized membrane showed porous structure (SEM), and desirable swelling degree, which are ideal when it comes to the application in biotechnology and biomedicine. Furthermore, EGCG attached membrane showed significant potential to prevent the microbial colonization on the surface. The obtained results suggest that EGCG attached polymer could be used as an alternative approach to prevent the microbial colonization on the biomedical surfaces, food processing equipment as well as development of microbial resistant food packaging systems.
  •  
33.
  • Ahkami, Bahareh, 1994, et al. (author)
  • Extra-neural signals from severed nerves enable intrinsic hand movements in transhumeral amputations
  • 2022
  • In: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 12:1
  • Journal article (peer-reviewed)abstract
    • Robotic prostheses controlled by myoelectric signals can restore limited but important hand function in individuals with upper limb amputation. The lack of individual finger control highlights the yet insurmountable gap to fully replacing a biological hand. Implanted electrodes around severed nerves have been used to elicit sensations perceived as arising from the missing limb, but using such extra-neural electrodes to record motor signals that allow for the decoding of phantom movements has remained elusive. Here, we showed the feasibility of using signals from non-penetrating neural electrodes to decode intrinsic hand and finger movements in individuals with above-elbow amputations. We found that information recorded with extra-neural electrodes alone was enough to decode phantom hand and individual finger movements, and as expected, the addition of myoelectric signals reduced classification errors both in offline and in real-time decoding.
  •  
34.
  • Ajalloueian, Fatemeh, et al. (author)
  • One-Stage Tissue Engineering of Bladder Wall Patches for an Easy-To-Use Approach at the Surgical Table
  • 2013
  • In: Tissue Engineering. Part C, Methods. - : Mary Ann Liebert Inc. - 1937-3384 .- 1937-3392. ; 19:9, s. 688-696
  • Journal article (peer-reviewed)abstract
    • We present a method for producing a cell-scaffold hybrid construct at the bedside. The construct is composed of plastic-compressed collagen together with a poly(e-caprolactone) (PCL)-knitted mesh that yields an integrated, natural-synthetic scaffold. This construct was evaluated by seeding of minced bladder mucosa, followed by proliferation in vitro. High mechanical strength in combination with a biological environment suitable for tissue growth was achieved through the creation of a hybrid construct that showed an increased tensile strength (17.9 +/- 2.6 MPa) when compared to plastic-compressed collagen (0.6 +/- 0.12 MPa). Intimate contact between the collagen and the PCL fabric was required to ensure integrity without delamination of the construct. This contact was achieved by surface alkaline hydrolysis of the PCL, followed by adsorption of poly(vinyl) alcohol. The improvement in hydrophilicity of the PCL-knitted mesh was confirmed through water contact angle measurements, and penetration of the collagen into the mesh was evaluated by scanning electron microscopy (SEM). Particles of minced bladder mucosa tissue were seeded onto this scaffold, and the proliferation was followed for 6 weeks in vitro. Results obtained from phase contrast microscopy, SEM, and histological staining indicated that cells migrated from the minced tissue particles and reorganized on the scaffold. Cells were viable and proliferative, with morphological features characteristic of urothelial cells. Proliferation reached the point at which a multilayer with a resemblance to stratified urothelium was achieved. This successful method could potentially be used for in vivo applications in reconstructive urology as an engineered autologous tissue transplant without the requirement for in vitro culture before transplantation.
  •  
35.
  •  
36.
  • Ajaxon, Ingrid, 1983- (author)
  • Can Bone Void Fillers Carry Load? : Behaviour of Calcium Phosphate Cements Under Different Loading Scenarios
  • 2017
  • Doctoral thesis (other academic/artistic)abstract
    • Calcium phosphate cements (CPCs) are used as bone void fillers and as complements to hardware in fracture fixation. The aim of this thesis was to investigate the possibilities and limitations of the CPCs’ mechanical properties, and find out if these ceramic bone cements can carry application-specific loads, alone or as part of a construct. Recently developed experimental brushite and apatite cements were found to have a significantly higher strength in compression, tension and flexion compared to the commercially available CPCs chronOS™ Inject and Norian® SRS®. By using a high-resolution measurement technique the elastic moduli of the CPCs were determined and found to be at least twice as high compared to earlier measurements, and closer to cortical bone than trabecular bone. Using the same method, Poisson's ratio for pure CPCs was determined for the first time. A non-destructive porosity measurement method for wet brushite cements was developed, and subsequently used to study the porosity increase during in vitro degradation. The compressive strength of the experimental brushite cement was still higher than that of trabecular bone after 25 weeks of degradation, showing that the cement can carry high loads over a time span sufficiently long for a fracture to heal. This thesis also presents the first ever fatigue results for acidic CPCs, and confirms the importance of testing the materials under cyclic loading as the cements may fail at stress levels much lower than the material’s quasi-static compressive strength. A decrease in fatigue life was found for brushite cements containing higher amounts of monetite. Increasing porosity and testing in a physiological buffer solution (PBS), rather than air, also decreased the fatigue life. However, the experimental brushite cement had a high probability of surviving loads found in the spine when tested in PBS, which has previously never been accomplished for acidic CPCs. In conclusion, available brushite cements may be able to carry the load alone in scenarios where the cortical shell is intact, the loading is mainly compressive, and the expected maximum stress is below 10 MPa. Under such circumstances this CPC may be the preferred choice over less biocompatible and non-degradable materials.
  •  
37.
  •  
38.
  •  
39.
  • Ajaxon, Ingrid, et al. (author)
  • Compressive fatigue properties of an acidic calcium phosphate cement—effect of phase composition
  • 2017
  • In: Journal of materials science. Materials in medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 28:3
  • Journal article (peer-reviewed)abstract
    • Calcium phosphate cements (CPCs) are synthetic bone grafting materials that can be used in fracture stabilization and to fill bone voids after, e.g., bone tumour excision. Currently there are several calcium phosphate-based formulations available, but their use is partly limited by a lack of knowledge of their mechanical properties, in particular their resistance to mechanical loading over longer periods of time. Furthermore, depending on, e.g., setting conditions, the end product of acidic CPCs may be mainly brushite or monetite, which have been found to behave differently under quasi-static loading. The objectives of this study were to evaluate the compressive fatigue properties of acidic CPCs, as well as the effect of phase composition on these properties. Hence, brushite cements stored for different lengths of time and with different amounts of monetite were investigated under quasi-static and dynamic compression. Both storage and brushite-to-monetite phase transformation was found to have a pronounced effect both on quasi-static compressive strength and fatigue performance of the cements, whereby a substantial phase transformation gave rise to a lower mechanical resistance. The brushite cements investigated in this study had the potential to survive 5 million cycles at a maximum compressive stress of 13 MPa. Given the limited amount of published data on fatigue properties of CPCs, this study provides an important insight into the compressive fatigue behaviour of such materials. 
  •  
40.
  •  
41.
  • Ajaxon, Ingrid, et al. (author)
  • Elastic properties and strain-to-crack-initation of calcium phosphate bone cements : Revelations of a high-resolution measurement technique
  • 2017
  • In: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier BV. - 1751-6161 .- 1878-0180. ; 74, s. 428-437
  • Journal article (peer-reviewed)abstract
    • Calcium phosphate cements (CPCs) should ideally have mechanical properties similar to those of the bone tissue the material is used to replace or repair. Usually, the compressive strength of the CPCs is reported and, more rarely, the elastic modulus. Conversely, scarce or no data are available on Poisson's ratio and strain-to-crack-initiation. This is unfortunate, as data on the elastic response is key to, e.g., numerical model accuracy. In this study, the compressive behaviour of brushite, monetite and apatite cements was fully characterised. Measurement of the surface strains was done using a digital image correlation (DIC) technique, and compared to results obtained with the commonly used built-in displacement measurement of the materials testers. The collected data showed that the use of fixed compression platens, as opposed to spherically seated ones, may in some cases underestimate the compressive strength by up to 40%. Also, the built-in measurements may underestimate the elastic modulus by up to 62% as compared to DIC measurements. Using DIC, the brushite cement was found to be much stiffer (24.3 ± 2.3 GPa) than the apatite (13.5 ± 1.6 GPa) and monetite (7.1 ± 1.0 GPa) cements, and elastic moduli were inversely related to the porosity of the materials. Poisson's ratio was determined to be 0.26 ± 0.02 for brushite, 0.21 ± 0.02 for apatite and 0.20 ± 0.03 for monetite. All investigated CPCs showed low strain-to-crack-initiation (0.17–0.19%). In summary, the elastic modulus of CPCs is substantially higher than previously reported and it is concluded that an accurate procedure is a prerequisite in order to properly compare the mechanical properties of different CPC formulations. It is recommended to use spherically seated platens and measuring the strain at a relevant resolution and on the specimen surface.
  •  
42.
  • Ajaxon, Ingrid, et al. (author)
  • Evaluation of a porosity measurement method for wet calcium phosphate cements
  • 2015
  • In: Journal of biomaterials applications. - : Sage Publications. - 0885-3282 .- 1530-8022. ; 30:5, s. 526-536
  • Journal article (peer-reviewed)abstract
    • The porosity of a calcium phosphate cement is a key parameter as it affects several important properties of the cement. However, a successful, non-destructive porosity measurement method that does not include drying has not yet been reported for calcium phosphate cements. The aim of this study was to evaluate isopropanol solvent exchange as such a method. Two different types of calcium phosphate cements were used, one basic (hydroxyapatite) and one acidic (brushite). The cements were allowed to set in an aqueous environment and then immersed in isopropanol and stored under three different conditions: at room temperature, at room temperature under vacuum (300 mbar) or at 37?C. The specimen mass was monitored regularly. Solvent exchange took much longer time to reach steady state in hydroxyapatite cements compared to brushite cements, 350 and 18 h, respectively. Furthermore, the immersion affected the quasi-static compressive strength of the hydroxyapatite cements. However, the strength and phase composition of the brushite cements were not affected by isopropanol immersion, suggesting that isopropanol solvent exchange can be used for brushite calcium phosphate cements. The main advantages with this method are that it is non-destructive, fast, easy and the porosity can be evaluated while the cements remain wet, allowing for further analysis on the same specimen. 
  •  
43.
  • Ajaxon, Ingrid, et al. (author)
  • Fatigue performance of a high-strength, degradable calcium phosphate bone cement
  • 2018
  • In: Journal of The Mechanical Behavior of Biomedical Materials. - : ELSEVIER SCIENCE BV. - 1751-6161 .- 1878-0180. ; 79, s. 46-52
  • Journal article (peer-reviewed)abstract
    • Calcium phosphate cements (CPCs) are clinically used as injectable materials to fill bone voids and to improve hardware fixation in fracture surgery. In vivo they are dynamically loaded; nonetheless little is known about their fatigue properties. The aim of this study was to, for the first time, investigate the fatigue performance of a high strength, degradable (brushitic) CPC, and also evaluate the effect of cement porosity (by varying the liquid to powder ratio, L/P) and the environment (air at room temperature or in a phosphate buffered saline solution, PBS, at 37 degrees C) on the fatigue life. At a maximum compressive stress level of 15 MPa, the cements prepared with an L/P-ratio of 0.22 and 0.28 ml/g, corresponding to porosities of approximately 12% and 20%, had a 100% probability of survival until run-out of 5 million cycles, in air. When the maximum stress level, or the L/P-ratio, was increased, the probability of survival decreased. Testing in PBS at 37 degrees C led to more rapid failure of the specimens. However, the high-strength cement had a 100% probability of survival up to approximately 2.5 million cycles at a maximum compressive stress level of 10 MPa in PBS, which is substantially higher than some in vivo stress levels, e.g., those found in the spine. At 5 MPa in PBS, all specimens survived to run-out. The results found herein are important if clinical use of the material is to increase, as characterisation of the fatigue performance of CPCs is largely lacking from the literature.
  •  
44.
  •  
45.
  • Ajaxon, Ingrid, et al. (author)
  • Long-term in vitro degradation of a high-strength brushite cement in water, PBS, and serum solution
  • 2015
  • In: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141.
  • Journal article (peer-reviewed)abstract
    • Bone loss and fractures may call for the use of bone substituting materials, such as calcium phosphate cements (CPCs). CPCs can be degradable, and, to determine their limitations in terms of applications, their mechanical as well as chemical properties need to be evaluated over longer periods of time, under physiological conditions. However, there is lack of data on how the in vitro degradation affects high-strength brushite CPCs over longer periods of time, that is, longer than it takes for a bone fracture to heal. This study aimed at evaluating the long-term in vitro degradation properties of a high-strength brushite CPC in three different solutions: water, phosphate buffered saline, and a serum solution. Microcomputed tomography was used to evaluate the degradation nondestructively, complemented with gravimetric analysis. The compressive strength, chemical composition, and microstructure were also evaluated. Major changes from 10 weeks onwards were seen, in terms of formation of a porous outer layer of octacalcium phosphate on the specimens with a concomitant change in phase composition, increased porosity, decrease in object volume, and mechanical properties. This study illustrates the importance of long-term evaluation of similar cement compositions to be able to predict the material’s physical changes over a relevant time frame. 
  •  
46.
  • Ajaxon, Ingrid, et al. (author)
  • Mechanical Properties of Brushite Calcium Phosphate Cements
  • 2017
  • In: The World Scientific Encyclopedia of Nanomedicine and Bioengineering II: Bioimplants, Regenerative Medicine, and Nano-Cancer Diagnosis and Phototherapy. - Singapore : World Scientific Pte Ltd.. - 9789814667586
  • Book chapter (peer-reviewed)
  •  
47.
  •  
48.
  • Alenezi, Ali, et al. (author)
  • Development of a photon induced drug-delivery implant coating
  • 2019
  • In: Materials Science and Engineering C. - : Elsevier BV. - 0928-4931 .- 1873-0191. ; 98, s. 619-627
  • Journal article (peer-reviewed)abstract
    • A thin surface coating intended for medical devices such as implants where local drug release is enabled using near infrared light (NIR) as an external stimulus has been developed. The delivery system consists of a thin Poly (N-isopropylacrylamide)-co-acrylamide (PNIPAAm-AAm) polymer layer with incorporated gold nanorods (GNRs). The aspect ratio of the GNRs were chosen to absorb NIR light, thus fitting the biological window of low tissue absorption, to locally heat the polymeric layer to initiate a drug release. Hence, controlled drug delivery from a surface within tissue orchestrated from outside the body is achievable. Composition of the PNIPAAm-AAm co-polymer was systematically varied to find a suitable phase transition temperature for in vivo applications. Differential scanning calorimetry (DSC) analysis showed that PNIPAAm-AAm containing 10% acrylamide had an appropriate phase transition temperature of 42 °C. As visualized by scanning electron microscopy (SEM), the surface coating consisted of 200 nm uniform polymer layer. Quartz crystal microbalance with dissipation monitoring (QCM-D) analysis coupled with in situ NIR irradiation demonstrated a dramatic shift in frequency that was attributed to mass being released from the surface upon irradiation. This mass release correlated well with the drug release profile as determined using UV/VIS spectroscopy with phenol as a model drug. In addition, proof-of-concept of the drug-delivery system was demonstrated by releasing the antibiotic vancomycin to eradicate Staphylococcus epidermidis bacteria in culture.
  •  
49.
  • Alenezi, Ali, et al. (author)
  • Osseointegration effects of local release of strontium ranelate from implant surfaces in rats
  • 2019
  • In: Journal of Materials Science: Materials in Medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 30:10, s. 116-
  • Journal article (peer-reviewed)abstract
    • BACKGROUND : Numerous studies have reported the beneficial effects of strontium on bone growth, particularly by stimulating osteoblast proliferation and differentiation. Thus, strontium release around implants has been suggested as one possible strategy to enhance implant osseointegration. AIM : This study aimed to evaluate whether the local release of strontium ranelate (Sr-ranelate) from implants coated with mesoporous titania could improve bone formation around implants in an animal model. MATERIALS AND METHODS : Mesoporous titania (MT) thin coatings were formed utilizing the evaporation induced self-assembly (EISA) method using Pluronic (P123) with or without the addition of poly propylene glycol (PPG) to create materials with two different pore sizes. The MT was deposited on disks and mini-screws, both made of cp Ti grade IV. Scanning electron microscopy (SEM) was performed to characterize the MT using a Leo Ultra55 FEG instrument (Zeiss, Oberkochen, Germany). The MT was loaded with Sr-ranelate using soaking and the drug uptake and release kinetics to and from the surfaces were evaluated using quartz crystal microbalance with dissipation monitoring (QCM-D) utilizing a Q-sense E4 instrument. For the in vivo experiment, 24 adult rats were analyzed at two time points of implant healing (2 and 6 weeks). Titanium implants shaped as mini screws were coated with MT films and divided into two groups; supplied with Sr-ranelate (test group) and without Sr-ranelate (control group). Four implants (both test and control) were inserted in the tibia of each rat. The in vivo study was evaluated using histomorphometric analyses of the implant/bone interphase using optical microscopy. RESULTS : SEM images showed the successful formation of evenly distributed MT films covering the entire surface with pore sizes of 6 and 7.2 nm, respectively. The QCM-D analysis revealed an absorption of 3300 ng/cm2 of Sr-ranelate on the 7.2 nm MT, which was about 3 times more than the observed amount on the 6 nm MT (1200 ng/cm2). Both groups showed sustained release of Sr-ranelate from MT coated disks. The histomorphometric analysis revealed no significant differences in bone implant contact (BIC) and bone area (BA) between the implants with Sr-ranelate and implants in the control groups after 2 and 6 weeks of healing (BIC with a p-value of 0.43 after 2 weeks and 0.172 after 6 weeks; BA with a p-value of 0.503 after 2 weeks, and 0.088 after 6 weeks). The mean BIC and BA values within the same group showed significant increase among all groups between 2 and 6 weeks. CONCLUSION : This study could not confirm any positive effects of Sr-ranelate on implant osseointegration.
  •  
50.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-50 of 515
Type of publication
journal article (313)
conference paper (125)
doctoral thesis (24)
research review (16)
book chapter (12)
other publication (10)
show more...
patent (7)
licentiate thesis (6)
reports (1)
book (1)
show less...
Type of content
peer-reviewed (426)
other academic/artistic (80)
pop. science, debate, etc. (9)
Author/Editor
Persson, Cecilia (94)
Engqvist, Håkan (78)
Engqvist, Håkan, 197 ... (32)
Xia, Wei (26)
Andersson, Martin, 1 ... (19)
Öhman, Caroline (18)
show more...
Öhman-Mägi, Caroline (17)
Lidgren, Lars (14)
Procter, Philip (14)
Thomsen, Peter, 1953 (13)
Isaksson, Hanna (13)
Ajaxon, Ingrid (13)
Ginebra, Maria-Pau (13)
Ortiz Catalan, Max J ... (12)
Tägil, Magnus (12)
Palmquist, Anders, 1 ... (12)
Shah, Furqan A. (12)
Larsson, Sune (11)
Pujari-Palmer, Micha ... (11)
Strömme, Maria (10)
Lopez, Alejandro (10)
Karlsson Ott, Marjam (10)
Raina, Deepak Bushan (10)
Mijakovic, Ivan, 197 ... (9)
Pandit, Santosh, 198 ... (9)
Strømme, Maria, 1970 ... (9)
Pettersson, Maria (9)
Hulsart Billström, G ... (9)
Welch, Ken (8)
Skjöldebrand, Charlo ... (8)
Unosson, Erik (8)
Rising, Anna (7)
Jimbo, Ryo (7)
Xia, Wei, Associate ... (7)
Isaksson, Per (7)
Bredenberg, Susanne (7)
Lilja, Mirjam, 1981- (7)
Gatenholm, Paul, 195 ... (6)
Galli, Silvia (6)
Johansson, Jan (6)
Schmidt, Susann (6)
Wennerberg, Ann (6)
Diez-Escudero, Anna (6)
Brånemark, Rickard, ... (6)
Fu, Le (6)
Hedhammar, My (6)
Grishenkov, Dmitry, ... (6)
Joffre, Thomas (6)
Hoess, Andreas (6)
Lewin, Susanne (6)
show less...
University
Uppsala University (235)
Chalmers University of Technology (107)
Lund University (67)
Royal Institute of Technology (54)
University of Gothenburg (44)
Linköping University (32)
show more...
Karolinska Institutet (30)
RISE (21)
Malmö University (15)
Swedish University of Agricultural Sciences (15)
Umeå University (13)
University of Borås (10)
Mid Sweden University (8)
Stockholm University (7)
Linnaeus University (4)
Luleå University of Technology (3)
Mälardalen University (2)
Halmstad University (1)
University of Gävle (1)
University West (1)
Örebro University (1)
The Swedish School of Sport and Health Sciences (1)
Karlstad University (1)
show less...
Language
English (513)
Swedish (1)
Undefined language (1)
Research subject (UKÄ/SCB)
Engineering and Technology (515)
Medical and Health Sciences (176)
Natural sciences (80)
Agricultural Sciences (5)
Humanities (2)
Social Sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view